Cortically coupled computer vision for rapid image search
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We describe a real-time electroencephalography (EEG)-based brain-computer interface system for triaging imagery presented using rapid serial visual presentation. A target image in a sequence of nontarget distractor images elicits in the EEG a stereotypical spatiotemporal response, which can be detected. A pattern classifier uses this response to reprioritize the image sequence, placing detected targets in the front of an image stack. We use single-trial analysis based on linear discrimination to recover spatial components that reflect differences in EEG activity evoked by target versus nontarget images. We find an optimal set of spatial weights for 59 EEG sensors within a sliding 50-ms time window. Using this simple classifier allows us to process EEG in real time. The detection accuracy across five subjects is on average 92%, i.e., in a sequence of 2500 images, resorting images based on detector output results in 92% of target images being moved from a random position in the sequence to one of the first 250 images (first 10% of the sequence). The approach leverages the highly robust and invariant object recognition capabilities of the human visual system, using single-trial EEG analysis to efficiently detect neural signatures correlated with the recognition event.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
(1966) · Medical Entomology and Zoology · Cited by 10,293
Signal detection theory and psychophysics
Ingleby, J. D. (1967) · Journal of Sound and Vibration · doi:10.1016/0022-460x(67)90197-6 · Cited by 8,509
Pragmatics of measuring recognition memory: Applications to dementia and amnesia.
Snodgrass, J. G., & Corwin, J. (1988) · Journal of Experimental Psychology General · doi:10.1037//0096-3445.117.1.34 · Cited by 3,089
Barker, L. (2002) · Technometrics · doi:10.1198/tech.2002.s659 · Cited by 2,477
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex
Chapin, J. K., Moxon, K. A., Markowitz, R. S., & Nicolelis, M. A. L. (1999) · Nature Neuroscience · doi:10.1038/10223 · Cited by 1,164
Independent component filters of natural images compared with simple cells in primary visual cortex
van Hateren, J. H., & van der Schaaf, A. (1998) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1998.0303 · Cited by 1,106
Cited by
Zander, T. O., & Kothe, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025005 · Cited by 887
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Neurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
The Berlin brain-computer Interface: accurate performance from first-session in BCI-naive subjects
Blankertz, B., Losch, F., Krauledat, M., Dornhege, G., Curio, G., & Muller, K.-R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923152 · Cited by 338
“For alternative applications of BCI technology, see [9]–[11]) .”
BackgroundErrare machinale est: the use of error-related potentials in brain-machine interfaces
Chavarriaga, R., Sobolewski, A., & Millán, J. D. R. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00208 · Cited by 311
Zakeri, H., Nejad, F. M., & Fahimifar, A. (2017) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-016-9194-z · Cited by 304
Interface, interaction, and intelligence in generalized brain–computer interfaces
Gao, X., Wang, Y., Chen, X., & Gao, S. (2021) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2021.04.003 · Cited by 304
A tactile P300 brain-computer interface
Brouwer (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00019 · Cited by 278
Brain Activity-Based Image Classification From Rapid Serial Visual Presentation
Bigdely-Shamlo, N., Vankov, A., Ramirez, R. R., & Makeig, S. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2003381 · Cited by 177
“[2], [14], [16] have recently demonstrated another use for EEG-based neurotechnology, to monitor participants’ brain responses while they are engaged in visual search through”
Separable Common Spatio-Spectral Patterns for Motor Imagery BCI Systems
Aghaei, A. S., Mahanta, M. S., & Plataniotis, K. N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2487738 · Cited by 165
A review of rapid serial visual presentation-based brain–computer interfaces
Lees, S., Dayan, N., Cecotti, H., McCullagh, P., Maguire, L., Lotte, F., & Coyle, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9817 · Cited by 149
A Collaborative Brain-Computer Interface for Improving Human Performance
Wang, Y., & Jung, T.-P. (2011) · PLoS ONE · doi:10.1371/journal.pone.0020422 · Cited by 147
Convolutional Neural Network for Multi-Category Rapid Serial Visual Presentation BCI
Manor, R., & Geva, A. B. (2015) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2015.00146 · Cited by 144
Cecotti, H., Eckstein, M. P., & Giesbrecht, B. (2014) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2014.2302898 · Cited by 109
“Although a difference was observed between motor and nonmotor tasks from 550 through 700 ms in [15], the”
BackgroundFuhrmann Alpert, G., Manor, R., Spanier, A. B., Deouell, L. Y., & Geva, A. B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2289898 · Cited by 74
“Unfortunately, classification numbers in the benchmark study of Parra et al. ([19]) were not provided, but target detection was shown to improve significantly after the EEG triage.”
BackgroundMethodInfluentialWang, Z., Chen, C., Li, J., Wan, F., Sun, Y., & Wang, H. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3237319 · Cited by 75
“5) Spatially Weighted FLD-PCA (SWFP) is designed for single trial ERP detection, which outperformed than Hierarchical Discriminant Component Analysis (HDCA) [39] and Hierarchical Discriminant Principal Component Analysis Algorithm (HDCPA) [40].”
MethodMarathe, A. R., Lawhern, V. J., Wu, D., Slayback, D., & Lance, B. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2502323 · Cited by 64
Cecotti, H., & Ries, A. J. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.07.500 · Cited by 50
Matran-Fernandez, A., & Poli, R. (2017) · PLOS ONE · doi:10.1371/journal.pone.0178498 · Cited by 45
Single-trial EEG RSVP classification using convolutional neural networks
Shamwell, J., Lee, H., Kwon, H., Marathe, A. R., Lawhern, V., & Nothwang, W. (2016) · SPIE Proceedings · doi:10.1117/12.2224172 · Cited by 34
Wei, W., Qiu, S., Zhang, Y., Mao, J., & He, H. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5eb7 · Cited by 24
“HDCA, a traditional subject-dependent RSVP-EEG decoding method, outperformed the compared subject-dependent methods.”
InfluentialCortically Coupled Computing: A New Paradigm for Synergistic Human-Machine Interaction
Saproo, S., Faller, J., Shih, V., Sajda, P., Waytowich, N. R., Bohannon, A., Lawhern, V. J., Lance, B. J., & Jangraw, D. (2016) · Computer · doi:10.1109/mc.2016.294 · Cited by 18
Self-citationWang, Z., Zhang, H., Ji, Z., Yang, Y., & Wang, H. (2023) · Brain Science Advances · doi:10.26599/bsa.2023.9050013 · Cited by 9
“By contrast, SWFP is designed for single-trial RSVP detection and exhibits better performance than hierarchical discriminant component analysis (HDCA) [14] and hierarchical discriminant principal component analysis algorithm (HDCPA) [15].”
MethodZhang, B., Xu, M., Zhang, Y., Ye, S., & Chen, Y. (2024) · Bioengineering · doi:10.3390/bioengineering11040347 · Cited by 4
“The rapid serial visual presentation-based brain–computer interface (RSVP-BCI) paradigm is based on the principle that the visual neural system elicits P300 event-related potentials in response to novel stimuli [1].”
Background
Metadata
- Authors
- Gerson, A. D., Parra, L. C., & Sajda, P.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2006-06
- Volume
- 14
- Issue
- 2
- Pages
- 174-179
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2163027455
- Cited by
- 258
- References
- 24
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.