The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.
Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex
Abstract
Multiple-electrode arrays are valuable both as a research tool and as a sensor for neuromotor prosthetic devices, which could potentially restore voluntary motion and functional independence to paralyzed humans. Long-term array reliability is an important requirement for these applications. Here, we demonstrate the reliability of a regular array of 100 microelectrodes to obtain neural recordings from primary motor cortex (MI) of monkeys for at least three months and up to 1.5 years. We implanted Bionic (Cyberkinetics, Inc., Foxboro, MA) silicon probe arrays in MI of three Macaque monkeys. Neural signals were recorded during performance of an eight-direction, push-button task. Recording reliability was evaluated for 18, 35, or 51 sessions distributed over 83, 179, and 569 days after implantation, respectively, using qualitative and quantitative measures. A four-point signal quality scale was defined based on the waveform amplitude relative to noise. A single observer applied this scale to score signal quality for each electrode. A mean of 120 (+/- 17.6 SD), 146 (+/- 7.3), and 119 (+/- 16.9) neural-like waveforms were observed from 65-85 electrodes across subjects for all recording sessions of which over 80% were of high quality. Quantitative measures demonstrated that waveforms had signal-to-noise ratio (SNR) up to 20 with maximum peak-to-peak amplitude of over 1200 microv with a mean SNR of 4.8 for signals ranked as high quality. Mean signal quality did not change over the duration of the evaluation period (slope 0.001, 0.0068 and 0.03; NS). By contrast, neural waveform shape varied between, but not within days in all animals, suggesting a shifting population of recorded neurons over time. Arm-movement related modulation was common and 66% of all recorded neurons were tuned to reach direction. The ability for the array to record neural signals from parietal cortex was also established. These results demonstrate that neural recordings that can provide movement related signals for neural prostheses, as well as for fundamental research applications, can be reliably obtained for long time periods using a monolithic microelectrode array in primate MI and potentially from other cortical areas as well.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In fact, after appropriate control in experimental models to test their biocompatibility and efficacy [18], LIFEs have been recently used to control artificial devices [6,7,22-25] showing good results during short-term trials with human amputees.”
From Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces (2011) · cites this paper as [22]
In the citing paper
“These trials showed that subjects are able to control a one-degree of freedom hand prosthesis through online processing of the efferent neural signals, and that repeatable sensory feedback may be received by stimulating afferent fibers [22,23] corresponding to the missing hand/fingers territories.”
From Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces (2011) · cites this paper as [22]
Citations
Cites
Visual Feature Integration and the Temporal Correlation Hypothesis
Singer, W., & Gray, C. M. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.003011 · Cited by 3,217
Georgopoulos, A. P., Kalaska, J. F., Caminiti, R., & Massey, J. (1982) · Journal of Neuroscience · doi:10.1523/jneurosci.02-11-01527.1982 · Cited by 2,133
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,542
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,415
Self-citationBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 811
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 603
Fabrication and biocompatibility of polypyrrole implants suitable for neural prosthetics.
George, P. M., Lyckman, A., Laván, D., Hegde, A., Leung, Y., Avasare, R., Testa, C., Alexander, P. M., Langer, R., & Sur, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.037 · Cited by 560
Research works printed but not linked: 1
- Horch, 2002, World Scientific
Cited by
Sorted by citations
Items 101–200 of 414
Agorelius, J., Tsanakalis, F., Friberg, A., Thorbergsson, P. T., Pettersson, L. M. E., & Schouenborg, J. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00331 · Cited by 86
“In Suner et al. (2005), this validation was performed by visual inspection of unit-waveforms, and by rejecting units that did not have at least a biphasic component.”
BackgroundMethodInfluentialEvaluation of the stability of intracortical microelectrode arrays
Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.870495 · Cited by 84
“implantation techniques have also made it possible for the implanted microelectrodes to achieve a long-term interface with the neural tissue [7]–[12].”
BackgroundLai, H., Liao, L., Lin, C., Hsu, J.-H., He, X., Chen, Y., Chang, J.-Y., Chen, H.-F., Tsang, S., & Shih, Y. I. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036001 · Cited by 83
“The in vivo electrode–electrolyte interface impedance (at 1 kHz) was measured to detect chronic tissue proliferation around the electrodes (Suner et al 2005).”
MethodInterim Safety Profile From the Feasibility Study of the BrainGate Neural Interface System
Rubin, D. B., Ajiboye, A. B., Barefoot, L., Bowker, M., Cash, S. S., Chen, D., Donoghue, J. P., Eskandar, E. N., Friehs, G., Grant, C., et al. (2023) · Neurology · doi:10.1212/wnl.0000000000201707 · Cited by 81
Self-citationWireless multi-channel single unit recording in freely moving and vocalizing primates
Roy, S., & Wang, X. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.09.004 · Cited by 83
Jackson, A., Mavoori, J., & Fetz, E. E. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00710.2006 · Cited by 83
Smaller, softer, lower-impedance electrodes for human neuroprosthesis: a pragmatic approach
Castagnola, E., Ansaldo, A., Maggiolini, E., Ius, T., Škrap, M., Ricci, D., & Fadiga, L. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00008 · Cited by 82
“METHODS ARTICLE published: 16 April 2014 doi: 10.3389/fneng.2014.00008 Smaller, softer, lower-impedance electrodes for human neuroprosthesis: a pragmatic approach”
BackgroundInfluentialDecoding Local Field Potentials for Neural Interfaces
Andrew, J. O., & Hall, T. M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2612001 · Cited by 78
“to years [13], [14] and thus the performance of decoders”
BackgroundWireless and battery-free platforms for collection of biosignals
Stuart, T., Cai, L., Burton, A., & Gutruf, P. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113007 · Cited by 78
“, 2009) that often require bulky connectors and ports (Suner et al., 2005) to supply power to the device and allow transmission of high-fidelity recorded signals.”
Do Electrode Properties Create a Problem in Interpreting Local Field Potential Recordings?
Nelson, M. J., & Pouget, P. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00157.2010 · Cited by 77
“These views are not established facts, however, and there is at least some contrary evidence in the literature (Suner et al. 2005).”
Brochier, T. G., Zehl, L., Hao, Y., Duret, M., Sprenger, J., Denker, M., Grün, S., & Alexa Riehle, C. (2018) · Scientific Data · doi:10.1038/sdata.2018.55 · Cited by 76
Kellis, S., House, P. A., Thomson, K. E., Brown, R. B., & Greger, B. E. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0974 · Cited by 75
Implantable Neural Probes for Brain-Machine Interfaces ? Current Developments and Future Prospects
Choi, J., Kim, S., Ryu, R.-H., Kim, S.-P., & Sohn, J.-W. (2018) · Experimental Neurobiology · doi:10.5607/en.2018.27.6.453 · Cited by 77
Bioinspired Prosthetic Interfaces
Li, P., Ali, H. P. A., Cheng, W. M., Yang, J., & Tee, B. C. K. (2020) · Advanced Materials Technologies · doi:10.1002/admt.201900856 · Cited by 76
Ince, N. F., Gupta, R., Arıca, S., Tewfik, A. H., Ashe, J., & Pellizzer, G. (2010) · PLoS ONE · doi:10.1371/journal.pone.0014384 · Cited by 76
“5 years [32,33].”
Acharya, S., Tenore, F. V., Aggarwal, V., Etienne‐Cummings, R., Schieber, M. H., & Thakor, N. V. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916269 · Cited by 72
“In a long term study, the Utah array has been reported to record activity from an average of 1.3 units per recording site [ 27 ].”
BackgroundInfluentialSignal Processing Challenges for Neural Prostheses
Linderman, M. D., Santhanam, G., Kemere, C. T., Gilja, V., O’Driscoll, S., Yu, B. M., Afshar, A., Ryu, S. I., Shenoy, K. V., & Meng, T. H. Y. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408439 · Cited by 75
“These changes in action potential shape have been previously observed across once-daily recordings [28].”
BackgroundRobust and accurate decoding of hand kinematics from entire spiking activity using deep learning
Ahmadi, N., Constandinou, T. G., & Bouganis, C.-S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abde8a · Cited by 69
Rizk, M., Obeid, I., Callender, S. H., & Wolf, P. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/016 · Cited by 71
“Today’s neural data acquisition systems have been effective in simultaneously recording extracellular potentials from hundreds of neurons [1–3].”
Long-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
“12 while others demonstrate no correlation between impedance and signal quality [5, 6, 105].”
BackgroundBioactive properties of nanostructured porous silicon for enhancing electrode to neuron interfaces
Moxon, K. A., Hallman, S. J., Aslani, A., Kalkhoran, N. M., & Lelkes, P. I. (2007) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856207782177882 · Cited by 69
Bioimpedance modeling to monitor astrocytic response to chronically implanted electrodes
McConnell, G. C., Butera, R. J., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/055005 · Cited by 68
“noise ratio (SNR) and |Z|1 kHz were negatively correlated within each monkey, but not across monkeys [37].”
BackgroundThe “sewing machine” for minimally invasive neural recordingPreprint
Hanson, T., Diaz-Botia, C. A., Kharazia, V., Maharbiz, M. M., & Sabes, P. N. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/578542 · Cited by 68
“The capillary bed in primate cortex is very dense, with microcapilaries spaced at 40 μm [33], and nearly a meter of vasculature per microliter”
BackgroundDu, Z. J., Luo, X., Weaver, C. L., & Cui, X. T. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00145e · Cited by 70
Evidence for a neural law of effect
Athalye, V. R., Santos, F. J., Carmena, J. M., & Costa, R. M. (2018) · Science · doi:10.1126/science.aao6058 · Cited by 75
Robust Neuroprosthetic Control from the Stroke Perilesional Cortex
Gulati, T., Won, S. J., Ramanathan, D., Wong, C. C., Bodepudi, A., Swanson, R. A., & Ganguly, K. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.5007-14.2015 · Cited by 70
“Where A is the peak-to-peak voltage of the averaged spike waveform and SDnoise is the SD of the noise (Suner et al., 2005).”
Chronic intracortical neural recordings using microelectrode arrays coated with PEDOT–TFB
Charkhkar, H., Knaack, G. L., McHail, D. G., Mandal, H. S., Peixoto, N., Rubinson, J. F., Dumas, T. C., & Pancrazio, J. J. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.12.022 · Cited by 68
Sponheim, C., Papadourakis, V., Collinger, J. L., Downey, J., Weiss, J., Pentousi, L., Elliott, K., & Hatsopoulos, N. G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3eaf · Cited by 66
Refinement of learned skilled movement representation in motor cortex deep output layer
Li, Q., Ko, H., Qian, Z., Yan, L. Y. C., Chan, D. C. W., Arbuthnott, G. W., Ke, Y., & Yung, W. (2017) · Nature Communications · doi:10.1038/ncomms15834 · Cited by 68
Cortical stimulation mapping using epidurally implanted thin-film microelectrode arrays
Molina-Luna, K., Buitrago, M. M., Hertler, B., Schubring-Giese, M., Haiss, F., Nisch, W., Schulz, J. B., & Luft, A. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.10.025 · Cited by 64
Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality
Purcell, E. K., Thompson, D. E., Ludwig, K. A., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.026 · Cited by 62
Zhang, S., Song, Y., Wang, M., Zhang, Z., Fan, X., Song, X., Zhuang, P., Yue, F., Chan, P., & Cai, X. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.04.087 · Cited by 64
Let There Be Light—Optoprobes for Neural Implants
Alt, M. T., Fiedler, E., Rudmann, L., Ordonez, J. S., Ruther, P., & Stieglitz, T. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2577518 · Cited by 63
Zhang, S., Song, Y., Wang, M., Xiao, G., Gao, F., Li, Z., Tao, G., Zhuang, P., Yue, F., Chan, P., et al. (2018) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.70 · Cited by 62
Progress in the Field of Micro-Electrocorticography
Shokoueinejad, M., Park, D., Jung, Y. H., Brodnick, S. K., Novello, J., Dingle, A. M., Swanson, K. I., Baek, D.-H., Suminski, A. J., Lake, W. B., et al. (2019) · Micromachines · doi:10.3390/mi10010062 · Cited by 65
“Utah 10 × 10 3D array Doped Si Pt/Ir 1600 μm 2 100–750 kΩ Tip exposed (40 μm) Primary motor cortex (M1, monkey) [80] (2005)”
Volitional Modulation of Primary Visual Cortex Activity Requires the Basal Ganglia
Neely, R., Koralek, A. C., Athalye, V. R., Costa, R. M., & Carmena, J. M. (2018) · Neuron · doi:10.1016/j.neuron.2018.01.051 · Cited by 62
Ultracompliant Hydrogel‐Based Neural Interfaces Fabricated by Aqueous‐Phase Microtransfer Printing
Huang, W., Ong, X. C., Kwon, I. S., Gopinath, C., Fisher, L. E., Wu, H., Fedder, G. K., Gaunt, R. A., & Bettinger, C. J. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201801059 · Cited by 61
Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis
Colachis, S. C., Dunlap, C. F., Annetta, N. V., Tamrakar, S., Bockbrader, M. A., & Friedenberg, D. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1add · Cited by 67
Defining Surgical Terminology and Risk for Brain Computer Interface Technologies
Leuthardt, E. C., Moran, D. W., & Mullen, T. R. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.599549 · Cited by 62
“…degraded ability to record neuronal spiking over a relatively short period of time due to astrocytic responses including glial encapsulation around electrodes (Turner et al., 1999; Suner et al., 2005; Bjornsson et al., 2006; Seymour and Kipke, 2007; Flesher et al., 2017; Salatino et al., 2017).”
BackgroundEngineered Axonal Tracts as “Living Electrodes” for Synaptic‐Based Modulation of Neural Circuitry
Serruya, M. D., Harris, J. P., Adewole, D. O., Struzyna, L. A., Burrell, J. C., Nemes, A. D., Petrov, D., Kraft, R. H., Chen, H.-C. I., Wolf, J. A., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201701183 · Cited by 62
Cutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 58
Wang, D., Zhang, Q., Li, Y., Wang, Y., Zhu, J., Zhang, S., & Zheng, X. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036009 · Cited by 60
“Our results showed that the number of spikes recorded decreased over time, which was consistent with previous studies [47, 65].”
Decoding the rat forelimb movement direction from epidural and intracortical field potentials
Slutzky, M. W., Jordan, L. R., Lindberg, E. W., Lindsay, K. E., & Miller, L. E. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036013 · Cited by 59
“However, current intracortical electrodes typically record single-unit spikes for no more than 1-3 years [21, 22].”
BackgroundNeural Probes for Chronic Applications
Kook, G., Lee, S., Lee, H., Cho, I., & Lee, H. J. (2016) · Micromachines · doi:10.3390/mi7100179 · Cited by 61
Barz, F., Livi, A., Lanzilotto, M., Maranesi, M., Bonini, L., Paul, O., & Ruther, P. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a90 · Cited by 59
“For other Si-based probes, stable operation over extended periods has been demonstrated [41, 42].”
BackgroundPropagation of Epileptiform Activity on a Submillimeter Scale
Schevon, C. A., Goodman, R. R., McKhann, G. M., & Emerson, R. G. (2010) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3181fdf8a1 · Cited by 58
“Single-neuron firing was detected using spike sorting software from Blackrock Microsystems, Inc. (Hochberg et al., 2006; Suner et al., 2005).”
Grahn, P. J., Mallory, G. W., Berry, B. M., Hachmann, J. T., Lobel, D. A., & Luján, J. L. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00296 · Cited by 60
Grobman, M., Dalal, T., Lavian, H., Shmuel, R., Belelovsky, K., Xu, F., Korngreen, A., & Haddad, R. (2018) · Neuron · doi:10.1016/j.neuron.2018.07.012 · Cited by 57
An automated behavioral box to assess forelimb function in rats
Wong, C. C., Ramanathan, D., Gulati, T., Won, S. J., & Ganguly, K. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.03.008 · Cited by 55
Interfacing With the Computational Brain
Andrew, J. O., & Fetz, E. E. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2158586 · Cited by 57
Stiller, A. M., Usoro, J. O., Frewin, C. L., Danda, V. R., Ecker, M., Joshi‐Imre, A., Musselman, K. C., Voit, W. E., Modi, R., Pancrazio, J. J., et al. (2018) · Micromachines · doi:10.3390/mi9100500 · Cited by 56
Tseng, W.-T., Yen, C., & Tsai, M. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.08.028 · Cited by 54
“5 years has been reported using silicone-base microelectrode in primate motor cortex (Suner et al., 2005).”
BackgroundMalaga, K. A., Schroeder, K. E., Patel, P. R., Irwin, Z. T., Thompson, D. E., Bentley, J. N., Lempka, S. F., Chestek, C. A., & Patil, P. G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016010 · Cited by 55
“between impedance and signal quality [7, 18, 26].”
Implantable brain computer interface: Challenges to neurotechnology translation
Konrad, P. E., & Shanks, T. (2009) · Neurobiology of Disease · doi:10.1016/j.nbd.2009.12.007 · Cited by 58
Chronic impedance spectroscopy of an endovascular stent-electrode array
Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Grayden, D. B., Burkitt, A. N., May, C. N., O'Brien, T. J., & Oxley, T. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046020 · Cited by 54
Gaunt, R. A., Hokanson, J. A., & Weber, D. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/055009 · Cited by 53
“5 years (Suner et al., 2005), but in the DRG, stable recordings have persisted for at most several weeks (Weber et al.”
BackgroundTrends and recent development of the microelectrode arrays (MEAs)
Xu, L., Hu, C., Huang, Q., Jin, K., Zhao, P., Wang, D., Hou, W., Dong, L., Hu, S., & Ma, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112854 · Cited by 56
Khilwani, R., Gilgunn, P. J., Kozai, T. D. Y., Ong, X. C., Korkmaz, E., Gunalan, P. K., Cui, X. T., Fedder, G. K., & Özdoğanlar, O. B. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0125-4 · Cited by 51
Data Compression in Brain-Machine/Computer Interfaces Based on the Walsh–Hadamard Transform
Hosseini‐Nejad, H., Jannesari, A., & Sodagar, A. M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2258669 · Cited by 49
Chun, W., Chou, N., Cho, S., Yang, S. H., & Kim, S. (2013) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2013.11.020 · Cited by 48
Long-term stability of sensitivity to intracortical microstimulation of somatosensory cortex
Callier, T., Schluter, E. W., Tabot, G. A., Miller, L. E., Tenore, F. V., & Bensmaı̈a, S. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056010 · Cited by 48
Szymanski, L. J., Kellis, S., Liu, C. Y., Jones, K. T., Andersen, R. A., Commins, D., Lee, B., McCreery, D. B., & Miller, C. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac127e · Cited by 48
The functional consequences of chronic, physiologically effective intracortical microstimulation
Parker, R., Davis, T. S., House, P. A., Normann, R. A., & Greger, B. E. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00010-8 · Cited by 48
“4 and 5), the number of action potentials recorded from motor cortex followed a previously observed pattern of initially increasing followed by a decrease in numbers over the course of months (Suner et al., 2005).”
BackgroundNeural prosthetic systems: Current problems and future directions
Chestek, C. A., Cunningham, J. P., Gilja, V., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332822 · Cited by 44
“2) Waveform Shape Instability: While there is evidence that neurons themselves maintain stable tuning properties at least over the course of a day [28], there is significant doubt about the stability of the raw voltage recordings of those neurons over the same time periods (due to changing position of the electrodes w…”
BackgroundFeingold, J., Desrochers, T. M., Fujii, N., Harlan, R., Tierney, P. L., Shimazu, H., Amemori, K., & Graybiel, A. M. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00625.2011 · Cited by 47
“We found that all of the clusters had an SNR 2, which, using a previously published categoriza- tion procedure (Suner et al. 2005), suggested that all of the units could be classified as “good” or “fair”, as opposed to “poor” (Fig.”
BackgroundMethodInfluentialHarris, A. R., Molino, P. J., Kapsa, R. M. I., Clark, G. M., Paolini, A. G., & Wallace, G. G. (2015) · The Analyst · doi:10.1039/c4an02362e · Cited by 46
Lee, B., Liu, C. Y., & Apuzzo, M. L. J. (2013) · World Neurosurgery · doi:10.1016/j.wneu.2013.01.078 · Cited by 46
Spike Train SIMilarity Space (SSIMS): A Framework for Single Neuron and Ensemble Data Analysis
Vargas-Irwin, C. E., Brandman, D. M., Zimmermann, J. B., Donoghue, J. P., & Black, M. J. (2014) · Neural Computation · doi:10.1162/neco_a_00684 · Cited by 44
Self-citationXu, H., Weltman, A., Scholten, K., Berger, T. W., Song, D. B., & Meng, E. F. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9451 · Cited by 48
Mental Workload Estimation Based on Physiological Features for Pilot-UAV Teaming Applications
Singh, G., Chanel, C. P. C., & Roy, R. N. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.692878 · Cited by 45
Samonds, J. M., Potetz, B. R., & Lee, T. S. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1200125109 · Cited by 44
“First, we recorded from neurons using a 10 × 10 Utah Intracortical Array (400-μm spacing), using methods described previously (50, 51).”
BackgroundMethodDecoding Movement Intent From Human Premotor Cortex Neurons for Neural Prosthetic Applications
Ojakangas, C. L., Shaikhouni, A., Friehs, G. M., Caplan, A. H., Serruya, M. D., Saleh, M., Morris, D. S., & Donoghue, J. P. (2006) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000233323.87127.14 · Cited by 44
“Chronically implanted arrays capable of recording dozens of cells (Paninski et al., 2004) have been tested in monkeys (Serruya et al., 2002; Suner et al., 2005) and in a human (Mukand et al., 2004).”
BackgroundSelf-citationSharma, G., Annetta, N., Friedenberg, D., Blanco, T., Vasconcelos, D., Shaikhouni, A., Rezai, A. R., & Bouton, C. (2015) · Bioelectronic Medicine · doi:10.15424/bioelectronmed.2015.00010 · Cited by 41
Vargas-Irwin, C. E., Franquemont, L., Black, M. J., & Donoghue, J. P. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.1574-15.2015 · Cited by 44
“Each electrode array contained a 4 4 mm grid with 96 active silicon-based electrodes 1 mm in length and spaced 400 m apart (for details on array structure and surgical procedures, see Suner et al., 2005; Barrese et al., 2013).”
MethodSelf-citationKoch, J., Schüettler, M., Pasluosta, C. F., & Stieglitz, T. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab36df · Cited by 44
Local and Global Correlations between Neurons in the Middle Temporal Area of Primate Visual Cortex
Solomon, S. S., Chen Spencer, C., Morley, J. W., & Solomon, S. G. (2014) · Cerebral Cortex · doi:10.1093/cercor/bhu111 · Cited by 42
Robust penetrating microelectrodes for neural interfaces realized by titanium micromachining
McCarthy, P. T., Otto, K. J., & Rao, M. P. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9519-5 · Cited by 50
“The signal-tonoise ratio was 6.64, which is comparable to “good” recordings from conventional silicon-based microelectrode arrays (Suner et al. 2005).”
BackgroundMethodInfluentialCharacterizing neural dependencies with copula models
Berkes, P., Wood, F., & Pillow, J. W. (2008) · Cited by 41
Fernández, E., Alfaro, A., & González-López, P. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00681 · Cited by 35
Multichannel Electrophysiological Spike Sorting via Joint Dictionary Learning and Mixture Modeling
Carlson, D., Vogelstein, J. T., Wu, Q., Lian, W., Zhou, M., Stoetzner, C. R., Kipke, D. R., Weber, D. J., Dunson, D. B., & Carin, L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2275751 · Cited by 42
Tankus, A., Yeshurun, Y., & Fried, I. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056001 · Cited by 41
“Human classifiers rely on visual inspection as their main evaluation tool (see for example Vargas-Irwin and Donoghue (2007), Rutishauser et al (2006), Tankus et al (2009), Stark and Abeles (2007), Suner et al (2005), Kim et al (2008)).”
MethodKim, T., Branner, A., Gulati, T., & Giszter, S. F. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045001 · Cited by 39
“To calculate the signal-tonoise ratio (SNR), we used the following equation described by Suner et al [36]:”
Cue to action processing in motor cortex populations
Rao, N. G., & Donoghue, J. P. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00274.2013 · Cited by 42
Self-citationResearch Progress on the Flexibility of an Implantable Neural Microelectrode
Zhao, H., Liu, R., Zhang, H., Cao, P., Liu, Z., & Li, Y. (2022) · Micromachines · doi:10.3390/mi13030386 · Cited by 37
Temporal Processing in the Visual Cortex of the Awake and Anesthetized Rat
Aasebø, I. E. J., Lepperød, M. E., Stavrinou, M., Nøkkevangen, S., Einevoll, G. T., Hafting, T., & Fyhn, M. (2017) · eNeuro · doi:10.1523/eneuro.0059-17.2017 · Cited by 38
“To ensure that other cell classes did not interfere with the classification of units, the following units were excluded: units that reached signal saturation, that had a low signal-to-noise ratio (SNR 2.75; Suner et al., 2005; Smith and Kohn, 2008), or units that showed the triphasic wave form typically associated wit…”
BackgroundInfluentialCaldwell, R., Mandal, H. S., Sharma, R., Solzbacher, F., Tathireddy, P., & Rieth, L. W. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa69d3 · Cited by 36
Neural electrodes for brain‐computer interface system: From rigid to soft
Yang, D., Tian, G., Chen, J., Liu, Y., Fatima, E., Qiu, J., Malek, N. A. N. N., & Qi, D. (2025) · BMEMat · doi:10.1002/bmm2.12130 · Cited by 37
An Implantable Neural Sensing Microsystem with Fiber-Optic Data Transmission and Power Delivery
Park, S., Borton, D. A., Kang, M., Nurmikko, A. V., & Song, Y. (2013) · Sensors · doi:10.3390/s130506014 · Cited by 34
“For example, chronically implanted, multielectrode arrays have allowed long term (>1 year) exploration of reach and grasp representation in the motor cortex of rhesus macaques [4].”
BackgroundAssessment of gliosis around moveable implants in the brain
Stice, P., & Muthuswamy, J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046004 · Cited by 34
Semiconducting electrodes for neural interfacing: a review
Ahnood, A., Chambers, A., Gelmi, A. A., Yong, K., & Kavehei, O. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00830k · Cited by 33
Magnetically Inserted Neural Electrodes: Tissue Response and Functional Lifetime
Dryg, I., Ward, M. P., Qing, K. Y., Mei, H., Schaffer, J. E., & Irazoqui, P. P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2399856 · Cited by 33
“Spike sorting was performed using Osort [28], and signal-to-noise ratio (SNR) was calculated as previously described [29]”
MethodHu, Y., Yang, G., Liang, B., Lü, F., Ma, G., Zhu, Q. Y., Chen, S., & Ye, X. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.11.023 · Cited by 32
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation
Usoro, J. O., Sturgill, B. S., Musselman, K. C., Capadona, J. R., & Pancrazio, J. J. (2021) · Micromachines · doi:10.3390/mi12080972 · Cited by 34
An Ultraflexible Electrode Array for Large‐Scale Chronic Recording in the Nonhuman Primate Brain
Tian, Y., Yin, J., Wang, C., He, Z., Xie, J., Feng, X., Zhou, Y., Ma, T., Xie, Y., Li, X., et al. (2023) · Advanced Science · doi:10.1002/advs.202302333 · Cited by 32
Frampton, J. P., Hynd, M. R., Williams, J. C., Shuler, M. L., & Shain, W. G. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/006 · Cited by 31
Carbon‐Nanotube‐Modified Electrodes for Highly Efficient Acute Neural Recording
Shin, J. H., Kim, G. B., Lee, E. J., An, T., Shin, K., Lee, S. E., Choi, W., Lee, S., Latchoumane, C.-F. V., Shin, H., et al. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201300183 · Cited by 30
Bjånes, D. A., Kellis, S., Nickl, R., Baker, B., Aflalo, T., Bashford, L., Chivukula, S., Fifer, M. S., Osborn, L. E., Christie, B., et al. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.02.030 · Cited by 37
“However, longitudinal BCI performance from intracortical microelectrodes (such as the “ Utah ” array) varies widely between participants, as recording quality deteriorates over time [23, 25 – 28].”
Neural Recording Stability of Chronic Electrode Arrays in Freely Behaving Primates
Linderman, M. D., Gilja, V., Santhanam, G., Afshar, A., Ryu, S. I., Meng, T. H. Y., & Shenoy, K. V. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260814 · Cited by 29
“The HermesB system, a new autonomous, long-duration neural recording system for freely behaving non-human primates, enables collection of the previously unavailable multi-day broadband datasets needed for this characterization [2].”
BackgroundElectrothermal Microactuators With Peg Drive Improve Performance for Brain Implant Applications
Anand, S., Sutanto, J., Baker, M. S., Okandan, M., & Muthuswamy, J. (2012) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2012.2203789 · Cited by 28
Paralikar, K. J., Rao, C. R., & Clement, R. S. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.04.014 · Cited by 28
“Neural spiking events are typically detected using a pre-defined threshold on the recorded electrode followed by template-matching, Principal Component Analysis(PCA), clustering techniques, or Bayesian filters (Chapin et al., 1999; Isaacs et al., 2000; Lewicki, 1998; Rennaker et al., 2005; Suner et al., 2005) to selec…”
Method
Metadata
- Authors
- Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P.
- Affiliations
- Brown University (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2005-12
- Volume
- 13
- Issue
- 4
- Pages
- 524-541
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2113853842
- Cited by
- 415
- References
- 30
- Citations by year
- 2026: 6 · 2025: 17 · 2024: 12 · 2023: 13 · 2022: 13 · 2021: 25 · 2020: 10 · 2019: 15 · 2018: 25 · 2017: 23 · 2016: 19 · 2015: 28 · 2014: 36 · 2013: 26 · 2012: 16
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (NS-25074)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- chronic neural recording, primary motor cortex, non-human primates, macaque, signal-to-noise ratio, neuroprosthetics, parietal cortex, long-term implantation
- MeSH terms
- Action Potentials, Animals, Electrodes, Implanted, Electroencephalography, Equipment Design, Female, Humans, Macaca mulatta, Male, Microelectrodes, Motor Cortex, Primates, Sensitivity and Specificity, Silicon, Reproducibility of Results, Evoked Potentials, Motor, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review