The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Adaptive Spatiotemporal SVD Clutter Filtering for Ultrafast Doppler Imaging Using Similarity of Spatial Singular Vectors
Open accessAbstract
Singular value decomposition of ultrafast imaging ultrasonic data sets has recently been shown to build a vector basis far more adapted to the discrimination of tissue and blood flow than the classical Fourier basis, improving by large factor clutter filtering and blood flow estimation. However, the question of optimally estimating the boundary between the tissue subspace and the blood flow subspace remained unanswered. Here, we introduce an efficient estimator for automatic thresholding of subspaces and compare it to an exhaustive list of thirteen estimators that could achieve this task based on the main characteristics of the singular components, namely the singular values, the temporal singular vectors, and the spatial singular vectors. The performance of those fourteen estimators was tested in vitro in a large set of controlled experimental conditions with different tissue motion and flow speeds on a phantom. The estimator based on the degree of resemblance of spatial singular vectors outperformed all others. Apart from solving the thresholding problem, the additional benefit with this estimator was its denoising capabilities, strongly increasing the contrast to noise ratio and lowering the noise floor by at least 5 dB. This confirms that, contrary to conventional clutter filtering techniques that are almost exclusively based on temporal characteristics, efficient clutter filtering of ultrafast Doppler imaging cannot overlook space. Finally, this estimator was applied in vivo on various organs (human brain, kidney, carotid, and thyroid) and showed efficient clutter filtering and noise suppression, improving largely the dynamic range of the obtained ultrafast power Doppler images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 6,921
DISTRIBUTION OF EIGENVALUES FOR SOME SETS OF RANDOM MATRICES
Marčenko, V. A., & Pastur, L. A. (1967) · Mathematics of the USSR-Sbornik · doi:10.1070/sm1967v001n04abeh001994 · Cited by 1,713
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Self-citationDemene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Self-citationFunctional ultrasound imaging of the brain
Macé, E., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 751
Self-citationOtazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Functional ultrasound imaging of the brain: theory and basic principles
Mace, E., Montaldo, G., Osmanski, B.-F., Cohen, I., Fink, M., & Tanter, M. (2013) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2592 · Cited by 327
Self-citationClutter filter design for ultrasound color flow imaging
Bjaerum, S., Torp, H., & Kristoffersen, K. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.985705 · Cited by 257
Unbiased Risk Estimates for Singular Value Thresholding and Spectral Estimators
Candes, E. J., Sing-Long, C. A., & Trzasko, J. D. (2013) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2270464 · Cited by 243
Eigen-based clutter filter design for ultrasound color flow imaging: a review
Yu, A., & Lovstakken, L. (2010) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1521 · Cited by 204
Osmanski, B.-F., Pezet, S., Ricobaraza, A., Lenkei, Z., & Tanter, M. (2014) · Nature Communications · doi:10.1038/ncomms6023 · Cited by 175
Self-citationEEG and functional ultrasound imaging in mobile rats
Sieu, L.-A., Bergel, A., Tiran, E., Deffieux, T., Pernot, M., Gennisson, J.-L., Tanter, M., & Cohen, I. (2015) · Nature Methods · doi:10.1038/nmeth.3506 · Cited by 158
Self-citation4D microvascular imaging based on ultrafast Doppler tomography
Demené, C., Tiran, E., Sieu, L.-A., Bergel, A., Gennisson, J. L., Pernot, M., Deffieux, T., Cohen, I., & Tanter, M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.014 · Cited by 139
Self-citationMauldin, F. W., Lin, D., & Hossack, J. A. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2160075 · Cited by 133
Tiran, E., Ferrier, J., Deffieux, T., Gennisson, J., Pezet, S., Lenkei, Z., & Tanter, M. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.03.011 · Cited by 129
Self-citationClutter filters adapted to tissue motion in ultrasound color flow imaging
Bjærum, S., Torp, H. G., & Kristoffersen, K. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1009328 · Cited by 123
Ledoux, L. A. F., Brands, P. J., & Hoeks, A. P. G. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900101 · Cited by 121
Walker, W. F., & Trahey, G. E. (1994) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.308499 · Cited by 113
Ultrafast Doppler Reveals the Mapping of Cerebral Vascular Resistivity in Neonates
Demené, C., Pernot, M., Biran, V., Alison, M., Fink, M., Baud, O., & Tanter, M. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.49 · Cited by 109
Self-citationKruse, D. E., & Ferrara, K. W. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041080 · Cited by 97
Ultrafast Doppler Imaging of Blood Flow Dynamics in the Myocardium
Osmanski, B.-F., Pernot, M., Montaldo, G., Bel, A., Messas, E., & Tanter, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203316 · Cited by 95
Self-citationReal-time adaptive clutter rejection filtering in color flow imaging using power method iterations
Løvstakken, L., Bjærum, S., Kristoffersen, K., Haaverstad, R., & Torp, H. G. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1678188 · Cited by 80
In vivo real-time cavitation imaging in moving organs
Arnal, B., Baranger, J., Demené, C., Tanter, M., & Pernot, M. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa4fe8 · Cited by 37
Self-citationOsmanski, B.-F., Lecarpentier, É., Montaldo, G., Tsatsaris, V., Chavatte‐Palmer, P., & Tanter, M. (2015) · Scientific Reports · doi:10.1038/srep13394 · Cited by 31
Self-citation
Metadata
- Authors
- Baranger, J., Arnal, B., Perren, F., Baud, O., Tanter, M., & Demene, C.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2018-07
- Volume
- 37
- Issue
- 7
- Pages
- 1574-1586
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2793842820
- Cited by
- 348
- References
- 24
- FWCI
- 17.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.