The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Transfer Learning Improves Supervised Image Segmentation Across Imaging Protocols
Open accessAbstract
The variation between images obtained with different scanners or different imaging protocols presents a major challenge in automatic segmentation of biomedical images. This variation especially hampers the application of otherwise successful supervised-learning techniques which, in order to perform well, often require a large amount of labeled training data that is exactly representative of the target data. We therefore propose to use transfer learning for image segmentation. Transfer-learning techniques can cope with differences in distributions between training and target data, and therefore may improve performance over supervised learning for segmentation across scanners and scan protocols. We present four transfer classifiers that can train a classification scheme with only a small amount of representative training data, in addition to a larger amount of other training data with slightly different characteristics. The performance of the four transfer classifiers was compared to that of standard supervised classification on two magnetic resonance imaging brain-segmentation tasks with multi-site data: white matter, gray matter, and cerebrospinal fluid segmentation; and white-matter-/MS-lesion segmentation. The experiments showed that when there is only a small amount of representative training data available, transfer learning can greatly outperform common supervised-learning approaches, minimizing classification errors by up to 60%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Pan, S. J., & Yang, Q. (2010) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2009.191 · Cited by 23,387
A decision-theoretic generalization of on-line learning and an application to boosting
Freund, Y., & Schapire, R. E. (1997) · Journal of Computer and System Sciences · doi:10.1006/jcss.1997.1504 · Cited by 20,466
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Learning with Kernels: Support Vector Machines, Regularization, Optimization, and Beyond
Schölkopf, B., & Smola, A. J. (2001) · The MIT Press eBooks · doi:10.7551/mitpress/4175.001.0001 · Cited by 11,703
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · cited 3×
“In Table I we compared our WM/GM/CSF segmentations to segmentations obtained with SPM8 [3], a state-of-the-art brain-tissue segmentation tool.”
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“All images were corrected for nonuniformity using the N4 method [30], and basic image normalization was performed by a range-matching procedure that scaled the intensities such that the voxels between the fourth and the 96th percentage in intensity within the brain mask were mapped between zero and one.”
Method
Cited by
A Review of Domain Adaptation without Target Labels
Kouw, W. M., & Loog, M. (2021) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2019.2945942 · Cited by 613
Unsupervised Domain Adaptation in Brain Lesion Segmentation with Adversarial Networks
Kamnitsas, K., Baumgartner, C., Ledig, C., Newcombe, V., Simpson, J., Kane, A., Menon, D., Nori, A., Criminisi, A., Rueckert, D., et al. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-59050-9_47 · Cited by 468
Artificial intelligence and machine learning for medical imaging: A technology review
Barragán-Montero, A., Javaid, U., Valdés, G., Nguyen, D., Desbordes, P., Macq, B., Willems, S., Vandewinckele, L., Holmström, M., Löfman, F., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.04.016 · Cited by 450
Chen, C., Dou, Q., Chen, H., Qin, J., & Heng, P. A. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2972701 · Cited by 441
Muhammad, K., Khan, S., Ser, J. D., & Albuquerque, V. H. C. D. (2021) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2020.2995800 · Cited by 398
Machine learning and deep learning approach for medical image analysis: diagnosis to detection
Rana, M., & Bhushan, M. (2023) · Multimedia Tools and Applications · doi:10.1007/s11042-022-14305-w · Cited by 365
Machine learning approaches in medical image analysis: From detection to diagnosis
de Bruijne, M. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.06.032 · Cited by 347
Self-citationChen, C., Dou, Q., Chen, H., Qin, J., & Heng, P.-A. (2019) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v33i01.3301865 · Cited by 336
Lymph node metastasis prediction of papillary thyroid carcinoma based on transfer learning radiomics
Yu, J., Deng, Y., Liu, T., Zhou, J., Jia, X., Xiao, T., Zhou, S., Li, J., Guo, Y., Wang, Y., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18497-3 · Cited by 323
MS-Net: Multi-Site Network for Improving Prostate Segmentation With Heterogeneous MRI Data
Liu, Q., Dou, Q., Yu, L., & Heng, P. A. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2974574 · Cited by 308
Unsupervised Reverse Domain Adaptation for Synthetic Medical Images via Adversarial Training
Mahmood, F., Chen, R., & Durr, N. J. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2842767 · Cited by 257
“There is a growing interest in transferring knowledge from networks trained for conventional vision to the medical imaging domain [7], [23]–[26].”
BackgroundTransfer Learning for Domain Adaptation in MRI: Application in Brain Lesion Segmentation
Ghafoorian, M., Mehrtash, A., Kapur, T., Karssemeijer, N., Marchiori, E., Pesteie, M., Guttmann, C. R. G., de Leeuw, F.-E., Tempany, C. M., van Ginneken, B., et al. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66179-7_59 · Cited by 253
Deep convolutional neural network for segmentation of knee joint anatomy
Zhou, Z., Zhao, G., Kijowski, R., & Liu, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27229 · Cited by 202
Transfer learning in magnetic resonance brain imaging: a systematic review
Valverde, J. M., Imani, V., Abdollahzadeh, A., De Feo, R., Prakash, M., Ciszek, R., & Tohka, J. (2021) · Journal of Imaging · doi:10.3390/jimaging7040066 · Cited by 137
Cheplygina, V., de Bruijne, M., & Pluim, J. P. W. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.03.009 · Cited by 93
Self-citationRadiology and multi-scale data integration for precision oncology
Paverd, H., Zormpas-Petridis, K., Clayton, H., Burge, S., & Crispin-Ortuzar, M. (2024) · npj Precision Oncology · doi:10.1038/s41698-024-00656-0 · Cited by 41
Qiao, S., Pan, S., Luo, G., Pang, S., Chen, T., Singh, A. K., & Lv, Z. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3143319 · Cited by 32
Azizi, S., Mousavi, P., Yan, P., Tahmasebi, A., Kwak, J. T., Xu, S., Turkbey, B., Choyke, P., Pinto, P., Wood, B., et al. (2017) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-017-1573-x · Cited by 30
Jahanifar, M., Tajeddin, N. Z., Koohbanani, N. A., Gooya, A., & Rajpoot, N. (2018) · arXiv · doi:10.48550/arxiv.1809.10243 · Cited by 21
Metadata
- Authors
- van Opbroek, A., Ikram, M. A., Vernooij, M. W., & de Bruijne, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2015-05
- Volume
- 34
- Issue
- 5
- Pages
- 1018-1030
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2094286293
- Cited by
- 253
- References
- 42
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.