CoreDiff: Contextual Error-Modulated Generalized Diffusion Model for Low-Dose CT Denoising and Generalization
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Low-dose computed tomography (CT) images suffer from noise and artifacts due to photon starvation and electronic noise. Recently, some works have attempted to use diffusion models to address the over-smoothness and training instability encountered by previous deep-learning-based denoising models. However, diffusion models suffer from long inference time due to a large number of sampling steps involved. Very recently, cold diffusion model generalizes classical diffusion models and has greater flexibility. Inspired by cold diffusion, this paper presents a novel COntextual eRror-modulated gEneralized Diffusion model for low-dose CT (LDCT) denoising, termed CoreDiff. First, CoreDiff utilizes LDCT images to displace the random Gaussian noise and employs a novel mean-preserving degradation operator to mimic the physical process of CT degradation, significantly reducing sampling steps thanks to the informative LDCT images as the starting point of the sampling process. Second, to alleviate the error accumulation problem caused by the imperfect restoration operator in the sampling process, we propose a novel ContextuaL Error-modulAted Restoration Network (CLEAR-Net), which can leverage contextual information to constrain the sampling process from structural distortion and modulate time step embedding features for better alignment with the input at the next time step. Third, to rapidly generalize the trained model to a new, unseen dose level with as few resources as possible, we devise a one-shot learning framework to make CoreDiff generalize faster and better using only one single LDCT image (un)paired with normal-dose CT (NDCT). Extensive experimental results on four datasets demonstrate that our CoreDiff outperforms competing methods in denoising and generalization performance, with clinically acceptable inference time. Source code is made available at https://github.com/qgao21/CoreDiff.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-Resolution Image Synthesis with Latent Diffusion Models
Rombach, R., Blattmann, A., Lorenz, D., Esser, P., & Ommer, B. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.01042 · Cited by 20,302 · cited 1×
“Examples include latent space sampling technology employed by stable diffusion [63] and the knowledge distillation technology utilized by consistency models [64].”
Method$rm K$-SVD: An Algorithm for Designing Overcomplete Dictionaries for Sparse Representation
Aharon, M., Elad, M., & Bruckstein, A. (2006) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2006.881199 · Cited by 9,451
Denoising Diffusion Probabilistic Models
Ho, J., Jain, A., & Abbeel, P. (2020) · arXiv · doi:10.48550/arxiv.2006.11239 · Cited by 8,712
FSIM: A Feature Similarity Index for Image Quality Assessment
Zhang, L., Zhang, L., Mou, X., & Zhang, D. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2109730 · Cited by 5,203 · cited 1×
“In addition, we also used three new objective IQA metrics, i . e . feature similarity index (FSIM) [53], visual information fidelity (VIF) [54], and noise quality metric (NQM) [55], which have demonstrated improved alignment with subjective assessments made by radiologists on medical images [56].”
MethodArbitrary Style Transfer in Real-Time with Adaptive Instance Normalization
Huang, X., & Belongie, S. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.167 · Cited by 5,076 · cited 1×
“Specifically, our EMM is a feature-wise linear modulation module [38], [39], [40] to modulate the time step embedding features, in which the modulation factors at time step t − 1 are estimated as follows : where F φ ( · ) is a shallow network parameterized by φ to estimate the modulation factors…”
MethodImage information and visual quality
Sheikh, H. R., & Bovik, A. C. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.859378 · Cited by 4,104 · cited 1×
“In addition, we also used three new objective IQA metrics, i . e . feature similarity index (FSIM) [53], visual information fidelity (VIF) [54], and noise quality metric (NQM) [55], which have demonstrated improved alignment with subjective assessments made by radiologists on medical images [56].”
MethodDiffusion Models Beat GANs on Image Synthesis
Dhariwal, P., & Nichol, A. (2021) · arXiv · doi:10.48550/arxiv.2105.05233 · Cited by 3,362
Deep Unsupervised Learning using Nonequilibrium Thermodynamics
Sohl-Dickstein, J., Weiss, E. A., Maheswaranathan, N., & Ganguli, S. (2015) · arXiv · doi:10.48550/arxiv.1503.03585 · Cited by 2,637
Denoising Diffusion Implicit Models
Song, J., Meng, C., & Ermon, S. (2020) · arXiv · doi:10.48550/arxiv.2010.02502 · Cited by 2,507 · cited 1×
“Recently, diffusion models have received much attention due to their impressive image generation performance [22], [23], [24], [25], [26], [27], enjoying the advantages of multiple generative models: good distribution coverage similar to variational autoencoder and better generation quality than…”
BackgroundFilm: Visual reasoning with a general conditioning layer
Perez, E., Strub, F., De Vries, H., Dumoulin, V., & Courville, A. (2018) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v32i1.11671 · Cited by 2,490
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464 · cited 1×
“However, X-ray ionizing radiation in CT scans could cause health risks such as hair loss and cancer [1], [2].”
BackgroundScore-Based Generative Modeling through Stochastic Differential Equations
Song, Y., Sohl-Dickstein, J., Kingma, D. P., Kumar, A., Ermon, S., & Poole, B. (2020) · arXiv · doi:10.48550/arxiv.2011.13456 · Cited by 1,953 · cited 3×
“The sampling process of Gaussian diffusion models can be unified into a stochastic differential equation (SDE) to guarantee good target distribution coverage [28].”
BackgroundMethodLow-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866 · cited 2×
“Initially, some researchers optimized encoder-decoder networks by minimizing the pixel-wise loss between the denoised and normal-dose CT (NDCT) images; one representative model is the residual encoder-decoder convolutional neural network (RED-CNN) [14].”
BackgroundSelf-citationDiffusion Models: A Comprehensive Survey of Methods and Applications
Yang, L., Zhang, Z., Song, Y., Hong, S., Xu, R., Zhao, Y., Zhang, W., Cui, B., & Yang, M.-H. (2024) · ACM Computing Surveys · doi:10.1145/3626235 · Cited by 1,704 · cited 1×
“…models have received much attention due to their impressive image generation performance [22], [23], [24], [25], [26], [27], enjoying the advantages of multiple generative models: good distribution coverage similar to variational autoencoder and better generation quality than GANs [28], [29], [30].”
BackgroundYang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630 · cited 3×
“For example, Yang et al. combined Wasserstein GAN and perceptual loss (WGAN-VGG) to produce more realistic denoised images [19].”
BackgroundMethodInfluentialSelf-citationImproved Denoising Diffusion Probabilistic Models
Nichol, A., & Dhariwal, P. (2021) · arXiv · doi:10.48550/arxiv.2102.09672 · Cited by 1,550 · cited 4×
“Recently, diffusion models have received much attention due to their impressive image generation performance [22], [23], [24], [25], [26], [27], enjoying the advantages of multiple generative models: good distribution coverage similar to variational autoencoder and better generation quality than…”
BackgroundMethodInfluentialToward Convolutional Blind Denoising of Real Photographs
Guo, S., Yan, Z., Zhang, K., Zuo, W., & Zhang, L. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00181 · Cited by 1,221 · cited 1×
“Following [49], we used a U-Net as the backbone of the proposed CLEAR-Net, which consists of two downsampling blocks, one middle block, two upsampling blocks, and an output convolutional layer.”
MethodSodickson, A., Baeyens, P. F., Andriole, K. P., Prevedello, L. M., Nawfel, R. D., Hanson, R., & Khorasani, R. (2009) · Radiology · doi:10.1148/radiol.2511081296 · Cited by 990 · cited 1×
“However, X-ray ionizing radiation in CT scans could cause health risks such as hair loss and cancer [1], [2].”
BackgroundImage quality assessment based on a degradation model
Damera-Venkata, N., Kite, T. D., Geisler, W. S., Evans, B. L., & Bovik, A. C. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.841940 · Cited by 806 · cited 1×
“In addition, we also used three new objective IQA metrics, i . e . feature similarity index (FSIM) [53], visual information fidelity (VIF) [54], and noise quality metric (NQM) [55], which have demonstrated improved alignment with subjective assessments made by radiologists on medical images [56].”
MethodHigh-Resolution Image Synthesis with Latent Diffusion Models
Rombach, R., Blattmann, A., Lorenz, D., Esser, P., & Ommer, B. (2021) · arXiv · doi:10.48550/arxiv.2112.10752 · Cited by 737
Wang, J., Li, T., Lu, H., & Liang, Z. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.882141 · Cited by 533 · cited 2×
“However, sinogram preprocessing may cause blurred edges and resolution loss while iterative reconstruction methods suffer from expensive computational cost [3], [4], [5].”
MethodDeep learning for tomographic image reconstruction
Wang, G., Ye, J. C., & De Man, B. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-00273-z · Cited by 531 · cited 1×
“In recent years, many efforts have been made to develop deep learning (DL) techniques for LDCT image post-processing, achieving promising performance [12], [13].”
BackgroundShan, H., Padole, A., Homayounieh, F., Kruger, U., Khera, R. D., Nitiwarangkul, C., Kalra, M. K., & Wang, G. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0057-9 · Cited by 417 · cited 1×
“In recent years, many efforts have been made to develop deep learning (DL) techniques for LDCT image post-processing, achieving promising performance [12], [13].”
BackgroundSelf-citationShan, H., Zhang, Y., Yang, Q., Kruger, U., Kalra, M. K., Sun, L., Cong, W., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2832217 · Cited by 411 · cited 2×
“However, sinogram preprocessing may cause blurred edges and resolution loss while iterative reconstruction methods suffer from expensive computational cost [3]–[5].”
MethodSelf-citationSharpness-Aware Low-Dose CT Denoising Using Conditional Generative Adversarial Network
Yi, X., & Babyn, P. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0056-0 · Cited by 343 · cited 1×
“3) Piglet Dataset: To further examine the generalization performance of different methods on a different center dataset, we also used a real piglet dataset acquired using a GE Discovery CT750 HD scanner, which contains a total of 850 CT images [47].”
MethodLi, Z., Yu, L., Trzasko, J. D., Lake, D. S., Blezek, D. J., Fletcher, J. G., McCollough, C. H., & Manduca, A. (2013) · Medical Physics · doi:10.1118/1.4851635 · Cited by 299 · cited 1×
“Li et al. utilized the analytical noise map obtained from repeated scans of the phantom data to improve the NLM algorithm, enabling adaptive denoising based on the local noise level of the CT image [10].”
MethodSelf-citationLow‐dose CT image and projection dataset
Moen, T. R., Chen, B., Holmes, D. R., Duan, X., Yu, Z., Yu, L., Leng, S., Fletcher, J. G., & McCollough, C. H. (2021) · Medical Physics · doi:10.1002/mp.14594 · Cited by 287 · cited 1×
“2) Mayo 2020 Dataset: To examine the generalization performance of different methods to new dose levels on the same center dataset, “Low Dose CT Image and Projection Data” latest released by Mayo Clinic in 2020 was used as external testing, which is named Mayo 2020 dataset [46].”
MethodGutjahr, R., Halaweish, A. F., Yu, Z., Leng, S., Yu, L., Li, Z., Jorgensen, S. M., Ritman, E. L., Kappler, S., & McCollough, C. H. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000251 · Cited by 282 · cited 1×
“In addition, we incorporated the contrast-to-noise ratio (CNR) [57], [58] to assess the detectability of low-contrast lesions in Figs.”
MethodSelf-citationSolving 3D Inverse Problems Using Pre-Trained 2D Diffusion Models
Chung, H., Ryu, D., McCann, M. T., Klasky, M., & Ye, J. C. (2023) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr52729.2023.02159 · Cited by 280 · cited 1×
“Recently, diffusion models have received much attention due to their impressive image generation performance [22], [23], [24], [25], [26], [27], enjoying the advantages of multiple generative models: good distribution coverage similar to variational autoencoder and better generation quality than…”
BackgroundArtifacts at Cardiac CT: Physics and Solutions
Kalisz, K. R., Buethe, J. Y., Saboo, S. S., Abbara, S., Halliburton, S. S., & Rajiah, P. S. (2016) · Radiographics · doi:10.1148/rg.2016160079 · Cited by 269 · cited 1×
“The causes of noise in LDCT images are notably intricate and can be influenced by a multitude of factors, including scattering, beam hardening, patient motion, metal implants, etc [62].”
BackgroundMa, J., Huang, J., Feng, Q., Zhang, H., Lu, H., Liang, Z., & Chen, W. (2011) · Medical Physics · doi:10.1118/1.3638125 · Cited by 249 · cited 1×
“For example, Ma et al. leveraged the redundancy of information in the previous normal-dose scan to compute non-local weights for non-local mean (NLM)-based LDCT image denoising [9].”
BackgroundCycle‐consistent adversarial denoising network for multiphase coronary CT angiography
Kang, E., Koo, H. J., Yang, D. H., Seo, J. B., & Ye, J. C. (2019) · Medical Physics · doi:10.1002/mp.13284 · Cited by 229 · cited 1×
“To alleviate this problem, some works use generative adversarial networks (GANs) to preserve more textures and details as close to NDCT images as possible [18].”
BackgroundImproving abdomen tumor low-dose CT images using a fast dictionary learning based processing
Chen, Y., Yin, X., Shi, L., Shu, H., Luo, L., Coatrieux, J.-L., & Toumoulin, C. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5803 · Cited by 223 · cited 1×
“Unlike them, image post-processing algorithms [6], [7], [8] directly process the reconstructed images and are gaining popularity due to their plug-and-play nature without access to raw data.”
BackgroundHuang, Z., Zhang, J., Zhang, Y., & Shan, H. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3128703 · Cited by 215 · cited 2×
“Huang et al. proposed a dual-domain GAN (DU-GAN) to learn the global and local differences between the denoised and NDCT images [20].”
BackgroundSelf-citationMason, A., Rioux, J., Clarke, S. E., Costa, A., Schmidt, M., Keough, V., Huynh, T., & Beyea, S. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2930338 · Cited by 204 · cited 1×
“In addition, we also used three new objective IQA metrics, i . e . feature similarity index (FSIM) [53], visual information fidelity (VIF) [54], and noise quality metric (NQM) [55], which have demonstrated improved alignment with subjective assessments made by radiologists on medical images [56].”
MethodContent-Noise Complementary Learning for Medical Image Denoising
Geng, M., Meng, X., Yu, J., Zhu, L., Jin, L., Jiang, Z., Qiu, B., Li, H., Kong, H., Yuan, J., et al. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3113365 · Cited by 183 · cited 1×
“…methods: RED-CNN [14] and PDF-RED-CNN [15]; 3) GAN-based methods: WGAN-VGG [19], DU-GAN [20], and Content-Noise Complementary Learning with U-Net (CNCL-U-Net) [51]; and 4) Diffusion-based meth-ods: Denoising Diffusion Models for Denoising Diffusion MRI (DDM 2 ), and Improved DDPM (IDDPM) [25].”
MethodSelf-citationA Simple Low-Dose X-Ray CT Simulation From High-Dose Scan
Zeng, D., Huang, J., Bian, Z., Niu, S., Zhang, H., Feng, Q., Liang, Z., & Ma, J. (2015) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2015.2467219 · Cited by 179
Block matching 3D random noise filtering for absorption optical projection tomography
Fumene Feruglio, P., Vinegoni, C., Gros, J., Sbarbati, A., & Weissleder, R. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/18/009 · Cited by 175 · cited 1×
“Unlike them, image post-processing algorithms [6], [7], [8] directly process the reconstructed images and are gaining popularity due to their plug-and-play nature without access to raw data.”
BackgroundNoise Suppression With Similarity-Based Self-Supervised Deep Learning
Niu, C., Li, M., Fan, F., Wu, W., Guo, X., Lyu, Q., & Wang, G. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3231428 · Cited by 170 · cited 1×
“For the DDM 2 training, we replaced the slice-wise pre-trained MRI denoising model with Noise2Sim [52], which is a well-designed LDCT denoising model.”
MethodSong, Y., Dhariwal, P., Chen, M., & Sutskever, I. (2023) · arXiv · doi:10.48550/arxiv.2303.01469 · Cited by 155
Kim, B., Han, M., Shim, H., & Baek, J. (2019) · Medical Physics · doi:10.1002/mp.13713 · Cited by 117
Seeing Mt. Rainier: Lucky imaging for multi-image denoising, sharpening, and haze removal
Joshi, N., & Cohen, M. F. (2010) · IEEE International Conference on Computational Photography (ICCP) · doi:10.1109/iccphot.2010.5585096 · Cited by 106 · cited 1×
“Moreover, for noise with zero means, it is commonly assumed that a clean image represents the expectation of multiple sets of noise measurements [35]–[37].”
BackgroundXia, W., Lu, Z., Huang, Y., Liu, Y., Chen, H., Zhou, J., & Zhang, Y. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3085839 · Cited by 93 · cited 5×
“How to rapidly adapt one trained model to new unseen dose levels using as few as resources is an important clinical question [15], [41], [42].”
BackgroundMethodInfluentialSelf-citationRobust Low-Dose CT Sinogram Preprocessing via Exploiting Noise-Generating Mechanism
Xie, Q., Zeng, D., Zhao, Q., Meng, D., Xu, Z., Liang, Z., & Ma, J. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2767290 · Cited by 79 · cited 2×
“We set the hyperparameters of the compared DL-based methods following the original paper or official open-source codes, while all hyperparameters of PWLS adhered to the settings provided in the open-source code of [3].”
MethodDenoised and texture enhanced MVCT to improve soft tissue conspicuity
Sheng, K., Gou, S., Wu, J., & Qi, X. S. (2014) · Medical Physics · doi:10.1118/1.4894714 · Cited by 77 · cited 1×
“Sheng et al. proposed a block matching 3D (BM3D)-based algorithm for low-dose megavoltage CT image denoising, which uses a saliency map, derived from the residual texture information after BM3D denoising, to enhance the visual conspicuity of soft tissue [11].”
MethodLearning from scanners: Bias reduction and feature correction in radiomics
Zhovannik, I., Bussink, J., Traverso, A., Shi, Z., Kalendralis, P., Wee, L., Dekker, A., Fijten, R., & Monshouwer, R. (2019) · Clinical and Translational Radiation Oncology · doi:10.1016/j.ctro.2019.07.003 · Cited by 75 · cited 1×
“This dataset contains 9 different dose scans (from 33 to 499mAs) using the Thorax protocol [48].”
MethodConsensus Neural Network for Medical Imaging Denoising with Only Noisy Training Samples
Wu, D., Gong, K., Kim, K., Li, X., & Li, Q. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32251-9_81 · Cited by 72
A convolutional neural network for ultra‐low‐dose CT denoising and emphysema screening
Zhao, T., McNitt‐Gray, M. F., & Ruan, D. (2019) · Medical Physics · doi:10.1002/mp.13666 · Cited by 60 · cited 1×
“In this experiment, we simulated 50%, 25%, 10% and 5% dose data, of which 5% corresponds to ultra-low-dose situation [45].”
MethodCoCoDiff: a contextual conditional diffusion model for low-dose CT image denoising
Gao, Q., & Shan, H. (2022) · Developments in X-Ray Tomography · doi:10.1117/12.2634939 · Cited by 60 · cited 5×
“1) Generalized Diffusion Model for Low-Dose CT: Previous diffusion-based LDCT denoising methods [31], [32] typically characterize the diffusion process as the addition of Gaussian noise and use LDCT images as a condition to predict the corresponding NDCT image.”
BackgroundMethodInfluentialSelf-citationCold Diffusion for Speech Enhancement
Yen, H., Germain, F. G., Wichern, G., & Roux, J. L. (2023) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp49357.2023.10096064 · Cited by 57 · cited 2×
“Recently, a generalized diffusion model, referred to as cold diffusion, extends classical diffusion models by gradually degrading images through a pre-defined degradation operator, such as adding various types of noise, blurring, downsampling, etc [33], [34].”
BackgroundYu, L., Chen, B., Kofler, J. M., Favazza, C. P., Leng, S., Kupinski, M. A., & McCollough, C. H. (2017) · Medical Physics · doi:10.1002/mp.12380 · Cited by 49 · cited 1×
“The utility of CHO has been explored in assessing the low-contrast detection task performance of different CT image reconstruction algorithms, demonstrating a high correlation with human observers [59], [60], [61].”
BackgroundSompel, D. V. D., Brady, S. M., & Boone, J. M. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.07.004 · Cited by 46 · cited 1×
“The utility of CHO has been explored in assessing the low-contrast detection task performance of different CT image reconstruction algorithms, demonstrating a high correlation with human observers [59], [60], [61].”
BackgroundNoise Characteristics Modeled Unsupervised Network for Robust CT Image Reconstruction
Li, D., Bian, Z., Li, S., He, J., Zeng, D., & Ma, J. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3197400 · Cited by 35 · cited 2×
“How to rapidly adapt one trained model to new unseen dose levels using as few as resources is an important clinical question [15], [41], [42].”
BackgroundReview of CT image reconstruction open source toolkits
Shi, L., Liu, B., Yu, H., Wei, C., Wei, L., Zeng, L., & Wang, G. (2020) · Journal of X-Ray Science and Technology · doi:10.3233/xst-200666 · Cited by 29 · cited 1×
“We conducted data simulations based on the MIRT tool-box [50].”
MethodA Bias-Reducing Loss Function for CT Image Denoising
Nagare, M., Melnyk, R., Rahman, O., Sauer, K. D., & Bouman, C. A. (2021) · ICASSP 2021 - 2021 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp39728.2021.9413855 · Cited by 20 · cited 1×
“Despite the outstanding denoising performance, these methods often lead to over-smoothing images [16], [17].”
BackgroundPark, P. C., Choi, G. W., Zaid, M., Elganainy, D., Smani, D. A., Tomich, J., Samaniego, R., Ma, J., Tamm, E. P., Beddar, S. A., et al. (2019) · Medical Physics · doi:10.1002/mp.13769 · Cited by 16
Cited by
Diffusion models in medical imaging: A comprehensive survey
Kazerouni, A., Aghdam, E. K., Heidari, M., Azad, R., Fayyaz, M., Hacihaliloglu, I., & Merhof, D. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102846 · Cited by 765
Wang, S., Zhou, X., Li, C., Wang, S., Li, Y., Tan, T., & Zheng, H. (2025) · Research · doi:10.34133/research.1029 · Cited by 29
Metadata
- Authors
- Gao, Q., Li, Z., Zhang, J., Zhang, Y., & Shan, H.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2024-02
- Volume
- 43
- Issue
- 2
- Pages
- 745-759
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W4387164668
- Cited by
- 162
- References
- 56
- FWCI
- 14.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.