Abstract
This paper presents a self-contained powered knee and ankle prosthesis, intended to enhance the mobility of transfemoral amputees. A finite-state based impedance control approach, previously developed by the authors, is used for the control of the prosthesis during walking and standing. Experiments on an amputee subject for level treadmill and overground walking are described. Knee and ankle joint angle, torque, and power data taken during walking experiments at various speeds demonstrate the ability of the prosthesis to provide a functional gait that is representative of normal gait biomechanics. Measurements from the battery during level overground walking indicate that the self-contained device can provide more than 4500 strides, or 9 km, of walking at a speed of 5.1 km/h between battery charges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current estimates from the National Health Interview Survey.
Ss, J. (1981) · PubMed · Cited by 1,866
The biomechanics and motor control of human gait : normal, elderly and pathological
Winter, D. A. (1991) · University of Waterloo Press eBooks · Cited by 1,428
Current estimates from the National Health Interview Survey, 1990.
Adams, P. F., Hendershot, G. E., & Marano, M. A. (1987) · PubMed · Cited by 1,104
The biomechanics and motor control of human gait: Normal, elderly, and pathological
Brand, R. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90236-t · Cited by 1,103
WEIGHT, VOLUME, AND CENTER OF MASS OF SEGMENTS OF THE HUMAN BODY
Clauser, C. E., McConville, J. T., & Young, J. W. (1969) · doi:10.21236/ad0710622 · Cited by 1,020
Energy cost of walking of amputees: the influence of level of amputation.
Waters, R. L., Perry, J., Antonelli, D. J., & Hislop, H. J. (1976) · PubMed · Cited by 873
Energy cost of walking of amputees: the influence of level of amputation
Waters, R., Perry, J., Antonelli, D., & Hislop, H. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00007 · Cited by 842
The biomechanics and motor control of human gait
Winter, D. A. (1987) · University of Waterloo Press eBooks · Cited by 767
Design and Control of a Powered Transfemoral Prosthesis
Sup, F., Bohara, A., & Goldfarb, M. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364907084588 · Cited by 586
Self-citationBiomechanics of below-knee amputee gait
Winter, D. A., & Sienko, S. E. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90142-x · Cited by 521
Nadeau, S., McFadyen, B. J., & Malouin, F. (2003) · Clinical Biomechanics · doi:10.1016/s0268-0033(03)00179-7 · Cited by 366
Jacobs, R., Bobbert, M. F., & van Ingen Schenau, G. J. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00067-4 · Cited by 335
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Bellman, R. D., Holgate, M. A., & Sugar, T. G. (2008) · 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2008.4762887 · Cited by 163
Design and control of an active electrical knee and ankle prosthesis
Sup, F. C., Varol, H. A., Mitchell, J. E., Withrow, T. J., & Goldfarb, M. T. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762811 · Cited by 139
Self-citationGoldfarb, M. T., Barth, E. J., Gogola, M. A., & Wehrmeyer, J. A. (2003) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2003.812842 · Cited by 122
Self-citationTraballesi, M., Porcacchia, P., Averna, T., & Brunelli, S. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2007.01.006 · Cited by 93
Feasibility of an Active Control Scheme for Above Knee Prostheses
Grimes, D. L., Flowers, W. C., & Donath, M. (1977) · Journal of Biomechanical Engineering · doi:10.1115/1.3426293 · Cited by 92
An Electrohydraulic Knee-Torque Controller for a Prosthesis Simulator
Flowers, W. C., & Mann, R. W. (1977) · Journal of Biomechanical Engineering · doi:10.1115/1.3426266 · Cited by 91
Blumentritt, S., Scherer, H. W., Wellershaus, U., & Michael, J. W. (1997) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199701000-00005 · Cited by 66
Varol, H. A., Sup, F. C., & Goldfarb, M. T. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762860 · Cited by 54
Self-citationJoint powers in stair climbing at different slopes
Riener, R., Rabuffetti, M., & Frigo, C. (2003) · doi:10.1109/iembs.1999.802608 · Cited by 33
Proportional EMG control for above knee pros-theses.
Donath, M. (1974) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 11
Research works printed but not linked: 19
- 2008, in search of the perfect battery, Economist, 386, 22
- 10.1109/TMECH.2006.878531 · doi:10.1109/tmech.2006.878531
- 10.1097/00008526-199710000-00005 · doi:10.1097/00008526-199710000-00005
- donath, 1974, proportional emg control for above knee prostheses, M S thesis Dept Mech Eng Massachusetts Inst Technol
- flowers, 1973, a man-interactive simulator system for above-knee prosthetics studies, Ph D dissertation Dept Mech Eng Massachusetts Inst Technol
- grimes, 1979, an active multi-mode above knee prosthesis controller, Ph D dissertation Dept Mech Eng Massachusetts Inst Technol
- 10.1016/0021-9290(87)90263-6 · doi:10.1016/0021-9290(87)90263-6
- stein, 1983, design issues in the stance phase control of above-knee prostheses, Ph D dissertation Dept Mech Eng Massachusetts Inst Technol
- popovic, 0, belgrade active a/k prosthesis, Electrophysiological Kinesiology, 337
- 10.1115/1.2168473 · doi:10.1115/1.2168473
- 10.1109/TMECH.2006.871097 · doi:10.1109/tmech.2006.871097
- 10.1016/0021-9290(95)00115-8 · doi:10.1016/0021-9290(95)00115-8
- 10.1016/S0021-9290(98)00094-3 · doi:10.1016/s0021-9290(98)00094-3
- 10.1016/0021-9290(95)00083-6 · doi:10.1016/0021-9290(95)00083-6
- 10.2105/AJPH.89.8.1222 · DOI
- bedard, 2003, actuated leg prosthesis for above-knee amputees, U S Patent 7314490
- klute, 2000, muscle-like pneumatic actuators for below-knee prostheses, Proc 7th Int Conf New Actuators, 289
- 10.1109/BIOROB.2008.4762919 · doi:10.1109/biorob.2008.4762919
- koniuk, 2001, self-adusting prosthetic ankle apparatus, U S Patent 6443993
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Examples of failures discussed in the literature include inappropriate contro ller outputs due to misinterpretation of user intent or invalid sensor inputs [24,67,117,119,122,1 37,177,215,240], unstable interactions with the user and environment [60,108,139,182,185,203], actu ation failures due to”
BackgroundFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Upslope Walking With a Powered Knee and Ankle Prosthesis: Initial Results With an Amputee Subject
Sup, F., Varol, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2087360 · Cited by 283
Self-citationQuintero, D., Villarreal, D. J., Lambert, D. J., Kapp, S., & Gregg, R. D. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2794536 · Cited by 252
Control of Stair Ascent and Descent With a Powered Transfemoral Prosthesis
Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2225640 · Cited by 206
“This prosthesis is the second generation of the prosthesis prototype described in [8].”
Self-citation
Metadata
- Authors
- Sup, F., Varol, H. A., Mitchell, J., Withrow, T. J., & Goldfarb, M.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2009-12
- Volume
- 14
- Issue
- 6
- Pages
- 667-676
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2139044388
- Cited by
- 298
- References
- 23
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.