Design and Control of RUPERT: A Device for Robotic Upper Extremity Repetitive Therapy
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
The structural design, control system, and integrated biofeedback for a wearable exoskeletal robot for upper extremity stroke rehabilitation are presented. Assisted with clinical evaluation, designers, engineers, and scientists have built a device for robotic assisted upper extremity repetitive therapy (RUPERT). Intense, repetitive physical rehabilitation has been shown to be beneficial overcoming upper extremity deficits, but the therapy is labor intensive and expensive and difficult to evaluate quantitatively and objectively. The RUPERT is developed to provide a low cost, safe and easy-to-use, robotic-device to assist the patient and therapist to achieve more systematic therapy at home or in the clinic. The RUPERT has four actuated degrees-of-freedom driven by compliant and safe pneumatic muscles (PMs) on the shoulder, elbow, and wrist. They are programmed to actuate the device to extend the arm and move the arm in 3-D space. It is very important to note that gravity is not compensated and the daily tasks are practiced in a natural setting. Because the device is wearable and lightweight to increase portability, it can be worn standing or sitting providing therapy tasks that better mimic activities of daily living. The sensors feed back position and force information for quantitative evaluation of task performance. The device can also provide real-time, objective assessment of functional improvement. We have tested the device on stroke survivors performing two critical activities of daily living (ADL): reaching out and self feeding. The future improvement of the device involves increased degrees-of-freedom and interactive control to adapt to a user's physical conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Nudo, R. J., Wise, B. M., SiFuentes, F., & Milliken, G. W. (1996) · Science · doi:10.1126/science.272.5269.1791 · Cited by 1,911
Nudo, R., Milliken, G., Jenkins, W., & Merzenich, M. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-02-00785.1996 · Cited by 1,413
Massive Cortical Reorganization After Sensory Deafferentation in Adult Macaques
Pons, T. P., Garraghty, P. E., Ommaya, A. K., Kaas, J. H., Taub, E., & Mishkin, M. (1991) · Science · doi:10.1126/science.1843843 · Cited by 1,086
Assessing Wolf Motor Function Test as Outcome Measure for Research in Patients After Stroke
Wolf, S. L., Catlin, P. A., Ellis, M., Archer, A. L., Morgan, B., & Piacentino, A. (2001) · Stroke · doi:10.1161/01.str.32.7.1635 · Cited by 1,051
van der Lee, J. H., Wagenaar, R. C., Lankhorst, G. J., Vogelaar, T. W., Devillé, W. L., & Bouter, L. M. (1999) · Stroke · doi:10.1161/01.str.30.11.2369 · Cited by 745
Nudo, R. J., & Milliken, G. W. (1996) · Journal of Neurophysiology · doi:10.1152/jn.1996.75.5.2144 · Cited by 715
Simonsen, C. (1998) · Neurology Report · doi:10.1097/01253086-199822020-00019 · Cited by 609
Role of adaptive plasticity in recovery of function after damage to motor cortex
Nudo, R. J., Plautz, E. J., & Frost, S. B. (2001) · Muscle & Nerve · doi:10.1002/mus.1104 · Cited by 561
Interjoint coordination during pointing movements is disrupted in spastic hemiparesis
Levin, M. F. (1996) · Brain · doi:10.1093/brain/119.1.281 · Cited by 477
Cited by
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522
Developments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
Robotic neurorehabilitation: a computational motor learning perspective
Huang, V. S., & Krakauer, J. W. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-5 · Cited by 425
Robot-assisted rehabilitation of hand function
Balasubramanian, S., Klein, J., & Burdet, E. (2010) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32833e99a4 · Cited by 287
Self-citationCui, X., Chen, W., Jin, X., & Agrawal, S. K. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2618888 · Cited by 204
“Conventional arm exoskeletons such as ARMin [8], RUPERT [9], L-EXOS [10], EXO-UL7 [11], [12], and MAHI [13] have serial/parallel rigid links.”
BackgroundRUPERT: An exoskeleton robot for assisting rehabilitation of arm functions
Balasubramanian, S., Wei, R., Perez, M., Shepard, B., Koeneman, E., Koeneman, J., & He, J. (2008) · 2008 Virtual Rehabilitation · doi:10.1109/icvr.2008.4625154 · Cited by 194
“The design of an earlier version (RUPERT III) has been described [11].”
MethodSelf-citationMechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties
Gopura, R. A. R. C., & Kiguchi, K. (2009) · 2009 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209630 · Cited by 192
“[52] Shoulder, elbow and wrist joints 04 Pneumatic muscles Pneumatics Upper extremity repetitive therapy”
BackgroundA soft wearable robot for the shoulder: Design, characterization, and preliminary testing
O'Neill, C. T., Phipps, N. S., Cappello, L., Paganoni, S., & Walsh, C. J. (2017) · 2017 International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2017.8009488 · Cited by 183
An Upper-Limb Power-Assist Exoskeleton Using Proportional Myoelectric Control
Tang, Z., Zhang, K., Sun, S., Gao, Z., Zhang, L., & Yang, Z. (2014) · Sensors · doi:10.3390/s140406677 · Cited by 182
“A four degrees-of-freedom system actuated by pneumatic muscles on the shoulder, elbow and wrist was built to assist the patients with achieving therapy at home or in the clinic [4], which was safe and easy to use.”
BackgroundA robotic system to train activities of daily living in a virtual environment
Guidali, M., Duschau-Wicke, A., Broggi, S., Klamroth-Marganska, V., Nef, T., & Riener, R. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0809-0 · Cited by 181
“Examples are Pneu-WREX [40], Rupert [36] and Dampace [35] for exoskeleton-based robots and the ADLER [13] and GENTLE/s [22] for end-effector-based devices.”
BackgroundVeale, A. J., & Xie, S. Q. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.01.010 · Cited by 160
Metadata
- Authors
- Sugar, T. G., He, J., Koeneman, E. J., Koeneman, J. B., Herman, R., Huang, H., Schultz, R. S., Herring, D. E., Wanberg, J., Balasubramanian, S., Swenson, P., & Ward, J. A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2007-09
- Volume
- 15
- Issue
- 3
- Pages
- 336-346
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2115435632
- Cited by
- 304
- References
- 25
- FWCI
- 11.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.