The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.
Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex
Abstract
Multiple-electrode arrays are valuable both as a research tool and as a sensor for neuromotor prosthetic devices, which could potentially restore voluntary motion and functional independence to paralyzed humans. Long-term array reliability is an important requirement for these applications. Here, we demonstrate the reliability of a regular array of 100 microelectrodes to obtain neural recordings from primary motor cortex (MI) of monkeys for at least three months and up to 1.5 years. We implanted Bionic (Cyberkinetics, Inc., Foxboro, MA) silicon probe arrays in MI of three Macaque monkeys. Neural signals were recorded during performance of an eight-direction, push-button task. Recording reliability was evaluated for 18, 35, or 51 sessions distributed over 83, 179, and 569 days after implantation, respectively, using qualitative and quantitative measures. A four-point signal quality scale was defined based on the waveform amplitude relative to noise. A single observer applied this scale to score signal quality for each electrode. A mean of 120 (+/- 17.6 SD), 146 (+/- 7.3), and 119 (+/- 16.9) neural-like waveforms were observed from 65-85 electrodes across subjects for all recording sessions of which over 80% were of high quality. Quantitative measures demonstrated that waveforms had signal-to-noise ratio (SNR) up to 20 with maximum peak-to-peak amplitude of over 1200 microv with a mean SNR of 4.8 for signals ranked as high quality. Mean signal quality did not change over the duration of the evaluation period (slope 0.001, 0.0068 and 0.03; NS). By contrast, neural waveform shape varied between, but not within days in all animals, suggesting a shifting population of recorded neurons over time. Arm-movement related modulation was common and 66% of all recorded neurons were tuned to reach direction. The ability for the array to record neural signals from parietal cortex was also established. These results demonstrate that neural recordings that can provide movement related signals for neural prostheses, as well as for fundamental research applications, can be reliably obtained for long time periods using a monolithic microelectrode array in primate MI and potentially from other cortical areas as well.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In fact, after appropriate control in experimental models to test their biocompatibility and efficacy [18], LIFEs have been recently used to control artificial devices [6,7,22-25] showing good results during short-term trials with human amputees.”
From Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces (2011) · cites this paper as [22]
In the citing paper
“These trials showed that subjects are able to control a one-degree of freedom hand prosthesis through online processing of the efferent neural signals, and that repeatable sensory feedback may be received by stimulating afferent fibers [22,23] corresponding to the missing hand/fingers territories.”
From Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces (2011) · cites this paper as [22]
Citations
Cites
Visual Feature Integration and the Temporal Correlation Hypothesis
Singer, W., & Gray, C. M. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.003011 · Cited by 3,217
Georgopoulos, A. P., Kalaska, J. F., Caminiti, R., & Massey, J. (1982) · Journal of Neuroscience · doi:10.1523/jneurosci.02-11-01527.1982 · Cited by 2,133
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,542
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,415
Self-citationBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 811
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 603
Fabrication and biocompatibility of polypyrrole implants suitable for neural prosthetics.
George, P. M., Lyckman, A., Laván, D., Hegde, A., Leung, Y., Avasare, R., Testa, C., Alexander, P. M., Langer, R., & Sur, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.037 · Cited by 560
Research works printed but not linked: 1
- Horch, 2002, World Scientific
Cited by
Sorted by citations
Items 301–400 of 414
An engineered home environment for untethered data telemetry from nonhuman primates
Powell, M. P., Britz, W. R., Harper, J. S., & Borton, D. A. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.06.013 · Cited by 7
“Standard surgical procedures were used which are described elsewhere [28].”
MethodAn Efficient Hardware Circuit for Spike Sorting Based on Competitive Learning Networks
Chen, H., Chen, C.-C., & Hwang, W. (2017) · Sensors · doi:10.3390/s17102232 · Cited by 7
“The MEAs have been extensively deployed to facilitate the development of applications such as brain-machine interface (BMI) and/or neuromotor prosthetic devices [3,4] for the rehabilitation of stroke or paralyzed patients.”
Falcone, J., Sohal, H. S., Kyriakides, T. R., & Bellamkonda, R. V. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab1ef9 · Cited by 7
When are correlations strong?Preprint
Azhar, F., & Bialek, W. (2010) · arXiv (Cornell University) · doi:10.48550/arxiv.1012.5987 · Cited by 7
“Given such data, what can we say about the global structure of the network?”
BackgroundMulti‐Channel Neural Interface for Neural Recording and Neuromodulation
Kim, E.-M., Chung, W. G., Kim, E., Oh, M., Paek, J., Lee, T., Kim, D., An, S. H., Kim, S., & Park, J. (2025) · Small Methods · doi:10.1002/smtd.202501227 · Cited by 9
Trends and Treatment Approaches for Complications in Neuroscience Experiments with Monkey Species
Jain, A. K., Tansey, G., Hartig, R., Mitchell, A. S., & Basso, M. A. (2023) · Comparative Medicine · doi:10.30802/aalas-cm-22-000079 · Cited by 6
Predicting Single-Neuron Activity in Locally Connected Networks
Azhar, F., & Anderson, W. S. (2012) · Neural Computation · doi:10.1162/neco_a_00343 · Cited by 6
“The reader is referre d to Truccolo, Eden, Fellows, Donoghue, & Brown (2005), Truccolo et al. (2010), Brow n, Barbieri, Eden, & Frank (2004), Truccolo (2010), and Daley & Vere-Jones (2003 ) for further details.”
BackgroundInfluentialA mobile embedded platform for high performance neural signal computation and communication
Heelan, C., Komar, J., Vargas-Irwin, C. E., Simeral, J. D., & Nurmikko, A. V. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348356 · Cited by 6
“For details on array structure and surgical procedures, see [10, 11].”
BackgroundSelf-citationSmart Dura: a functional artificial dura for multi-modal neural recording and modulation
Vargo, S. M., Hong, N., Belloir, T., Stanis, N., Zhou, J., Khateeb, K., Hatanaka, G., Ahmed, Z., Kimukin, Ï., Griggs, D. J., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01166-8 · Cited by 6
“As detailed in the Methods section, to determine the CIC we repeated the injection of charge-balanced current pulses with a frequency and pulse width tailored for our NHP experiments 36 with increasing current amplitudes until the measured voltage levels exceeded safe limits (i.e., the water window).”
InfluentialOpie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., May, C. N., Grayden, D. B., & Oxley, T. J. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512385 · Cited by 5
Effects of micromachining on anti-oxidant elution from a mechanically-adaptive polymer
Mueller, N. N., Kim, Y., Ocoko, M. Y. M., Dernelle, P., Kale, I. P., Patwa, S., Hermoso, A. C., Chirra, D., Capadona, J. R., & Hess‐Dunning, A. (2024) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ad27f7 · Cited by 5
“Each channel is deemed acceptable for neural recording if its magnitude at 1 kHz is between 100– 1000 k Ω [10, 20, 56–58].”
BackgroundProspects for a Robust Cortical Recording Interface
Shoffstall, A. J., & Capadona, J. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00028-0 · Cited by 5
Zhang, X., Chen, C., Ni, G., Hai, Y., Chen, B., Zhou, Y. C., Zhang, B., Gui, C., & Cheng, M. M. (2019) · Medical Devices & Sensors · doi:10.1002/mds3.10026 · Cited by 5
Kim, T., Zhong, Y., & Giszter, S. F. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2911912 · Cited by 5
“This severely limits chronic clinical use [8]–[11], and electrodes pose significant risk.”
Visual epidural field potentials possess high functional specificity in single trials
Fischer, B., Schander, A., Kreiter, A. K., Lang, W., & Wegener, D. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00510.2019 · Cited by 5
Design and Microfabrication Considerations for Reliable Flexible Intracortical Implants
Sohal, H. S., Vassilevski, K., Jackson, A., Baker, S. N., & O’Neill, A. (2016) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2016.00005 · Cited by 4
“As a demonstration of this, we show that we can acutely record from the mouse cortex with good SNR (Figure 9) following Suner’s method (Suner et al., 2005; Ward et al., 2009).”
MethodYang, S., Huang, C.-J., & Huang, J.-S. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108208 · Cited by 4
Using branch predictors to predict brain activity in brain-machine implants
Bhattacharjee, A. (2017) · IEEE/ACM International Symposium on Microarchitecture (MICRO) · doi:10.1145/3123939.3123943 · Cited by 4
Badi, M., Borgognon, S., O’Doherty, J. E., & Shokur, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00008-3 · Cited by 4
Prospective and retrospective representations of saccadic movements in primate prefrontal cortex
Calangiu, I., Kollmorgen, S., Reppas, J. B., & Mante, V. (2025) · Cell Reports · doi:10.1016/j.celrep.2025.115289 · Cited by 4
Searching for semantics in the retinal code
Bonomini, M. P., Vicente, J. M. F., & Fernández, E. (2008) · Neurocomputing · doi:10.1016/j.neucom.2008.10.009 · Cited by 4
Nickl, R. W., Anaya, M. A., Thomas, T. M., Fifer, M. S., Candrea, D. N., McMullen, D. P., Thompson, M. C., Osborn, L. E., Anderson, W. S., Wester, B. A., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-13436-2 · Cited by 4
Intracranialbrain–computer interfaces for communication and control
Jarosiewicz, B., & Hochberg, L. R. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995583.042 · Cited by 4
System and Circuit Design for Biologically-Inspired Intelligent Learning
Temel, T. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-018-1 · Cited by 4
Designing a Neural Interface System to Restore Mobility
Donoghue, J. P., & Hochberg, L. R. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374248-3.00020-3 · Cited by 4
Self-citationYin, M., Wang, X., Zhang, L.-C., Shu, G., Wang, Z., Huang, S., & Yin, M. (2024) · Biosensors · doi:10.3390/bios14070323 · Cited by 4
“However, for high impedance electrodes [23,24] (2–3 M Ω ) or for applications requiring large stimulation currents such as DBS or SCS (>1 mA), high compliance voltages are indispensable.”
BackgroundApplications of Endovascular Brain–Computer Interface in Patients with Alzheimer’s Disease
Sun, Y., Chen, D., Ye, Q., You, Z., Zhao, Z., Shi, J., Sun, H., Li, S., Xu, Y., Xu, Y., et al. (2025) · Research · doi:10.34133/research.1049 · Cited by 3
“However, even in these systems, there is always some relative movement ( 50 μ m) between the electrodes and neurons [ 7 ], and fluctuations in electrical activity both inside and outside neurons can lead to unstable spike amplitudes.”
Won, S., Binder, S., Boyadzhiev, A. M., Zhou, Q., Vafaei, A., Botero, J., Lim, T., Angelucci, A., Blair, S., Fan, Y., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c07028 · Cited by 3
Chan, K. S., Guo, Y., Duan, Q., Wang, X., Hao, Y., Wu, S., & Dai, X. (2026) · ACS Nano · doi:10.1021/acsnano.6c05215 · Cited by 3
Hulambukie, E., Liu, M., Wu, W., Xiang, X., Hanning, S. M., & Wen, J. (2025) · Acta Materia Medica · doi:10.15212/amm-2025-0019 · Cited by 3
Thin-Film Microelectrode Arrays for Biomedical Applications
Cheung, K. C. (2010) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_6 · Cited by 3
“This array was used to record chronically from the monkey parietal cortex, with some electrodes still viable after 18 months [ 34 ].”
MethodVaskov, A. K., & Chestek, C. A. (2021) · Hand Clinics · doi:10.1016/j.hcl.2021.04.003 · Cited by 3
Failure Reason of PI Test Samples of Neural Implants
Guljakow, J., & Lang, W. (2023) · Sensors · doi:10.3390/s23031340 · Cited by 3
“The first results of in-vivo experiments are described in [44].”
BackgroundNeuron-Type-Specific Utility in a Brain-Machine Interface: a Pilot Study
Garcia-Garcia, M. G., Bergquist, A. J., Vargas-Pérez, H., Nagai, M. K., Zariffa, J., Márquez-Chin, C., & Popović, M. R. (2017) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2017.1369214 · Cited by 3
The Future of Neural Interface Technology
Park, M. C., Goldman, M. A., Belknap, T. W., & Friehs, G. M. (2009) · Springer eBooks · doi:10.1007/978-3-540-69960-6_193 · Cited by 3
Artificial Neural Networks and Retinal Ganglion Cell Responses
María, P., Jose, M., & Fernández, E. (2011) · InTech eBooks · doi:10.5772/15954 · Cited by 3
“The issue of classification has long been a central topic in the analysis of multielectrode data, either for spike sorting or for getting insight into interactions among ensembles of neurons (Fernandez et al., 2000; Nicolelis, 2003; Shoham et al., 2003; Carmena et al., 2005; Fernandez et al., 2005; Nicolelis, 2005; Su…”
BackgroundComputer cursor control by motor cortical signals in humans with tetraplegia
Kim, S.-P., Simeral, J. D., Hochberg, L. R., Donoghue, J. P., & Black, M. J. (2009) · Cited by 3
Self-citationVariance in population firing rate as a measure of slow time-scale correlation
Snyder, A. C., Morais, M. J., & Smith, M. A. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00176 · Cited by 5
“Following the offline sorting procedure, we computed the signal-to-noise ratio (SNR) of each candidate unit as the ratio of the average waveform amplitude to the SD of the waveform noise (Nordhausen et al., 1996; Suner et al., 2005; Kelly et al., 2007).”
MethodSauter-Starace, F., Torres-Martinez, N., Agache, V., Pudda, C., Dijon, J., Piallat, B., Divoux, J., Bourquin, N., Charmeux, J. F., Berger, F. R., et al. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910617 · Cited by 3
A simple device allowing silicon microelectrode insertion for chronic neural recording in primates
Sakamoto, K., Matsuzaka, Y., Suenaga, T., WATANABE, H. K., Kobayashi, R., Fukushima, T., Katayama, N., Tanaka, T., Koyanagi, M., & Mushiake, H. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109245 · Cited by 3
“[ 13 ]). In those studies, once the electrodes were implanted aseptically, they were completely surrounded by dental acrylic cement or similar sort of materials as soon as possible.”
BackgroundFrampton, J. P., Hynd, M. R., Vargun, A., Roysam, B., & Shain, W. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335352 · Cited by 3
“hronic integration of microfabricated neuroprosthetic devices is currently limited by the ability to form stable interfaces with the central nervous system [12, 19].”
BackgroundImplantable Neural Sensors for Brain Machine Interface
Jang, J., Lee, J.-H., Kang, M., & Song, Y. (2015) · KAIST research series · doi:10.1007/978-94-017-9981-2_3 · Cited by 3
Operant conditioning reveals task-specific responses of single neurons in a brain–machine interface
Garcia-Garcia, M. G., Márquez-Chin, C., & Popović, M. R. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abeeac · Cited by 3
“Only neurons with a SNR >2 [20], refractory period >1 ms [21] and firing rate >1 Hz were selected for subsequent experimentation.”
Nonlinear physically-based models for decoding motor-cortical population activity
Shakhnarovich, G., Kim, S.-P., & Black, M. J. (2007) · The MIT Press eBooks · doi:10.7551/mitpress/7503.003.0162 · Cited by 3
“The experimental setup we consider in this paper involves an electrode array, implanted in the arm/hand area of the MI cortex of a behaving monkey [17].”
MethodPeripheral Nerve Interface Applications, EMG/ENG
Abdelghani, M., Abbas, J. J., & Jung, R. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_199-1 · Cited by 3
Implanted intracortical electrodes as chronic neural interfaces to the central nervous systemPreprint
Henderson, P. (2015) · doi:10.7287/peerj.preprints.1255v1 · Cited by 3
“2 Signal Stability Studies [75] have shown that day to day fluctuations occur within the consistency of a signal waveform and patterns, as well as signal viability.”
BackgroundMirkiani, S., O’Sullivan, C. L., Arefadib, A., Tyreman, N., Sari, K., Wilson, D., Tawakol, O., Troyk, P. R., Fox, R., & Mushahwar, V. K. (2026) · Scientific Reports · doi:10.1038/s41598-026-42212-9 · Cited by 2
“Despite this, stable cortical recordings over years after implantation have been reported 51,97 .”
Full‐Stack Architectures for Intelligent Brain‐Computer Interfaces
Lee, H. K., Kim, H. B., Park, S. U., Joo, J., Min, J., Lee, G., Kang, J. Y., Jeong, H., Yoo, J., & Won, S. M. (2026) · Advanced Science · doi:10.1002/advs.75838 · Cited by 2
Venuto, D. D., Ledochowitsch, P., Maharabitz, M., & Rabaey, J. M. (2014) · International Symposium on Quality Electronic Design (ISQED) · doi:10.1109/isqed.2014.6783350 · Cited by 2
“can occur lead-wire fracture, degradation of the electrode insulation, loosening of the head implant) [10-13].”
BackgroundA Biomimetic Adaptive Algorithm and Micropower Circuit Architecture for Implantable Neural Decoders
Rapoport, B. I., & Sarpeshkar, R. (2011) · IGI Global eBooks · doi:10.4018/978-1-60960-018-1.ch010 · Cited by 2
Bi-directional Optrode for quantitative prediction of neural interface failure
McLaughlin, B. L., Kampasi, K., Perlin, G. E., LeBlanc, J., Achyuta, A. K. H., Kumar, P., Cook, G., Segura, C., Mittal, V., & Kipke, D. R. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696084 · Cited by 2
Yu, Y., & Lo, R.-C. (2009) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2009.5305298 · Cited by 2
“These four categories correspond well with observations of unit quality based on signal-to-noise ratio made in similar recording studies [16, 17].”
ResultHeterogeneous domain adaptation for intracortical signal classification using domain consensus
Dong, Y., Hu, D., Wang, S., & He, J. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104540 · Cited by 2
Microelectrode Technologies for Deep Brain Stimulation
Han, M., & McCreery, D. B. (2009) · Biological and medical physics series · doi:10.1007/978-0-387-77261-5_6 · Cited by 2
“There are various substrates upon which batch-processed multisite microelectrodes are patterned, including silicon [16, 21, 29, 33, 36, 62, 107, 108, 124, 132, 138, 154], silicon-on-insulator [23, 34, 50, 63], polymer [2, 73, 123, 126, 135, 136], ceramic [98, 110], and metal [97].”
BackgroundRapoport, B. I. (2007) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 2
Material damage to multielectrode arrays after electrolytic lesioning is insignificantPreprint
Tor, A., Clarke, S. E., Bray, I. E., & Nuyujukian, P. (2025) · eLife · doi:10.1101/2025.03.26.645429 · Cited by 3
“Previousstudies have shown temporally decreasing performance of collected signals from long-term implanted arrays, thought to be a consequence of the immune response, mechanical movement of the array relative to surrounding tissue, and physical degradation of the array [20–22].”
Brain-Computer Interfaces for Rehabilitation After Stroke
Ganguly, K. (2024) · Springer eBooks · doi:10.1007/978-3-031-49963-0_27 · Cited by 1
Zheng, X., Zeng, J., Chen, T., Lin, Y., Yu, L., Li, Y., Lin, Z., Wu, X., Chen, F., Kang, D., et al. (2014) · Neurological Sciences · doi:10.1007/s10072-014-1775-8 · Cited by 1
“Signal-to-noise ratio (SNR) was calculated for unit quantification as well [15].”
MethodHuman Single Unit Activity for Reach and Grasp Motor Prostheses
Fried, I. (2014) · The MIT Press eBooks · doi:10.7551/mitpress/9780262027205.003.0017 · Cited by 1
Mehr als normal - verstehen wir die Enhancement-Debatte?
Rosahl, S. K. (2009) · TATuP Zeitschrift für Technikfolgenabschätzung in Theorie und Praxis · doi:10.14512/tatup.18.2.13 · Cited by 1
Bidirectional optimization of firing rate in a mouse neuronal brain–machine interface
Zhao, Y., Lu, P., Wang, X., & Yin, M. (2025) · Biology Letters · doi:10.1098/rsbl.2025.0176 · Cited by 1
Brain responses to neural prostheses
Capadona, J. R., & Marasco, P. D. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995583.040 · Cited by 1
Yu, Y., & Lo, R.-C. (2013) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237213500282 · Cited by 1
Reduction, Telemetry, and Processing of Neural Data for a Fully Implantable Data Acquisition System
Rizk, M. (2008) · DukeSpace (Duke University) · Cited by 1
Cortical surface recurrent brain-computer interfaces
Zanos, S. P. (2013) · ResearchWorks at the University of Washington (University of Washington) · Cited by 1
Huang, R. K.-J. (2010) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/vmzb-0n20 · Cited by 1
A Novel Flexible Sinusoidal Probe for Chronic Extracellular Brain RecordingPreprint
Sohal, H. S., Vassilevski, K. V., Andrew, J. O., Baker, S. N., & O'Neill, A. G. (2015) · arXiv (Cornell University) · Cited by 1
Falcone, J., Liu, T., Goldman, L., Pogue, D. D., Straka, M., Rieth, L. W., Bouton, C. E., & Sohal, H. S. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/402925 · Cited by 1
“This trend has been confirmed in studies using intracortical electrodes from cortex recordings in the chronic setting (Barrese et al. 2013; Perge et al. 2013; Sohal et al. 2014; Suner et al. 2005; Kuo et al. 2013; Barrese et al. 2016).”
Strategies for Optimizing Information Extraction from Cortical Recordings.
Langhals, N. B. (2011) · Deep Blue (University of Michigan) · Cited by 1
He, B. J. (2015) · Encyclopedia of Computational Neuroscience · doi:10.1007/978-1-4614-6675-8_545 · Cited by 1
Stochastic Inference and Bayesian Nonparametric Models in Electrophysiological Time Series
Carlson, D. (2015) · DukeSpace (Duke University)
Large-Scale Neuronal Network Changes Underlying Neuroprosthetic Learning
Koralek, A. C. (2014) · eScholarship (California Digital Library)
Translational research: application to human neural injury
Selzer, M. E., Clarke, S., Cohen, L. G., Kwakkel, G., & Miller, R. H. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995583.039
A novel 3D neural probe with integrated channel and its package
Fu, X., Xu, Y. P., Li, Y., Zhang, J., Luo, X., & Liu, S. (2014) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2014.6897284
“The Utah probe arrays are built in the direction of the probes [15-16].”
BackgroundA Direct Visual and Motor Neural Interface Demonstration in a Rat
Marzullo, T., Kim, E. D., Lehmkuhle, M. J., & Kipke, D. R. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369598
“In addition, electrode technology has increased substantially over the years, driven by the requirements of human neuroprosthetic devices [8-16].”
BackgroundSpatio-temporally controlled transfection of nucleic acid payloads in cell-culture
Jain, T., & Muthuswamy, J. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369666
Kreiman, G., Bansal, A. K., Singer, J. M., Anderson, W. S., Golby, A. J., & Joseph, R. M. (2012)
Truccolo, W., Vargas-Irwin, C. E., & Donoghue, J. P. (2012)
Self-citationDonoghue, J. P., Nurmikko, A. V., Black, M. J., & Hochberg, L. R. (2007)
Self-citationHokanson, J. (2014) · D-Scholarship@Pitt (University of Pittsburgh)
Power Conditioning and Stimulation for Wireless Neural Interface ICs
Biederman, W. (2014) · eScholarship (California Digital Library)
CHANGING THE BRAIN-MACHINE INTERFACE PARADIGM: CO-ADAPTATION BASED ON REINFORCEMENT LEARNING By
Digiovanna, J. F. (2008)
Long-term decoding of arm movement using Spatial Distribution of Neural Patterns
Tadipatri, V. A., Tewfik, A. H., & Ashe, J. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943920
Moxon, K. A. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5227-0_3
Adaptive real-time decoding of brain signals for long-term control of a neuro-prosthetic device
Dharampal, T. A. (2011) · e-Publications@Marquette (Marquette University)
Modification of an asynchronous dexterous hand movement decoder for hardware implementation
Bosen, A. K. (2010) · RIT Scholar Works (Rochester Institute of Technology)
Neely, R. (2017) · eScholarship (California Digital Library)
Spatial and temporal structure of choice representations in primate prefrontal cortexPreprint
Kollmorgen, S., Newsome, W. T., & Mante, V. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/595520
“For clusters returned by this post-processing, both 563 spike-waveform and spike-timing metrics fell within previously-reported ranges for array recordings 564 (Suner et al., 2005).”
BackgroundLian, Q., Liu, Y., Zhao, Y., & Qi, Y. (2021) · Communications in computer and information science · doi:10.1007/978-981-16-1288-6_4
Operant Conditioning of Single Neuron Activity in Brain-Machine Interfaces
Garcia, G., & Gabriela, M. (2020)
Stephens, T., Cafaro, J., MacRae, R., & Simons, S. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.05.18.444641
“The observed spikes measured with MEAs can change for many reasons including: electrode malfunction or movement, local neuron death or adaptation [5-18].”
BackgroundMylavarapu, R. V., Prins, N. W., Pohlmeyer, E. A., Shoup, A. M., Debnath, S., Geng, S., Sanchez, J. C., Schwartz, O., & Prasad, A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac115c
“[17, 28, 70–72].”
Peripheral Nerve Interface Applications, EMG/ENG
Abdelghani, M., Abbas, J. J., & Jung, R. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_199
Gerasimenko, Y., & Edgerton, V. R. (2015) · Encyclopedia of Computational Neuroscience · doi:10.1007/978-1-4614-6675-8_591
Gerasimenko, Y., & Edgerton, V. R. (2013) · Encyclopedia of Computational Neuroscience · doi:10.1007/978-1-4614-7320-6_591-1
Metadata
- Authors
- Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P.
- Affiliations
- Brown University (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2005-12
- Volume
- 13
- Issue
- 4
- Pages
- 524-541
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2113853842
- Cited by
- 415
- References
- 30
- Citations by year
- 2026: 6 · 2025: 17 · 2024: 12 · 2023: 13 · 2022: 13 · 2021: 25 · 2020: 10 · 2019: 15 · 2018: 25 · 2017: 23 · 2016: 19 · 2015: 28 · 2014: 36 · 2013: 26 · 2012: 16
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (NS-25074)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- chronic neural recording, primary motor cortex, non-human primates, macaque, signal-to-noise ratio, neuroprosthetics, parietal cortex, long-term implantation
- MeSH terms
- Action Potentials, Animals, Electrodes, Implanted, Electroencephalography, Equipment Design, Female, Humans, Macaca mulatta, Male, Microelectrodes, Motor Cortex, Primates, Sensitivity and Specificity, Silicon, Reproducibility of Results, Evoked Potentials, Motor, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review