Evaluation of Head Orientation and Neck Muscle EMG Signals as Command Inputs to a Human–Computer Interface for Individuals With High Tetraplegia
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We investigated the performance of three user interfaces for restoration of cursor control in individuals with tetraplegia: head orientation, electromyography (EMG) from face and neck muscles, and a standard computer mouse (for comparison). Subjects engaged in a 2-D, center-out, Fitts' Law style task and performance was evaluated using several measures. Overall, head orientation commanded motion resembled mouse commanded cursor motion (smooth, accurate movements to all targets), although with somewhat lower performance. EMG commanded movements exhibited a higher average speed, but other performance measures were lower, particularly for diagonal targets. Compared to head orientation, EMG as a cursor command source was less accurate, was more affected by target direction and was more prone to overshoot the target. In particular, EMG commands for diagonal targets were more sequential, moving first in one direction and then the other rather than moving simultaneous in the two directions. While the relative performance of each user interface differs, each has specific advantages depending on the application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01338.x · Cited by 88,486
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
The information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466 · cited 1×
“Fitts first quantified human motor performance in 1954 in his seminal paper describing the limits of human speed and accuracy in a one degree-of-freedom tapping task [16].”
BackgroundThe information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1992) · Journal of Experimental Psychology: General · doi:10.1037/0096-3445.121.3.262 · Cited by 6,278
Soukoreff, R. W., & MacKenzie, I. S. (2004) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2004.09.001 · Cited by 1,064 · cited 7×
“to the previous two mentioned command sources and to serve as a comparison to similar studies [22], [23].”
BackgroundMethodResultInfluentialCARD, S. K., ENGLISH, W. K., & BURR, B. J. (1978) · Ergonomics · doi:10.1080/00140137808931762 · Cited by 887 · cited 5×
“In 1978, Card demonstrated that human commanded cursor motion follows a Fitts’ Law model [21], initiating the field 1534-4320/$25.00 © 2008 IEEE of human–computer interface evaluation.”
BackgroundMethodInfluentialAccuracy measures for evaluating computer pointing devices
MacKenzie, I. S., Kauppinen, T., & Silfverberg, M. (2001) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/365024.365028 · Cited by 448 · cited 4×
“to the previous two mentioned command sources and to serve as a comparison to similar studies [22], [23].”
BackgroundMethodResultInfluentialAn Inductive Tongue Computer Interface for Control of Computers and Assistive Devices
Struijk, L. N. S. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880871 · Cited by 180 · cited 1×
“These interfaces have been based on mouthsticks [5], chin operated devices [6], voice commands [7], tongue manipulated devices [5], [8], and head position [9], [10].”
Fitts’ Law in Two Dimensions with Hand and Head Movements Movements
Jagacinski, R. J., & Monk, D. L. (1985) · Journal of Motor Behavior · doi:10.1080/00222895.1985.10735338 · Cited by 180 · cited 9×
“The directional effects seen in head orientation commanded cursor velocity and target acquisition match those in similar studies that compared head orientation commanded cursor position to joystick performance [24], [25], [27].”
BackgroundMethodResultInfluentialControlling mouse pointer position using an infrared head-operated joystick
Evans, D. G., Drew, R., & Blenkhorn, P. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.830955 · Cited by 164 · cited 1×
“stick-like” velocity control was employed as it has been found in previous studies to be preferred by subjects because it requires less absolute accuracy and was less fatiguing [29].”
Method
Cited by
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269
Jaramillo-Yánez, A., Benalcázar, M. E., & Mena-Maldonado, E. (2020) · Sensors · doi:10.3390/s20092467 · Cited by 259
Simon, A. M., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0149 · Cited by 226
“We calculated path efficiency as the shortest path to the target divided by the total distance traveled by the virtual hand [24].”
MethodIson, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“More quantitative measures are proposed in other works, defining throughput, overshoot, average speed, and direction ratio as useful indicators of real-time performance [274, 275].”
BackgroundIs Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?
Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287383 · Cited by 218
“It is important to note that, even though the definitions of TP and in the current study are similar to those in [23], the optimal path considered here was not the straight line from the starting point to the target point, as the control variables were the angles in the two DoFs and not in the Cartesian coordinates as…”
Functional Electrical Stimulation and Spinal Cord Injury
Ho, C. H., Triolo, R. J., Elias, A. L., Kilgore, K. L., DiMarco, A. F., Bogie, K., Vette, A. H., Audu, M. L., Kobetic, R., Chang, S. R., et al. (2014) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2014.05.001 · Cited by 203
“Finally, high-frequency (kilohertz) stimulation can provide temporary, reversible, and complete conduction block of the pudendal nerve, and thus stop reflexive EUS contractions, allowing bladder voiding equivalent to nerve transection.83 Bilateral pudendal nerve block can provide clinical daily voiding of awake animal…”
BackgroundInfluentialSupport Vector Regression for Improved Real-Time, Simultaneous Myoelectric Control
Ameri, A., Kamavuako, E. N., Scheme, E. J., Englehart, K. B., & Parker, P. A. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2323576 · Cited by 171
Regression convolutional neural network for improved simultaneous EMG control
Ameri, A., Akhaee, M. A., Scheme, E., & Englehart, K. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0e2e · Cited by 170
“The control performance was evaluated using four metrics [45] of completion rate, throughput, overshoot, and path efficiency.”
MethodImplanted Neuroprosthesis for Restoring Arm and Hand Function in People With High Level Tetraplegia
Memberg, W. D., Polasek, K. H., Hart, R. L., Bryden, A. M., Kilgore, K. L., Nemunaitis, G. A., Hoyen, H. A., Keith, M. W., & Kirsch, R. F. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.01.028 · Cited by 137
Self-citationRupp, R., Rohm, M., Schneiders, M., Kreilinger, A., & Muller-Putz, G. R. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2395253 · Cited by 84
“[88] M.”
BackgroundA Wireless Magnetoresistive Sensing System for an Intraoral Tongue-Computer Interface
Park, H., Kiani, M., Lee, H.-M., Kim, J., Block, J., Gosselin, B., & Ghovanloo, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2227962 · Cited by 79
Use of probabilistic weights to enhance linear regression myoelectric control
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066030 · Cited by 15
Metadata
- Authors
- Williams, M. R., & Kirsch, R. F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2008-10
- Volume
- 16
- Issue
- 5
- Pages
- 485-496
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2150663134
- Cited by
- 189
- References
- 24
- FWCI
- 9.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.