Inclination measurement of human movement using a 3-D accelerometer with autocalibration
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
In the medical field, accelerometers are often used for measuring inclination of body segments and activity of daily living (ADL) because they are small and require little power. A drawback of using accelerometers is the poor quality of inclination estimate for movements with large accelerations. This paper describes the design and performance of a Kalman filter to estimate inclination from the signals of a triaxial accelerometer. This design is based on assumptions concerning the frequency content of the acceleration of the movement that is measured, the knowledge that the magnitude of the gravity is 1 g and taking into account a fluctuating sensor offset. It is shown that for measuring trunk and pelvis inclination during the functional three-dimensional activity of stacking crates, the inclination error that is made is approximately 20 root-mean square. This is nearly twice as accurate as compared to current methods based on low-pass filtering of accelerometer signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
System identification—Theory for the user
Sinha, N. K. (1989) · Automatica · doi:10.1016/0005-1098(89)90019-8 · Cited by 9,184
introduction to random signals and applied kalman filtering
Brown, R. G., & Hwang, P. Y. (1992) · Virtual Defense Library (Ministerio de Defensa) · Cited by 3,365
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Self-citationDetection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491
Self-citationDetection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480
Moe-Nilssen, R. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00089-8 · Cited by 404
Uswatte, G., Miltner, W. H. R., Foo, B., Varma, M., Moran, S., & Taub, E. (2000) · Stroke · doi:10.1161/01.str.31.3.662 · Cited by 232
Procedure for in-use calibration of triaxial accelerometers in medical applications
Lötters, J. C., Schipper, J., Veltink, P. H., Olthuis, W., & Bergveld, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)00049-1 · Cited by 203
Self-citationBachmann, E. R. (2000) · Calhoun: The Naval Postgraduate School Institutional Archive (Naval Postgraduate School) · Cited by 173
Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
Willemsen, A. T. M., Bloemhof, F., & Boom, H. B. K. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.64463 · Cited by 169
Procedure for effortless in-field calibration of three-axial rate gyro and accelerometers
Ferraris, F., Grimaldi, U., & Parvis, M. (1995) · PORTO@Iris · Cited by 163
Inertial sensing of human movement
Luinge, H. J. (2002) · University of Twente Research Information · Cited by 148
Self-citationBody position can be monitored in 3D using miniature accelerometers and earth-magnetic field sensors
Kemp, B., Janssen, A. J. M. W., & van der Kamp, B. (1998) · Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control · doi:10.1016/s0924-980x(98)00053-8 · Cited by 124
A method for inverse dynamic analysis using accelerometry
van den Bogert, A. J., Read, L., & Nigg, B. M. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00155-7 · Cited by 99
New controller for functional electrical stimulation systems
Fisekovic, N., & Popović, D. B. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00069-8 · Cited by 40
Virtual artificial sensor technique for functional electrical stimulation
Tong, R. K., & Granat, M. H. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00038-1 · Cited by 34
Technical Note: Method for objective assessment of physical work load at the workplace
Busser, H. J., KORTE, W. G. D., Glerum, E. B. C., & van Lummel, R. C. (1998) · Ergonomics · doi:10.1080/001401398186252 · Cited by 23
Inertial sensing in ambulatory back load estimation
Baten, C. T. M., Oosterhoff, P., Kingma, I., Veltink, P. H., & Hermens, H. J. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.651834 · Cited by 18
Self-citation
Cited by
Estimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887
(2009) · Cited by 701
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Self-citation
Metadata
- Authors
- Luinge, H. J., & Veltink, P. H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2004-03
- Volume
- 12
- Issue
- 1
- Pages
- 112-121
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2162547416
- Cited by
- 307
- References
- 21
- FWCI
- 31.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.