The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Validation of nonrigid image registration using finite-element methods: application to breast MR images
Open accessAbstract
This paper presents a novel method for validation of nonrigid medical image registration. This method is based on the simulation of physically plausible, biomechanical tissue deformations using finite-element methods. Applying a range of displacements to finite-element models of different patient anatomies generates model solutions which simulate gold standard deformations. From these solutions, deformed images are generated with a range of deformations typical of those likely to occur in vivo. The registration accuracy with respect to the finite-element simulations is quantified by co-registering the deformed images with the original images and comparing the recovered voxel displacements with the biomechanically simulated ones. The functionality of the validation method is demonstrated for a previously described nonrigid image registration technique based on free-form deformations using B-splines and normalized mutual information as a voxel similarity measure, with an application to contrast-enhanced magnetic resonance mammography image pairs. The exemplar nonrigid registration technique is shown to be of subvoxel accuracy on average for this particular application. The validation method presented here is an important step toward more generic simulations of biomechanically plausible tissue deformations and quantification of tissue motion recovery using nonrigid image registration. It will provide a basis for improving and comparing different nonrigid registration techniques for a diversity of medical applications, such as intrasubject tissue deformation or motion correction in the brain, liver or heart.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationA survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Self-citationSCHROEDER, W. J., & MARTIN, K. M. (2005) · Visualization Handbook · doi:10.1016/b978-012387582-2/50032-0 · Cited by 1,355
Hamming, R. W., & Stearns, S. D. (1977) · Cited by 1,275
Scattered data interpolation with multilevel B-splines
Lee, S., Wolberg, G., & Shin, S. Y. (1997) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.620490 · Cited by 1,046
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationMedical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675
Self-citationA survey of hierarchical non-linear medical image registration
Lester, H., & Arridge, S. R. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00095-8 · Cited by 484
High-resolution tensor MR elastography for breast tumour detection
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/317 · Cited by 481
Hajnal, J. V., & Hill, D. (2001) · Lecture notes in computer science · doi:10.1007/978-3-032-25169-5 · Cited by 402
Self-citationSchnabel, J. A., Rueckert, D., Quist, M., Blackall, J. M., Castellano-Smith, A. D., Hartkens, T., Penney, G. P., Hall, W. A., Liu, H., Truwit, C. L., et al. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-45468-3_69 · Cited by 355
Self-citationPlewes, D. B., Bishop, J., Samani, A., & Sciarretta, J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/314 · Cited by 318
Voxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Self-citationComparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269
Self-citationEvaluation of an iterative reconstruction method for quantitative elastography
Doyley, M. M., Meaney, P. M., & Bamber, J. C. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/309 · Cited by 251
Voxel Similarity Measures for 3D Serial MR Brain Image Registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., & Hawkes, D. J. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_48 · Cited by 246
Self-citationBiomechanical 3-D finite element modeling of the human breast using MRI data
Samani, A., Bishop, J., Yaffe, M. J., & Plewes, D. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.921476 · Cited by 217
Automatic Construction of 3D Statistical Deformation Models Using Non-rigid Registration
Rueckert, D., Frangi, A. F., & Schnabel, J. A. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_10 · Cited by 155
Self-citationVisual assessment of the accuracy of retrospective registration of MR and CT images of the brain
Fitzpatrick, J. M., Hill, D., Shyr, Y., West, J. B., Studholme, C., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730402 · Cited by 140
Self-citationComparison and Evaluation of Rigid, Affine, and Nonrigid Registration of Breast MR Images
Denton, E., Sonoda, L. I., Rueckert, D., Rankin, S., Hayes, C., Leach, M. O., Hill, D., & Hawkes, D. J. (1999) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199909000-00031 · Cited by 124
Self-citationRegistration of 3D Intraoperative MR Images of the Brain Using a Finite Element Biomechanical Model
Ferrant, M., Warfield, S. K., Nabavi, A., Jolesz, F. A., & Kikinis, R. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_3 · Cited by 93
Tanner, C., Schnabel, J. A., Chung, D. H., Clarkson, M. J., Rueckert, D., Hill, D., & Hawkes, D. J. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_33 · Cited by 89
Self-citationConstructing Patient Specific Models for Correcting Intraoperative Brain Deformation
Castellano-Smith, A. D., Hartkens, T., Schnabel, J. A., Hose, D. R., Liu, H., Hall, W. A., Truwit, C. L., Hawkes, D. J., & Hill, D. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_130 · Cited by 60
Self-citationRohr, K., Fornefett, M., & Stiehl, H. S. (1999) · Lecture notes in computer science · doi:10.1007/3-540-48714-x_19 · Cited by 59
Tanner, C., Schnabel, J., Degenhard, A., Castellano-Smith, A. D., Hayes, C., Leach, M., Hose, D., Hill, D., & Hawkes, D. (2002) · International Conference on Medical Image Computing and Computer-Assisted Intervention · doi:10.1007/3-540-45786-0_38 · Cited by 51
Self-citationDetecting Failure, Assessing Success
Fitzpatrick, J. M. (2001) · Biomedical engineering series · doi:10.1201/9781420042474.ch6 · Cited by 44
Detecting Failure, Assessing Success
Hajnal, J. V., & Hill, D. (2001) · doi:10.1201/9781420042474-9 · Cited by 4
Self-citation
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Self-citationSamani, A., Zubovits, J., & Plewes, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/002 · Cited by 707
Image-Guided Interventions: Technology Review and Clinical Applications
Cleary, K., & Peters, T. M. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105249 · Cited by 453
Metadata
- Authors
- Schnabel, J. A., Tanner, C., Castellano-Smith, A. D., Degenhard, A., Leach, M. O., Hose, D. R., Hill, D. L. G., & Hawkes, D. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-02
- Volume
- 22
- Issue
- 2
- Pages
- 238-247
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2127374940
- Cited by
- 255
- References
- 30
- FWCI
- 15.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.