CoChat

Preliminary Evaluations of a Self-Contained Anthropomorphic Transfemoral Prosthesis

Open access
Sup, F., Varol, H.A., Mitchell, J., Withrow, T.J., Goldfarb, M. · 2009 · IEEE/ASME Transactions on Mechatronics
Cited by 298

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

This paper presents a self-contained powered knee and ankle prosthesis, intended to enhance the mobility of transfemoral amputees. A finite-state based impedance control approach, previously developed by the authors, is used for the control of the prosthesis during walking and standing. Experiments on an amputee subject for level treadmill and overground walking are described. Knee and ankle joint angle, torque, and power data taken during walking experiments at various speeds demonstrate the ability of the prosthesis to provide a functional gait that is representative of normal gait biomechanics. Measurements from the battery during level overground walking indicate that the self-contained device can provide more than 4500 strides, or 9 km, of walking at a speed of 5.1 km/h between battery charges.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmech.2009.2032688

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 19

  1. 2008, in search of the perfect battery, Economist, 386, 22
  2. 10.1109/TMECH.2006.878531 · doi:10.1109/tmech.2006.878531
  3. 10.1097/00008526-199710000-00005 · doi:10.1097/00008526-199710000-00005
  4. donath, 1974, proportional emg control for above knee prostheses, M S thesis Dept Mech Eng Massachusetts Inst Technol
  5. flowers, 1973, a man-interactive simulator system for above-knee prosthetics studies, Ph D dissertation Dept Mech Eng Massachusetts Inst Technol
  6. grimes, 1979, an active multi-mode above knee prosthesis controller, Ph D dissertation Dept Mech Eng Massachusetts Inst Technol
  7. 10.1016/0021-9290(87)90263-6 · doi:10.1016/0021-9290(87)90263-6
  8. stein, 1983, design issues in the stance phase control of above-knee prostheses, Ph D dissertation Dept Mech Eng Massachusetts Inst Technol
  9. popovic, 0, belgrade active a/k prosthesis, Electrophysiological Kinesiology, 337
  10. 10.1115/1.2168473 · doi:10.1115/1.2168473
  11. 10.1109/TMECH.2006.871097 · doi:10.1109/tmech.2006.871097
  12. 10.1016/0021-9290(95)00115-8 · doi:10.1016/0021-9290(95)00115-8
  13. 10.1016/S0021-9290(98)00094-3 · doi:10.1016/s0021-9290(98)00094-3
  14. 10.1016/0021-9290(95)00083-6 · doi:10.1016/0021-9290(95)00083-6
  15. 10.2105/AJPH.89.8.1222 · DOI
  16. bedard, 2003, actuated leg prosthesis for above-knee amputees, U S Patent 7314490
  17. klute, 2000, muscle-like pneumatic actuators for below-knee prostheses, Proc 7th Int Conf New Actuators, 289
  18. 10.1109/BIOROB.2008.4762919 · doi:10.1109/biorob.2008.4762919
  19. koniuk, 2001, self-adusting prosthetic ankle apparatus, U S Patent 6443993

Cited by

See all 298

Metadata

Authors
Sup, F., Varol, H. A., Mitchell, J., Withrow, T. J., & Goldfarb, M.
Venue
IEEE/ASME Transactions on Mechatronics
Published
2009-12
Volume
14
Issue
6
Pages
667-676
ISSN
  • 1083-4435 (ISSN-L)
  • 1941-014X
OpenAlex
W2139044388
Cited by
298
References
23
FWCI
4.85
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.