CoChat

Inclination measurement of human movement using a 3-D accelerometer with autocalibration

Open access
Luinge, H.J., Veltink, P.H. · 2004 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 307

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

In the medical field, accelerometers are often used for measuring inclination of body segments and activity of daily living (ADL) because they are small and require little power. A drawback of using accelerometers is the poor quality of inclination estimate for movements with large accelerations. This paper describes the design and performance of a Kalman filter to estimate inclination from the signals of a triaxial accelerometer. This design is based on assumptions concerning the frequency content of the acceleration of the movement that is measured, the knowledge that the magnitude of the gravity is 1 g and taking into account a fluctuating sensor offset. It is shown that for measuring trunk and pelvis inclination during the functional three-dimensional activity of stacking crates, the inclination error that is made is approximately 20 root-mean square. This is nearly twice as accurate as compared to current methods based on low-pass filtering of accelerometer signals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2003.822759

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 307

Metadata

Authors
Luinge, H. J., & Veltink, P. H.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2004-03
Volume
12
Issue
1
Pages
112-121
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2162547416
Cited by
307
References
21
FWCI
31.24
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.