Inclination measurement of human movement using a 3-D accelerometer with autocalibration
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
In the medical field, accelerometers are often used for measuring inclination of body segments and activity of daily living (ADL) because they are small and require little power. A drawback of using accelerometers is the poor quality of inclination estimate for movements with large accelerations. This paper describes the design and performance of a Kalman filter to estimate inclination from the signals of a triaxial accelerometer. This design is based on assumptions concerning the frequency content of the acceleration of the movement that is measured, the knowledge that the magnitude of the gravity is 1 g and taking into account a fluctuating sensor offset. It is shown that for measuring trunk and pelvis inclination during the functional three-dimensional activity of stacking crates, the inclination error that is made is approximately 20 root-mean square. This is nearly twice as accurate as compared to current methods based on low-pass filtering of accelerometer signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
System identification—Theory for the user
Sinha, N. K. (1989) · Automatica · doi:10.1016/0005-1098(89)90019-8 · Cited by 9,184
introduction to random signals and applied kalman filtering
Brown, R. G., & Hwang, P. Y. (1992) · Virtual Defense Library (Ministerio de Defensa) · Cited by 3,365
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Self-citationDetection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491
Self-citationDetection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480
Moe-Nilssen, R. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00089-8 · Cited by 404
Uswatte, G., Miltner, W. H. R., Foo, B., Varma, M., Moran, S., & Taub, E. (2000) · Stroke · doi:10.1161/01.str.31.3.662 · Cited by 232
Cited by
Estimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887
(2009) · Cited by 701
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Self-citationAccelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588
Self-citationYun, X., & Bachmann, E. R. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.886270 · Cited by 569
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356
Self-citationEstimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s110201489 · Cited by 349
“Very interesting is the work in [14], where the authors used one tri-axial accelerometer to measure inclination during dynamic tasks without requiring additional sensors.”
BackgroundInertial sensor-based knee flexion/extension angle estimation
Cooper, G., Sheret, I., McMillian, L., Siliverdis, K., Sha, N., Hodgins, D., Kenney, L., & Howard, D. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.004 · Cited by 281
Calibration and data fusion solution for the miniature attitude and heading reference system
Jurman, D., Jankovec, M., Kamnik, R., & Topič, M. (2007) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.05.008 · Cited by 223
“Nowadays, a small-size inertial measurement unit (IMU) and electronic compass with of-the-shelf sensors are found in variety of applications, such as unmanned aerial [1] and underwater vehicles [2], handheld navigation devices, human motion tracking [ 3 ] and many more.”
BackgroundDejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s111009182 · Cited by 168
“The KF for body segment orientation in [16] is thus extended with models of gyro and magnetic sensor biases, in the attempt to prevent heading drift and to compensate magnetic disturbances.”
BackgroundA Triaxial Accelerometer Calibration Method Using a Mathematical Model
Won, S. P., & Golnaraghi, F. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2031849 · Cited by 163
“T RIAXIAL accelerometers are used in various applications, such as inertial navigation systems (INSs) [1], [2] and inclinometers [3]–[5].”
MethodAccuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion
Godwin, A., Agnew, M., & Stevenson, J. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000109 · Cited by 107
Joint Angle Measurement Using Strategically Placed Accelerometers and Gyroscope
Vikas, V., & Crane, C. D. (2016) · Journal of Mechanisms and Robotics · doi:10.1115/1.4031299 · Cited by 15
Optimal Wiener Filter for a Body Mounted Inertial Attitude Sensor
Rizun, P. (2008) · Journal of Navigation · doi:10.1017/s0373463308004736 · Cited by 6
Metadata
- Authors
- Luinge, H. J., & Veltink, P. H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2004-03
- Volume
- 12
- Issue
- 1
- Pages
- 112-121
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2162547416
- Cited by
- 307
- References
- 21
- FWCI
- 31.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.