The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Optimal Wavelet Transform for the Detection of Microaneurysms in Retina Photographs
Open accessAbstract
In this paper, we propose an automatic method to detect microaneurysms in retina photographs. Microaneurysms are the most frequent and usually the first lesions to appear as a consequence of diabetic retinopathy. So, their detection is necessary for both screening the pathology and follow up (progression measurement). Automating this task, which is currently performed manually, would bring more objectivity and reproducibility. We propose to detect them by locally matching a lesion template in subbands of wavelet transformed images. To improve the method performance, we have searched for the best adapted wavelet within the lifting scheme framework. The optimization process is based on a genetic algorithm followed by Powell's direction set descent. Results are evaluated on 120 retinal images analyzed by an expert and the optimal wavelet is compared to different conventional mother wavelets. These images are of three different modalities: there are color photographs, green filtered photographs, and angiographs. Depending on the imaging modality, microaneurysms were detected with a sensitivity of respectively 89.62%, 90.24%, and 93.74% and a positive predictive value of respectively 89.50%, 89.75%, and 91.67%, which is better than previously published methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Genetic algorithms in search, optimization, and machine learning
(1989) · Choice Reviews Online · doi:10.5860/choice.27-0936 · Cited by 49,010
Genetic Algorithms in Search, Optimization and Machine Learning
Goldberg, D. E., & Robson, D. (1988) · Cited by 18,391
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 11,811
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Entropy-based algorithms for best basis selection
Coifman, R. R., & Wickerhauser, M. V. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119732 · Cited by 3,188
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
The Lifting Scheme: A Custom-Design Construction of Biorthogonal Wavelets
Sweldens, W. (1996) · Applied and Computational Harmonic Analysis · doi:10.1006/acha.1996.0015 · Cited by 2,213
Translation-Invariant De-Noising
Coifman, R. R., & Donoho, D. L. (1995) · Lecture Notes in Statistics · doi:10.1007/978-1-4612-2544-7_9 · Cited by 1,914
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation
Zana, F., & Klein, J.-C. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.931095 · Cited by 862
Klein, R., Klein, B. E. K., & Moss, S. E. (1984) · Ophthalmology · doi:10.1016/s0161-6420(84)34337-8 · Cited by 595
Automated detection of diabetic retinopathy on digital fundus images
Sinthanayothin, C., Boyce, J. F., Williamson, T. H., Cook, H. L., Mensah, E., Lal, S., & Usher, D. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00613.x · Cited by 509
Automatic detection of red lesions in digital color fundus photographs
Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. A., & Abramoff, M. D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.843738 · Cited by 504
Lee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932744 · Cited by 457
Retinopathy and Vision Loss in Insulin-dependent Diabetes in Europe
Sjølie, A. K., Stephenson, J., Aldington, S., Kohner, E., Janka, H., Stevens, L., Fuller, J., Karamanos, B., Tountas, C., Kofinis, A., et al. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30327-3 · Cited by 216
Ege, B. M., Hejlesen, O. K., Larsen, O. V., Møller, K., Jennings, B., Kerr, D., & Cavan, D. A. (2000) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00065-1 · Cited by 214
The 25-Year Incidence of Visual Impairment in Type 1 Diabetes Mellitus
Klein, R., Lee, K. E., Gangnon, R. E., & Klein, B. E. K. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2009.06.051 · Cited by 181
Teng, T., Lefley, M., & Claremont, D. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347689 · Cited by 179
Hipwell, J. H., Strachan, F., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V. (2000) · Diabetic Medicine · doi:10.1046/j.1464-5491.2000.00338.x · Cited by 177
Adaptive wavelet transforms via lifting
Claypoole, R. L., Baraniuk, R. G., & Nowak, R. D. (2002) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1998.681737 · Cited by 153
Cost Savings Associated with Detection and Treatment of Diabetic Eye Disease
Javitt, J. C. (1995) · PharmacoEconomics · doi:10.2165/00019053-199500081-00008 · Cited by 39
Genetic algorithm wavelet design for signal classification
Jones, E., Runkle, P. R., Dasgupta, N., Couchman, L. S., & Carin, L. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.946991 · Cited by 39
Cited by
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Automated Identification of Diabetic Retinopathy Using Deep Learning
Gargeya, R., & Leng, T. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.02.008 · Cited by 1,362
Krause, J., Gulshan, V., Rahimy, E., Karth, P., Widner, K., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.034 · Cited by 564
Niemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Self-citation
Metadata
- Authors
- Quellec, G., Lamard, M., Josselin, P. M., Cazuguel, G., Cochener, B., & Roux, C.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-09
- Volume
- 27
- Issue
- 9
- Pages
- 1230-1241
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2149430368
- Cited by
- 343
- References
- 25
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.