A Robot and Control Algorithm That Can Synchronously Assist in Naturalistic Motion During Body-Weight-Supported Gait Training Following Neurologic Injury
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Locomotor training using body weight support on a treadmill and manual assistance is a promising rehabilitation technique following neurological injuries, such as spinal cord injury (SCI) and stroke. Previous robots that automate this technique impose constraints on naturalistic walking due to their kinematic structure, and are typically operated in a stiff mode, limiting the ability of the patient or human trainer to influence the stepping pattern. We developed a pneumatic gait training robot that allows for a full range of natural motion of the legs and pelvis during treadmill walking, and provides compliant assistance. However, we observed an unexpected consequence of the device's compliance: unimpaired and SCI individuals invariably began walking out-of-phase with the device. Thus, the robot perturbed rather than assisted stepping. To address this problem, we developed a novel algorithm that synchronizes the device in real-time to the actual motion of the individual by sensing the state error and adjusting the replay timing to reduce this error. This paper describes data from experiments with individuals with SCI that demonstrate the effectiveness of the synchronization algorithm, and the potential of the device for relieving the trainers of strenuous work while maintaining naturalistic stepping.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729 · cited 1×
“The Lokomat research group has also recently addressed the potential problem of rigid assistance by implementing impedance control that relies on sensing interaction force between the patient and the device, making it possible to provide compliant assistance to the legs [14], [15].”
BackgroundVisintin, M., Barbeau, H., Korner-Bitensky, N., & Mayo, N. E. (1998) · Stroke · doi:10.1161/01.str.29.6.1122 · Cited by 688
Human Lumbosacral Spinal Cord Interprets Loading During Stepping
Harkema, S. J., Hurley, S. L., Patel, U. K., Requejo, P. S., Dobkin, B. H., & Edgerton, V. R. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.2.797 · Cited by 606
Self-citationLocomotor Training After Human Spinal Cord Injury: A Series of Case Studies
Behrman, A. L., & Harkema, S. J. (2000) · Physical Therapy · doi:10.1093/ptj/80.7.688 · Cited by 593 · cited 1×
“In fact, during a typical BWS gait training session, a trainer assists the pelvic motion to promote proper weight shift and leg swing, while maintaining balance and stability [5].”
BackgroundSelf-citationRobotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503 · cited 1×
“The Lokomat is a motorized exoskeleton that can drive hip and knee flexion through the four rotary joints driven by dc motors via precision ball screws [9].”
BackgroundIncreasing productivity and quality of care: robot-aided neuro-rehabilitation.
Krebs, H. I., Volpe, B. T., Aisen, M. L., & Hogan, N. (2000) · PubMed · Cited by 441
Locomotor activity in spinal man
Dietz, V, Colombo, G., & Jensen, L. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90751-x · Cited by 395
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Retraining the injured spinal cord
Edgerton, V. R., de Leon, R. D., Harkema, S. J., Hodgson, J. A., London, N., Reinkensmeyer, D. J., Roy, R. R., Talmadge, R. J., Tillakaratne, N. J., Timoszyk, W., et al. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0015b.x · Cited by 382 · cited 1×
“LOCOMOTOR training using body weight support on a treadmill (BWST) and manual assistance of the legs and the pelvis is an emerging technique for gait rehabilitation following neurological injuries, such as spinal cord injury (SCI) and stroke, that has shown promising results [1]–[6].”
MethodSelf-citationAutomatic Gait-Pattern Adaptation Algorithms for Rehabilitation With a 4-DOF Robotic Orthosis
Jezernik, S., Colombo, G., & Morari, M. (2004) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2004.825515 · Cited by 312 · cited 1×
“The Lokomat research group has also recently addressed the potential problem of rigid assistance by implementing impedance control that relies on sensing interaction force between the patient and the device, making it possible to provide compliant assistance to the legs [14], [15].”
BackgroundAlterations in muscle activation patterns during robotic-assisted walking
Hidler, J. M., & Wall, A. E. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.09.016 · Cited by 309 · cited 1×
“As a result of such kinematic constraints, the dynamics experienced by the patient can be substantially different from that of an actual gait [11].”
BackgroundTreadmill walking with partial body weight support versus floor walking in hemiparetic subjects
Hesse, S., Konrad, M., & Uhlenbrock, D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90279-4 · Cited by 305
HapticWalker---a novel haptic foot device
Schmidt, H., Hesse, S., Bernhardt, R., & Krüger, J. (2005) · ACM Transactions on Applied Perception · doi:10.1145/1060581.1060589 · Cited by 200 · cited 1×
“Likewise, the MGT group has designed a device (the “Haptic Walker”) with more DOF that relies on force feedback to accommodate more natural motion of the legs [16], [17].”
MethodA mechanized gait trainer for restoring gait in nonambulatory subjects
Hesse, S., Uhlenbrock, D., Werner, C., & Bardeleben, A. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2000.6280 · Cited by 193
Baker, R. (2001) · Gait & Posture · doi:10.1016/s0966-6362(00)00083-7 · Cited by 160
Laufband (Treadmill) Therapy in Incomplete Paraplegia and Tetraplegia
WERNIG, A., NANASSY, A., & MÜLLER, S. (1999) · Journal of Neurotrauma · doi:10.1089/neu.1999.16.719 · Cited by 160
A robotic device for manipulating human stepping
Emken, J. L., Wynne, J. H., Harkema, S. J., & Reinkensmeyer, D. J. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2005.861481 · Cited by 62 · cited 1×
“The ambulation-assisting robotic tool for human rehabilitation (ARTHuR) achieves backdrivability and force control capability with a two bar linkage mechanism and two linear motors, and can measure and manipulate the motion of either the ankle or the knee during stepping on a treadmill [13].”
MethodSelf-citationAn Assistive Robotic Device That Can Synchronize to the Pelvic Motion During Human Gait Training
Aoyagi, D., Ichinose, W. E., Harkema, S. J., Reinkensmeyer, D. J., & Bobrow, J. E. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1502026 · Cited by 56 · cited 2×
“timing information obtained from footswitches [19].”
MethodSelf-citationA robotic device for measuring and controlling pelvic motion during locomotor rehabilitation
Ichinose, W. E., Reinkensmeyer, D. J., Aoyagi, D., Lin, J. T., Ngai, K., Edgerton, V. R., Harkema, S. J., & Bobrow, J. E. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279715 · Cited by 48 · cited 3×
“We refer the reader to [18], [21], and [22] for more details.”
BackgroundSelf-citationHuman Step Rehabilitation Using a Robot Attached to the Pelvis
Aoyagi, D., Inchinose, W. E., Reinkensmeyer, D. J., & Bobrow, J. E. (2004) · doi:10.1115/imece2004-59472 · Cited by 17 · cited 2×
“We refer the reader to [18], [21], and [22] for more details.”
BackgroundSelf-citation
Cited by
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Self-citationOptimizing Compliant, Model-Based Robotic Assistance to Promote Neurorehabilitation
Wolbrecht, E. T., Chan, V., Reinkensmeyer, D. J., & Bobrow, J. E. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918389 · Cited by 506
Self-citationCompliant actuation of rehabilitation robots
Vallery, H., Veneman, J., van Asseldonk, E., Ekkelenkamp, R., Buss, M., & van Der Kooij, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927689 · Cited by 448
Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2033061 · Cited by 421
Bortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
Metadata
- Authors
- Aoyagi, D., Ichinose, W. E., Harkema, S. J., Reinkensmeyer, D. J., & Bobrow, J. E.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2007-09
- Volume
- 15
- Issue
- 3
- Pages
- 387-400
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2047688129
- Cited by
- 249
- References
- 21
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.