Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
This paper introduces a newly developed gait rehabilitation device. The device, called LOPES, combines a freely translatable and 2-D-actuated pelvis segment with a leg exoskeleton containing three actuated rotational joints: two at the hip and one at the knee. The joints are impedance controlled to allow bidirectional mechanical interaction between the robot and the training subject. Evaluation measurements show that the device allows both a "patient-in-charge" and "robot-in-charge" mode, in which the robot is controlled either to follow or to guide a patient, respectively. Electromyography (EMG) measurements (one subject) on eight important leg muscles, show that free walking in the device strongly resembles free treadmill walking; an indication that the device can offer task-specific gait training. The possibilities and limitations to using the device as gait measurement tool are also shown at the moment position measurements are not accurate enough for inverse-dynamical gait analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,290
Intensity of leg and arm training after primary middle-cerebral-artery stroke: a randomised trial
Kwakkel, G., Wagenaar, R. C., Twisk, J. W., Lankhorst, G. J., & Koetsier, J. C. (1999) · The Lancet · doi:10.1016/s0140-6736(98)09477-x · Cited by 938
Strategies for stroke rehabilitation
Dobkin, B. H. (2004) · The Lancet Neurology · doi:10.1016/s1474-4422(04)00851-8 · Cited by 738
Motor learning elicited by voluntary drive
Lotze, M. (2003) · Brain · doi:10.1093/brain/awg079 · Cited by 691 · cited 1×
“At the moment, determinants of successful gait training are largely unknown, although intensity [11], self-initiative [12] and task specificity [13], [14] seem to be important.”
BackgroundVeneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428 · cited 3×
“Impedance control implies that the interaction control is based on position sensing combined with force actuation [2], [17].”
BackgroundMethodThe Role of Task-Specific Training in Rehabilitation Therapies
Bayona, N. A., Bitensky, J., Salter, K., & Teasell, R. (2005) · Topics in Stroke Rehabilitation · doi:10.1310/bqm5-6ygb-mvj5-wvcr · Cited by 411
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
Motions or muscles? Some behavioral factors underlying robotic assistance of motor recovery
Hogan, N., Krebs, H. I., Rohrer, B., Palazzolo, J. J., Dipietro, L., Fasoli, S. E., Stein, J., Hughs, R., Frontera, W. R., Lynch, D., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0103 · Cited by 374
Cited by
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“This would exclude treadmill-based gait training orthoses such as the LOPES [19] and the Lokomat (Hocoma AG, Volketswil, Switzerland), which were among the classes of devices discussed in the review of Marchal-Crespo and Reinkensmeyer [20].”
Human-in-the-loop optimization of exoskeleton assistance during walking
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H. (2017) · Science · doi:10.1126/science.aal5054 · Cited by 1,011
Ham, R., Sugar, T., Vanderborght, B., Hollander, K., & Lefeber, D. (2009) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2009.933629 · Cited by 834
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Lower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
“Some exoskeletons are stationary, mounted above treadmills and used to provide gait retraining or rehabilitation for those with disabilities or injuries (Jezernik et al., 2003; Banala et al., 2007; Veneman et al., 2007).”
BackgroundCompliant actuation of rehabilitation robots
Vallery, H., Veneman, J., van Asseldonk, E., Ekkelenkamp, R., Buss, M., & van Der Kooij, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927689 · Cited by 448
Self-citationRehabilitation robots for the treatment of sensorimotor deficits: a neurophysiological perspective
Gassert, R., & Dietz, V. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0383-x · Cited by 440
Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2033061 · Cited by 421
Intention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Stronger, Smarter, Softer: Next-Generation Wearable Robots
Asbeck, A. T., De Rossi, S. M. M., Galiana, I., Ding, Y., & Walsh, C. J. (2014) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2360283 · Cited by 368
Bortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
Active Exoskeleton Control Systems: State of the Art
Anam, K., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.273 · Cited by 304
Assistive mobility devices focusing on Smart Walkers: Classification and review
Martins, M. M., Santos, C. P., Frizera-Neto, A., & Ceres, R. (2012) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2011.11.015 · Cited by 260
Towards more effective robotic gait training for stroke rehabilitation: a review
Pennycott, A., Wyss, D., Vallery, H., Klamroth-Marganska, V., & Riener, R. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-65 · Cited by 259
Robotic gait rehabilitation and substitution devices in neurological disorders: where are we now?
Calabrò, R. S., Cacciola, A., Bertè, F., Manuli, A., Leo, A., Bramanti, A., Naro, A., Milardi, D., & Bramanti, P. (2016) · Neurological Sciences · doi:10.1007/s10072-016-2474-4 · Cited by 259
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
A light-weight active orthosis for hip movement assistance
Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.015 · Cited by 258
Grimmer, M., Riener, R., Walsh, C. J., & Seyfarth, A. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0458-8 · Cited by 249
Biologically-inspired soft exosuit
Asbeck, A. T., Dyer, R. J., Larusson, A. F., & Walsh, C. J. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650455 · Cited by 240
Hesse, S., Waldner, A., & Tomelleri, C. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-30 · Cited by 225
Riener, R., Lünenburger, L., Maier, I. C., Colombo, G., & Dietz, V. (2010) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.1.2.197 · Cited by 223
“(USA), the “Lopes” by the University of Twente (Netherlands) [37] and the “ALEX” by the University of Delaware (USA) [38].”
BackgroundAdaptive Impedance Control of a Robotic Orthosis for Gait Rehabilitation
Hussain, S., Xie, S. Q., & Jamwal, P. K. (2013) · IEEE Transactions on Cybernetics · doi:10.1109/tsmcb.2012.2222374 · Cited by 223
“The developers of LOPES have tried to overcome the limitations of LOKOMAT and have used the concept of SEA for providing compliant-robot-assisted gait training [11].”
BackgroundMethodInfluentialWearable lower limb robotics: A review
Viteckova, S., Kutilek, P., & Jirina, M. (2013) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2013.03.005 · Cited by 221
“Beginning in 2001, a team at the University of Twente (Netherlands) developed a robotic device LOPES (LOwer extremity Powered ExoSkeleton) [47].”
BackgroundAdaptive Human–Robot Interaction Control for Robots Driven by Series Elastic Actuators
Li, X., Pan, Y., Chen, G., & Yu, H. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2626479 · Cited by 203
“…techniques for the human–robot interaction do not provide much flexibility for collaboration tasks, requiring that the robot leads or follows the human by assessing the performance of human in real time, e.g., the paradigm of “Assist-As-Needed (AAN)” [9], [26], [27] for robotic rehabilitation.”
BackgroundDevelopment of Active Lower Limb Robotic-Based Orthosis and Exoskeleton Devices: A Systematic Review
Kalita, B., Narayan, J., & Dwivedy, S. K. (2021) · International Journal of Social Robotics · doi:10.1007/s12369-020-00662-9 · Cited by 203
EMG and EPP-integrated human-machine interface between the paralyzed and rehabilitation exoskeleton
Yin, Y. H., Fan, Y. J., & Xu, L. D. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2178034 · Cited by 197
Extracting kinematic parameters for monkey bipedal walking from cortical neuronal ensemble activity
Fitzsimmons, N. A. (2009) · Frontiers in Integrative Neuroscience · doi:10.3389/neuro.07.003.2009 · Cited by 186
The Present and Future of Robotic Technology in Rehabilitation
Laut, J., Porfiri, M., & Raghavan, P. (2016) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-016-0139-0 · Cited by 179
“Similarly, LOPES is an eight degree-of-freedom exoskeleton device for the legs designed to actuate the leg for gait training or act passively as a measurement device [36].”
Hobbs, B., & Artemiadis, P. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00019 · Cited by 178
Murray, S. A., Ha, K. H., Hartigan, C., & Goldfarb, M. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2346193 · Cited by 177
“Despite the efficacy of the aforementioned control methods [12-17] in governing interaction between the patient and robot in robotically-assisted BWSTT systems, such methods are less well-suited to walking overground in an exoskeleton.”
MethodA Tutorial Survey and Comparison of Impedance Control on Robotic Manipulation
Song, P., Yu, Y., & Zhang, X. (2019) · Robotica · doi:10.1017/s0263574718001339 · Cited by 169
Veale, A. J., & Xie, S. Q. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.01.010 · Cited by 160
Cao, J., Xie, S. Q., Das, R., & Zhu, G. L. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.08.005 · Cited by 153
“Robot-in-charge, patient-in-charge and therapist-in-charge odes were implemented on LOPES gait training robot [82].”
MethodFusion of Multi-Sensor-Based Biomechanical Gait Analysis Using Vision and Wearable Sensor
Bijalwan, V., Semwal, V. B., & Mandal, T. K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3066473 · Cited by 122
Recognition of walking environments and gait period by surface electromyography
Kyeong, S., Shin, W., Yang, M., Heo, U., Feng, J.-R., & Kim, J. (2019) · Frontiers of Information Technology & Electronic Engineering · doi:10.1631/fitee.1800601 · Cited by 68
Design and control of a robotic lower extremity exoskeleton for gait rehabilitation
Unluhisarcikli, O., Pietrusinski, M., Weinberg, B., Bonato, P., & Mavroidis, C. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094973 · Cited by 66
“For example LOPES (University of Twente in the Netherlands) [9] uses Bowden-cable driven series elastic actuators.”
MethodOscillator-based walking assistance: A model-free approach
Ronsse, R., Koopman, B., Vitiello, N., Lenzi, T., De Rossi, S. M. M., van den Kieboom, J., van Asseldonk, E., Carrozza, M. C., van der Kooij, H., & Ijspeert, A. J. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975352 · Cited by 50
“3), a treadmill-based lower-limb exoskeleton developed at the University of Twente [9], [19]–[21], and capable of assisting 8 DOFs of the lower-limbs (right and left hip abduction/adduction, hip flexion/extension, and knee flexion/extension, forward/backward and sideways movements of the pelvis) by providing torques t…”
BackgroundMethod
Metadata
- Authors
- Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2007-09
- Volume
- 15
- Issue
- 3
- Pages
- 379-386
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2166869394
- Cited by
- 1,280
- References
- 24
- FWCI
- 15.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.