Sensor Fault-Resilient Control of Interior Permanent-Magnet Synchronous Motor Drives
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
In a conventional ac motor drive using field-oriented control, a dc-link voltage, speed, and at least two current sensors are required. Hence, in the event of sensor failure, the performance of the drive system can be severely compromised. This paper presents a sensor fault-tolerant control strategy for interior permanent-magnet synchronous motor (IPMSM) drives. Three independent observers are proposed to estimate the speed, dc-link voltage, and currents of the machine. If a sensor fault is detected, the drive system isolates the faulty sensor while retaining the remaining functional ones. The signal is then acquired from the corresponding observer in order to maintain the operation of the drive system. The experimental results provided verify the effectiveness of the proposed approach.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the case of DC-link voltage sensor fault the FTC strategy is usually based on the adaptive voltage observer [277], [278].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [278]
Citations
Cites
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 1×
“Faulty conditions and their remedial techniques in ac motor drives have been investigated extensively, but most of them deal with inverter [1]–[5] and stator or rotor winding faults [6]–[10].”
BackgroundInterior Permanent-Magnet Synchronous Motors for Adjustable-Speed Drives
Jahns, T. M., Kliman, G. B., & Neumann, T. W. (1986) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1986.4504786 · Cited by 939 · cited 1×
“The drive system is usually operated along the maximum-torque-per-ampere (MTPA) trajectory to maximize the overall efficiency [14].”
BackgroundNew Sliding-Mode Observer for Position Sensorless Control of Permanent-Magnet Synchronous Motor
Qiao, Z., Shi, T., Wang, Y., Yan, Y., Xia, C., & He, X. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2206359 · Cited by 602
Active Flux Concept for Motion-Sensorless Unified AC Drives
Boldea, I., Paicu, M. C., & Andreescu, G.-D. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002394 · Cited by 433
Rashed, M., MacConnell, P. F. A., Stronach, A. F., & Acarnley, P. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895136 · Cited by 258
Najafabadi, T. A., Salmasi, F. R., & Jabehdar-Maralani, P. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2055775 · Cited by 250 · cited 2×
“It makes sense because simultaneous failure of two or more sensors is a very rare incident probabilistically [27].”
BackgroundJeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240 · cited 2×
“Moreover, when a voltage sensor fault is identified, the nominal dc-bus voltage is used in [13].”
BackgroundPiippo, A., Hinkkanen, M., & Luomi, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911949 · Cited by 201 · cited 1×
“Furthermore, the proposed speed observer is less sensitive to speedestimation errors compared to the existing adaptive speed observers [15]–[18].”
Foo, G., & Rahman, M. F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030815 · Cited by 198 · cited 1×
“In-depth stability analysis and gain design of this observer is described in [21] and [22].”
BackgroundMultiphase Power Converter Drive for Fault-Tolerant Machine Development in Aerospace Applications
de Lillo, L., Empringham, L., Wheeler, P. W., Khwan-On, S., Gerada, C., Othman, M. N., & Huang, X. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036026 · Cited by 198 · cited 1×
“Faulty conditions and their remedial techniques in ac motor drives have been investigated extensively, but most of them deal with inverter [1]–[5] and stator or rotor winding faults [6]–[10].”
Background
Cited by
A Robust Observer-Based Sensor Fault-Tolerant Control for PMSM in Electric Vehicles
Kommuri, S. K., Defoort, M., Karimi, H. R., & Veluvolu, K. C. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2590993 · Cited by 408
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“More interesting solution, which consists in a special kind of adaptive observer of the DC-link voltage is presented in [278].”
BackgroundMethodWang, X., Wang, Z., Xu, Z., Cheng, M., Wang, W., & Hu, Y. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2876400 · Cited by 263
“In [22], three independent model-based observers are proposed to estimate the speed, dc-link voltage, and phase currents of the PMSM”
Chakraborty, C., & Verma, V. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2345337 · Cited by 209
Robust Sensors-Fault-Tolerance With Sliding Mode Estimation and Control for PMSM Drives
Kommuri, S. K., Lee, S. B., & Veluvolu, K. C. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2783888 · Cited by 140
Hang, J., Wu, H., Zhang, J., Ding, S., Huang, Y., & Hua, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3011450 · Cited by 118
Cost-Effective Three-Phase PMSM Drive Tolerant to Open-Phase Fault
Kontarcek, A., Bajec, P., Nemec, M., Ambrozic, V., & Nedeljkovic, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2437357 · Cited by 106
“Many different types of faults may occur in electrical drives: machine faults [1], various sensor faults [2], and power converter faults [3], [4].”
BackgroundWang, G., Hao, X., Zhao, N., Zhang, G., & Xu, D. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.2993950 · Cited by 99
Mwasilu, F. A., Nguyen, H. T., Choi, H. H., & Jung, J. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2632859 · Cited by 95
Current and Position Sensor Fault Diagnosis Algorithm for PMSM Drives Based on Robust State Observer
Choi, K., Kim, Y., Kim, S., & Kim, K.-S. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2992977 · Cited by 92
Zhang, G., Zhou, H., Wang, G., Li, C., & Xu, D. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2941255 · Cited by 80
Fuzzy Model Predictive Direct Torque Control of IPMSMs for Electric Vehicle Applications
Justo, J. J., Mwasilu, F. A., Kim, E., Kim, J., Choi, H. H., & Jung, J. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2665670 · Cited by 76
Open-Switch and Current Sensor Fault Diagnosis Strategy for Matrix Converter-Based PMSM Drive System
Dan, H., Yue, W., Xiong, W., Liu, Y., Su, M., & Sun, Y. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3109093 · Cited by 59
Smooth Fault-Tolerant Control of Induction Motor Drives With Sensor Failures
Liu, Y., Stettenbenz, M., & Bazzi, A. M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2848964 · Cited by 58
Sliding-Mode-Based Observer–Controller Structure for Fault-Resilient Control in DC Servomotors
Kommuri, S. K., Rath, J. J., & Veluvolu, K. C. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2721883 · Cited by 54
Current Sensorless MTPA for IPMSM Drives
Chaoui, H., Okoye, O., & Khayamy, M. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2715502 · Cited by 33
Rafaq, M. S., Mohammed, S. A. Q., & Jung, J. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2906649 · Cited by 31
Huang, G., Fukushima, E. F., She, J., Zhang, C., & He, J. (2019) · Measurement · doi:10.1016/j.measurement.2019.01.076 · Cited by 29
Youssef, A. B., Khil, S. K. E., & Slama‐Belkhodja, I. (2015) · Mathematics and Computers in Simulation · doi:10.1016/j.matcom.2015.10.005 · Cited by 27
“A similar approach is proposed in [3] where a high frequency signal injection is used for speed sensor FDI.”
BackgroundMethodMTPA based operation point speed tracking for PMSM drives without explicit current regulation
Chaoui, H., Khayamy, M., & Okoye, O. (2017) · Electric Power Systems Research · doi:10.1016/j.epsr.2017.05.019 · Cited by 23
Sensor fault-tolerant control of DFIG based wind energy conversion systems
Xiahou, K., Liu, Y., Li, M., & Wu, Q. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105563 · Cited by 23
Zhu, Q., Li, Z., Tan, X., Xie, D., & Dai, W. (2019) · Energies · doi:10.3390/en12091695 · Cited by 22
A Position Sensorless Control Strategy for PMSM Drives With Single-Phase Current Sensor
Xu, G., Xiao, F., & Lian, C. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3319367 · Cited by 21
“In [27], an EKF is employed to estimate the three-phase currents, but the accuracy of the reconstructed current is affected by the time-varying motor parameters and the motor torque has nonperiodic pulse spikes.”
MethodA Current Observer to Reduce the Sensor Count in Three-Phase PM Synchronous Machine Drives
Eull, M., Mohamadian, M., Luedtke, D., & Preindl, M. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2920804 · Cited by 21
Sensor Fault Tolerant Control in Modern and Green Power Applications: A Review
Chandra, M. V. S. S., & Mohapatro, S. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3462971 · Cited by 22
“Observer-based approaches are quite popular in this context to achieve tolerance for sensor faults. a) State observer and filter-based approaches: A multiobserver-based approach is adopted to incorporate tolerance to speed, dc-link voltage, and current sensors [50] in the interior PMSM drives.”
MethodEnergy-Efficient and Fault-Tolerant Control of Multiphase Nonsinusoidal PM Synchronous Machines
Aghili, F. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2408255 · Cited by 17
“Precise and fast torque tracking or torque regulation performance over the entire speed/torque range of the machine is highly required in some of these applications [1], whereas energy efficiency or fault tolerance becomes important in the others [2], [3].”
BackgroundYan, J., Wu, X., Zhu, Z. Q., & Liu, C. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3397960 · Cited by 14
“However, the dc-link voltage sensor may be faulty due to high humidity, high temperature, electromagnetic interference, and mechanical vibration [10], [11], [12], [13], [14], [15], [16], [17], [18], [19], [20] [24], [25], [26], [27], [28].”
BackgroundMethodThe Application of a Sliding Mode Observer in a Speed Sensor Fault Tolerant PMSM Drive System
Jankowska, K. A., Petro, V., Dybkowski, M., & Kyslan, K. (2023) · IEEE Access · doi:10.1109/access.2023.3335121 · Cited by 14
“The literature also presents solutions based on multiple observers [13], [20].”
BackgroundAli, N., & Gao, Q. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12058 · Cited by 14
Teng, Q. (2022) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2022.00036 · Cited by 13
An Optimization-Based Reduced Sensor Virtual Flux Observer for PM Synchronous Machines
Eull, M., & Preindl, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2982105 · Cited by 13
Makni, S., Bouattour, M., Hajjaji, A. E., & Chaâbane, M. A. (2021) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/acs.3231 · Cited by 12
“Replacing (13) and (14) in (9), we obtain: φ1 = I + φ1ψ1C + φ2ψ2C, (15a) φ2 = φ1ψ1 + φ2ψ2, (15b) φ3 = φ3ψ1C + φ4ψ2C, (15c) φ4 = φ3ψ1 + φ4ψ2.”
Zhang, G., Wang, G., Zhou, H., Li, C., Wang, G., & Xu, D. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8721939 · Cited by 12
Abderrezak, A., & Kidouche, M. (2016) · Journal of Power Electronics · doi:10.6113/jpe.2016.16.3.1012 · Cited by 12
“A fault in the sensors (current, speed, and DC-link voltage) can cause instability in the control loops of the system [11], [12], [18], [19].”
BackgroundWang, W., & Lu, Z. (2020) · Energies · doi:10.3390/en13020353 · Cited by 10
Open-Phase Fault Operation on Multiphase Induction Motor Drives
Guzmán, H., Gonzalez, I., Barrero, F., & Duran, M. J. (2015) · InTech eBooks · doi:10.5772/60810 · Cited by 10
Huang, G., Li, Z., Fukushima, E. F., Zhang, C., & He, J. (2019) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331219869721 · Cited by 10
“Beng et al. (2015) presented an observer method to estimate currents and offered sensor faultresilient control for an interior PMSM system.”
MethodTeng, Q., Tian, J., Duan, J., Cui, H., Zhu, J. G., & Guo, Y. G. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056033 · Cited by 9
“Over the past years, a few DC-link voltage sensorless methods have been reported in the field of grid-connected inverters and HEVs electrical drives as well as VSI-based drives [1]-[5].”
BackgroundMethodAnalysis of Steady-State Error in Torque Current Component Control of PMSM Drive
Brandštetter, P., Neborák, I., & Kuchař, M. (2017) · Advances in Electrical and Computer Engineering · doi:10.4316/aece.2017.02006 · Cited by 8
“Current research activities of scientific institutions include a sensorless control of the PMSM drives that uses different rotor speed estimation methods [12-17].”
BackgroundPermanent Magnet Synchronous Motor Control Based on Phase Current Reconstruction
Yao, G., Yang, Y., Wang, Z., & Xiao, Y. (2023) · Electronics · doi:10.3390/electronics12071624 · Cited by 6
Saha, S., & Kar, U. (2022) · Indonesian Journal of Electrical Engineering and Computer Science · doi:10.11591/ijeecs.v28.i2.pp674-685 · Cited by 5
“signal-based [7], [17], model-based [16], [18], [19] and knowledge-based [20].”
Li, Y., Huang, Y., & Xu, X. (2019) · Assembly Automation · doi:10.1108/aa-08-2018-0120 · Cited by 5
Liu, T., Mubarok, M. S., Ridwan, M. H., & Suwarno, S. (2019) · Energies · doi:10.3390/en12193593 · Cited by 5
Alzayed, M. (2022) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2022-15123 · Cited by 5
Foo, G. H. B., & Xinan, Z. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392369 · Cited by 4
A Current Observer to Reduce the Sensor Count in Three-Phase PM Synchronous Machine Drives
Eull, M., Mohamadian, M., Luedtke, D., & Preindl, M. (2018) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec.2018.8450261 · Cited by 4
Foo, G. H. B., Xinan, Z., Maskell, D. L., & Vilathgamuwa, D. M. (2015) · IEEE International Symposium on Sensorless Control for Electrical Drives (SLED) · doi:10.1109/sled.2015.7339262 · Cited by 4
Self-citationHoang, K. D., & Zhu, Z. Q. (2016) · IET International Conference on Power Electronics, Machines and Drives (PEMD) · doi:10.1049/cp.2016.0193 · Cited by 4
A robust voltage, speed and current sensors fault-tolerant control in PMSM drives
Kommuri, S. K., Lee, S. B., Park, Y., & Veluvolu, K. C. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216496 · Cited by 3
“Among the different approaches available in the literature, observer-based FD is effective and widely studied [3], [4].”
BackgroundLu, W., Wu, D., Lin, J., Lu, K., Wang, D., & Ye, M. (2019) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/0959651819892406 · Cited by 2
Integrated diagnostic system for winding fault detection of the three-phase PMSM
Otava, L., & Buchta, L. (2020) · International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT) · doi:10.1109/icumt51630.2020.9222438 · Cited by 2
“Sensor functionality of PMSM drive is discussed by autors of [7] and [8], but detection of the sensor functionality with relation to the interturn fault has not been presented yet.”
BackgroundPosition Sensor Offset Fault Diagnosis in Speed-Regulated PMSM Drives
Gamage, U. A. M., & Kuruppu, S. S. (2025) · IEEE Access · doi:10.1109/access.2025.3578189 · Cited by 1
“Beng et al. [48] propose three independent model-based observers to estimate the speed, DC-link voltage, and phase currents of the PMSM following sensor faults.”
Wang, X., Wang, Z., Wang, W., & Cheng, M. (2018) · Power Electronics and Drives · doi:10.2478/pead-2018-0012 · Cited by 1
“When the absolute difference between voltage in previous sampling period and present voltage exceeds predetermined threshold, the voltage sensor fault can be detected immediately (Foo et al., 2015).”
BackgroundFault-Tolerant Control of Speed Sensor for PMSM Based on Improved Maximum-Likelihood Voting
Dan, N., Yuan, Y., & Feng, J. (2019) · IEEE Joint International Information Technology and Artificial Intelligence Conference (ITAIC) · doi:10.1109/itaic.2019.8785874 · Cited by 1
A Speed Periodic Controller for Fault-Tolerant SPMSM Drive Systems
Ridwan, M. H., Liu, T., & Suwarno, S. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927564 · Cited by 1
Deng, Z., Yang, S., Li, Y., Gu, X., Xu, L., & Liu, R. (2024) · Automatic Control and Computer Sciences · doi:10.3103/s0146411624700032 · Cited by 1
“In [15], this paper introduces an algorithm to reconfigure the control system for IPMSM in the presence of speed, dc-link voltage, or current fault, and yet the discussion of sensor fault resilient control is made based on the assumption that only one of the sensors can be faulty during operation.”
Zhang, X. (2022) · theses.fr (ABES) · doi:10.70675/d2280d2cz2547z421bzbc33z8c99545774ab · Cited by 3
Self-citationJiménez, G., & Mauricio, H. (2015) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya)
Sliding mode based incipient sensor fault-tolerant control for DC servomotor drives
Kommuri, S. K., Rath, J. J., Shafiq, G., Gonuguntla, V., & Veluvolu, K. C. (2017) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · doi:10.1109/ecticon.2017.8096343
Voltage-Sensorless Model Predictive Current Control for Permanent-Magnet Synchronous Motor Drives
Lu, Z., Wang, W., Cheng, M., Hua, W., & Tang, C. (2019) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8921971
Enhanced Control Algorithms in Permanent Magnet Synchronous Machines
Li, H. (2020) · Lincoln (University of Nebraska)
Hu, Z., Cao, L., Song, Z., & Yao, W. (2025) · International Zhejiang Power Electronics Conference (ZPEC) · doi:10.1109/zpec67225.2025.11212956
“Luenberger observer is constructed through healthy sensor information and provide feedback based on the dq-axis current obtained from the observer in [14,15].”
Commande Tolérante aux Défauts d’un \nEntrainement Electrique à Courant Alternatif \n(MAS et MSAP)
Azzoug, Y. (2021) · University of Biskra Theses Repository (University of Biskra)
Fault diagnosis and reconstruction strategy of redundant motors and sensors in steer-by-wire system
Shi, G., Li, H., Yan, K., Wang, S., Qiao, P., & Liu, Y. (2026) · Proceedings of the Institution of Mechanical Engineers Part D Journal of Automobile Engineering · doi:10.1177/09544070251408175
Wu, Z., Ye, B., & Jin, T. (2026) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.70457
Mohan, M., & Ramesh, T. (2025) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre65581.2025.11521099
“Among these, open circuit faults are the most prevalent [14], [15].”
Metadata
- Authors
- Beng, G. F. H., Zhang, X., & Vilathgamuwa, D. M.
- Affiliations
- Nanyang Technological University (SG)
- Queensland University of Technology (AU)
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2015-04
- Volume
- 20
- Issue
- 2
- Pages
- 855-864
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W124693401
- Cited by
- 65
- References
- 27
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 3 · 2023: 3 · 2022: 5 · 2021: 3 · 2020: 7 · 2019: 14 · 2018: 4 · 2017: 9 · 2016: 4 · 2015: 7
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE/ASME Transactions on Mechatronics (publishedVersion)
- Science & Engineering Faculty
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- sensor fault-tolerant control, interior permanent magnet synchronous motor, field-oriented control, state observer, velocity estimation, current estimation, sensor fault detection, fault isolation, AC motor drives
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.