A Practical and Adaptive Method to Achieve EMG-Based Torque Estimation for a Robotic Exoskeleton
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
To improve the efficacy of robotic exoskeleton-based rehabilitation training, active joint torque of subjects should be detected. This paper presents a practical and adaptive method to estimate active joint torque using electromyography (EMG) signals for a custom lower limb robotic exoskeleton with two degrees of freedom (DOFs). This estimator, constructed of radial basis function neural networks (RBFNNs), was used to form an extended Slotine-Li controller. This extended controller eliminated the need for the calibration for EMG-torque model. The adaptive control of exoskeleton and adaptive estimation of active joint torque were performed within the same framework. By introducing a two-step learning strategy into the controller, the estimator can continuously adapt to changes in the EMG-torque model, and overcome the problems due to the time-varying property of EMG signals. Simulation and experimental results show that the presented estimator can predict the active joint torque of subjects in a practical and adaptive manner. Additionally, the accurate movement control of exoskeleton is also guaranteed. At present, the experiments are conducted only for the swing phase due to the lack of the force plate sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Slotine, J.-J. E., & Li, W. (1991) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,975
On the Adaptive Control of Robot Manipulators
Slotine, J.-J. E., & Li, W. (1987) · The International Journal of Robotics Research · doi:10.1177/027836498700600303 · Cited by 2,284
An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo
Lloyd, D. G., & Besier, T. F. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00010-1 · Cited by 1,199 · cited 4×
“In [20], the overall model is composed of an anatomical model, an EMG-to-activation model, a Hill-type muscle model, and model calibration.”
BackgroundMethodInfluentialReview of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992 · cited 2×
“trode displacement, sweat under the electrode, and so on [27].”
BackgroundElectromechanical delay in human skeletal muscle under concentric and eccentric contractions
Cavanagh, P. R., & Komi, P. V. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00431022 · Cited by 802 · cited 1×
“muscle contraction, preceding the corresponding joint torque by 20∼100 ms [16].”
BackgroundPatient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729 · cited 2×
“Commercial lower limb robotic exoskeleton systems have been developed, including Lokomat (Hocoma, Switzerland) [2] and Gait Trainer (Reha-Stim, German) [3].”
MethodMotor learning elicited by voluntary drive
Lotze, M. (2003) · Brain · doi:10.1093/brain/awg079 · Cited by 691 · cited 2×
“This reduces the energy consumption and neuromuscular activity, which decreases the rehabilitation efficacy [7].”
BackgroundAn EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531 · cited 5×
“In [19], a neurofuzzy modifier was constructed to approximate the joint torque of upper limbs based”
BackgroundMethodInfluentialA myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437 · cited 2×
“and higher signal-to-noise ratio than mechanical torque signals [17], [18].”
BackgroundLocomotor activity in spinal man
Dietz, V, Colombo, G., & Jensen, L. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90751-x · Cited by 395 · cited 1×
“Traditionally, gait training has been manually assisted by therapists, but therapists have often suffered from the labor-intensive training [1].”
BackgroundA mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Identification of passive elastic joint moments in the lower extremities
Riener, R., & Edrich, T. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00009-3 · Cited by 321 · cited 2×
“torque components, such as gravity torque, friction torque, inertial torque, and also passive joint torque of subjects [13]–[15].”
BackgroundSpeed dependence of averaged EMG profiles in walking
Hof, A. L., Elzinga, H., Grimmius, W., & Halbertsma, J. P. K. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00206-5 · Cited by 313 · cited 2×
“Normally, the scope for cutoff frequency of the filter is 3∼25 Hz [26].”
BackgroundLee, S., & Sankai, Y. (2003) · IEEE/RSJ International Conference on Intelligent Robots and System · doi:10.1109/irds.2002.1043967 · Cited by 291 · cited 2×
“It has been established that RBFNNs can approach any nonlinear function with enough neurons, and therefore perform better than some simplified EMG-torque models [31] and nonlinear EMG-torque models [13].”
BackgroundHigh-Precision Robust Force Control of a Series Elastic Actuator
Oh, S., & Kong, K. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2614503 · Cited by 278 · cited 1×
“[12].”
Minimal Assist-as-Needed Controller for Upper Limb Robotic Rehabilitation
Pehlivan, A. U., Losey, D. P., & O'Malley, M. K. (2016) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2503726 · Cited by 275
An EMG-Based Robot Control Scheme Robust to Time-Varying EMG Signal Features
Artemiadis, P. K., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2040832 · Cited by 224 · cited 1×
“model is indeterministic and needs to be recalibrated frequently [25].”
BackgroundSwinnen, E., Duerinck, S., Baeyens, J., Meeusen, R., & Kerckhofs, E. (2010) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0538 · Cited by 207 · cited 1×
“However, for subacute patients with some motor abilities, the training paradigm of the “first-generation” exoskeletons cannot provide better rehabilitation efficacy than that of manually assisted treadmill gait training or manually assisted overground training [5].”
BackgroundRecent trends in assistive technology for mobility
Cowan, R. E., Fregly, B. J., Boninger, M. L., Chan, L., Rodgers, M. M., & Reinkensmeyer, D. J. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-20 · Cited by 194
An exoskeletal robot for human shoulder joint motion assist
Kiguchi, K., Iwami, K., Yasuda, M., Watanabe, K., & Fukuda, T. (2003) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2003.809168 · Cited by 191 · cited 2×
“Because the EMG-torque model is highly nonlinear by nature, it is burdensome to calibrate [19], [24].”
BackgroundMethodStaudenmann, D., Kingma, I., Daffertshofer, A., Stegeman, D. F., & vanDieen, J. H. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870246 · Cited by 172 · cited 1×
“High-density EMG could be a good alternative way to fully collect the EMG signals around a joint [27], [36], [37], and thus”
BackgroundGui, K., Liu, H., & Zhang, D. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2703586 · Cited by 120 · cited 2×
“The length between the knee and hip joints can be adjusted by a leading screw and nut mechanism, conforming to the requirements of users [30].”
BackgroundSelf-citationPan, L., Zhang, D., Jiang, N., Sheng, X., & Zhu, X. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0102-9 · Cited by 115 · cited 1×
“High-density EMG could be a good alternative way to fully collect the EMG signals around a joint [27], [36], [37], and thus”
BackgroundSelf-citationDesign of a Parallel Actuated Exoskeleton for Adaptive and Safe Robotic Shoulder Rehabilitation
Hsieh, H.-C., Chen, D.-F., Li, C., & Lan, C.-C. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2717874 · Cited by 113 · cited 1×
“information under the deformation of sensitive devices [11],”
BackgroundRobotic training and spinal cord plasticity
Edgerton, V. R., & Roy, R. R. (2008) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2008.09.018 · Cited by 112 · cited 1×
“In addition, most “first-generation” exoskeleton systems only focus on position tracking performance and provide monotonous assistance, but neglect the patients voluntary contribution [6].”
BackgroundChen, S., Chen, Z., Yao, B., Zhu, X., Zhu, S., Wang, Q., & Song, Y. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2614987 · Cited by 79 · cited 1×
“torque of subjects or interaction torque between subjects and exoskeletons [9], [10].”
BackgroundA Method to Accurately Estimate the Muscular Torques of Human Wearing Exoskeletons by Torque Sensors
Hwang, B., & Jeon, D. (2015) · Sensors · doi:10.3390/s150408337 · Cited by 79 · cited 10×
“It could be expected that the accuracy of the estimator in the two studies would be lower than that of the elaborately calibrated estimator in [13].”
BackgroundMethodInfluentialChen, X., Zeng, Y., & Yin, Y. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2582321 · Cited by 76 · cited 1×
“In [33], the EMG signals of QF and BF muscles were acquired.”
BackgroundWang, W., Hou, Z., Cheng, L., Tong, L., Peng, L., Peng, L., & Tan, M. (2016) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2016.2531653 · Cited by 48 · cited 2×
“gravity torque, and passive torque), it is a burdensome process to totally identify the active joint torque from the mechanical sensors [13], [14].”
BackgroundDesign of a Myoelectric Transhumeral Prosthesis
Bennett, D. A., Mitchell, J. E., Truex, D., & Goldfarb, M. T. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2552999 · Cited by 46 · cited 1×
“and higher signal-to-noise ratio than mechanical torque signals [17], [18].”
BackgroundThe natural frequency-based power assist control for lower body with HAL-3
Lee, S., & Sankai, Y. (2003) · SMC'03 Conference Proceedings. 2003 IEEE International Conference on Systems, Man and Cybernetics. Conference Theme - System Security and Assurance (Cat. No.03CH37483) · doi:10.1109/icsmc.2003.1244648 · Cited by 41 · cited 2×
“The famous robotic exoskeletons, hybrid assistive leg (Cyberdyne, Japan), utilized EMG to estimate active joint torque and achieve impedance control for subjects [23].”
BackgroundHwang, B., & Jeon, D. (2018) · International Journal of Control Automation and Systems · doi:10.1007/s12555-016-0545-1 · Cited by 27
Aliakbaryhosseinabadi, S., Jiang, N., Vučković, A., Dremstrup, K., Farina, D., & Mrachacz‐Kersting, N. (2015) · Brain-Computer Interfaces · doi:10.1080/2326263x.2015.1053301 · Cited by 17
Self-learning assistive exoskeleton with sliding mode admittance control
Huang, T.-H., Cheng, C.-A., & Huang, H.-P. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696427 · Cited by 15 · cited 2×
“In [32], the active torque was overestimated”
MethodEMG-Torque correction on Human Upper extremity using Evolutionary Computation
Veronica, J. L., Parasuraman, S., Khan, M. K. A. A., & DSingh, K. J. (2016) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/149/1/012152 · Cited by 4 · cited 1×
“In [22], Veronica et al.”
Cited by
A review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
Metadata
- Authors
- Gui, K., Liu, H., & Zhang, D.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2019-04
- Volume
- 24
- Issue
- 2
- Pages
- 483-494
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2910932367
- Cited by
- 169
- References
- 36
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.