Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This paper introduces a newly developed gait rehabilitation device. The device, called LOPES, combines a freely translatable and 2-D-actuated pelvis segment with a leg exoskeleton containing three actuated rotational joints: two at the hip and one at the knee. The joints are impedance controlled to allow bidirectional mechanical interaction between the robot and the training subject. Evaluation measurements show that the device allows both a "patient-in-charge" and "robot-in-charge" mode, in which the robot is controlled either to follow or to guide a patient, respectively. Electromyography (EMG) measurements (one subject) on eight important leg muscles, show that free walking in the device strongly resembles free treadmill walking; an indication that the device can offer task-specific gait training. The possibilities and limitations to using the device as gait measurement tool are also shown at the moment position measurements are not accurate enough for inverse-dynamical gait analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Intensity of leg and arm training after primary middle-cerebral-artery stroke: a randomised trial
Kwakkel, G., Wagenaar, R. C., Twisk, J. W., Lankhorst, G. J., & Koetsier, J. C. (1999) · The Lancet · doi:10.1016/s0140-6736(98)09477-x · Cited by 938
Strategies for stroke rehabilitation
Dobkin, B. H. (2004) · The Lancet Neurology · doi:10.1016/s1474-4422(04)00851-8 · Cited by 738
Motor learning elicited by voluntary drive
Lotze, M. (2003) · Brain · doi:10.1093/brain/awg079 · Cited by 691 · cited 1×
“At the moment, determinants of successful gait training are largely unknown, although intensity [11], self-initiative [12] and task specificity [13], [14] seem to be important.”
BackgroundVeneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428 · cited 3×
“Impedance control implies that the interaction control is based on position sensing combined with force actuation [2], [17].”
BackgroundMethodThe Role of Task-Specific Training in Rehabilitation Therapies
Bayona, N. A., Bitensky, J., Salter, K., & Teasell, R. (2005) · Topics in Stroke Rehabilitation · doi:10.1310/bqm5-6ygb-mvj5-wvcr · Cited by 411
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
Motions or muscles? Some behavioral factors underlying robotic assistance of motor recovery
Hogan, N., Krebs, H. I., Rohrer, B., Palazzolo, J. J., Dipietro, L., Fasoli, S. E., Stein, J., Hughs, R., Frontera, W. R., Lynch, D., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0103 · Cited by 374
Upper and lower extremity robotic devices for rehabilitation and for studying motor control
Hesse, S., Schmidt, H., Werner, C., & Bardeleben, A. (2003) · Current Opinion in Neurology · doi:10.1097/00019052-200312000-00010 · Cited by 369
Israel, J. F., Campbell, D. D., Kahn, J. H., & Hornby, T. G. (2006) · Physical Therapy · doi:10.2522/ptj.20050266 · Cited by 322 · cited 1×
“The reason to omit an actuated robotic ankle joint was that it is not necessary to provide an external “ankle push-off” in the device in order to walk safely.”
BackgroundGait rehabilitation machines based on programmable footplates
Schmidt, H., Werner, C., Bernhardt, R., Hesse, S., & Krüger, J. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-2 · Cited by 256
Nilsson, L., Carlsson, J., Danielsson, A., Fugl-Meyer, A., Hellström, K., Kristensen, L., Sjölund, B., Sunnerhagen, K. S., & Grimby, G. (2001) · Clinical Rehabilitation · doi:10.1191/026921501680425234 · Cited by 235
Lum, P., Reinkensmeyer, D., Mahoney, R., Rymer, W. Z., & Burgar, C. (2002) · Topics in Stroke Rehabilitation · doi:10.1310/9kfm-kf81-p9a4-5ww0 · Cited by 218
A mechanized gait trainer for restoring gait in nonambulatory subjects
Hesse, S., Uhlenbrock, D., Werner, C., & Bardeleben, A. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2000.6280 · Cited by 193
HapticMaster – a generic force controlled robot for human interaction
van der Linde, R. Q., & Lammertse, P. (2003) · Industrial Robot: An International Journal · doi:10.1108/01439910310506783 · Cited by 165
Human-centered robotics applied to gait training and assessment
Riener, R., Lünenburger, L., & Colombo, G. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.02.0046 · Cited by 161
Tools for understanding and optimizing robotic gait training
Reinkensmeyer, D. J., Aoyagi, D., Emken, J. L., Galvez, J. A., Ichinose, W., Kerdanyan, G., Maneekobkunwong, S., Minakata, K., Nessler, J. A., Weber, R., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0073 · Cited by 146
Therapeutic Robotics: A Technology Push
Krebs, H. I., & Hogan, N. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.880721 · Cited by 138
LOPES : Selective Control of Gait Functions During the Gait Rehabilitation of CVA Patients
Ekkelenkamp, R., Veneman, J. F., & van der Kooij, H. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501120 · Cited by 80
Self-citationSelective control of a subtask of walking in a robotic gait trainer(LOPES)
Van Asseldonk, E. H. F., Ekkelenkamp, R., Veneman, J. F., Van der Helm, F. C. T., & van der Kooij, H. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428522 · Cited by 58
Self-citationDesign of a compliantly actuated exo-skeleton for an impedance controlled gait trainer robot
van der Kooij, H., Veneman, J. F., & Ekkelenkamp, R. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259397 · Cited by 41
Self-citationCompliant Actuation of Exoskeletons
van der Kooij, H., Veneman, J. F., & Ekkelenkamp, R. (2006) · doi:10.5772/4688 · Cited by 25
Self-citation
Cited by
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“This would exclude treadmill-based gait training orthoses such as the LOPES [19] and the Lokomat (Hocoma AG, Volketswil, Switzerland), which were among the classes of devices discussed in the review of Marchal-Crespo and Reinkensmeyer [20].”
Human-in-the-loop optimization of exoskeleton assistance during walking
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H. (2017) · Science · doi:10.1126/science.aal5054 · Cited by 1,011
Ham, R., Sugar, T., Vanderborght, B., Hollander, K., & Lefeber, D. (2009) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2009.933629 · Cited by 834
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Metadata
- Authors
- Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2007-09
- Volume
- 15
- Issue
- 3
- Pages
- 379-386
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2166869394
- Cited by
- 1,280
- References
- 24
- FWCI
- 15.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.