Adaptive Pattern Recognition of Myoelectric Signals: Exploration of Conceptual Framework and Practical Algorithms
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Pattern recognition is a useful tool for deciphering movement intent from myoelectric signals. Recognition paradigms must adapt with the user in order to be clinically viable over time. Most existing paradigms are static, although two forms of adaptation have received limited attention. Supervised adaptation can achieve high accuracy since the intended class is known, but at the cost of repeated cumbersome training sessions. Unsupervised adaptation attempts to achieve high accuracy without knowledge of the intended class, thus achieving adaptation that is not cumbersome to the user, but at the cost of reduced accuracy. This study reports a novel adaptive experiment on eight subjects that allowed repeated measures post-hoc comparison of four supervised and three unsupervised adaptation paradigms. All supervised adaptation paradigms reduced error over time by at least 26% compared to the nonadapting classifier. Most unsupervised adaptation paradigms provided smaller reductions in error, due to frequent uncertainty of the correct class. One method that selected high-confidence samples showed the most practical implementation, although the other methods warrant future investigation. Supervised adaptation should be considered for incorporation into any clinically viable pattern recognition controller, and unsupervised adaptation should receive renewed interest in order to provide transparent adaptation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“2023282 logic [5], [9]–[11], neural networks [2], [3], [12]–[16], and”
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“The Neural Engineering Center for Artificial Limbs performs research on subjects with targeted muscle reinnervation (TMR)—a novel surgical technique that provides the residual muscles of amputees with similar signal content to the normal muscles of able-bodied subjects [25]‐[ 29 ].”
BackgroundSelf-citationA wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 1×
“A wide range of feature sets, including time-domain [1]‐[7] and frequency domain [ 8 ], combined with a wide range of classifiers, including fuzzy”
BackgroundHuang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643 · cited 3×
“logic [5], [9]‐[11], neural networks [2], [3], [12]‐[ 16 ], and Bayesian statistics [16]‐[18], have yielded low classification error (error) on able-bodied subjects.”
BackgroundInfluentialControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606 · cited 1×
“Although these studies report low error in a single session, robustness over time or during different activities has rarely been evaluated [ 20 ].”
BackgroundKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Self-citationControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518 · cited 2×
“Several studies have produced low error on subjects with an amputation [9], [13], [14], [16], [17], [ 19 ].”
BackgroundResultA human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483 · cited 4×
“Similar to Fukuda’s algorithm [13], UH adaptation tagged classifications that had high confidence (low entropy) and added these samples to recalculate the classifier boundaries.”
BackgroundMethodInfluentialKuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482 · cited 2×
“The Neural Engineering Center for Artificial Limbs performs research on subjects with targeted muscle reinnervation (TMR)—a novel surgical technique that provides the residual muscles of amputees with similar signal content to the normal muscles of able-bodied subjects [ 25 ]‐[29].”
BackgroundSelf-citationA heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control
Ajiboye, A. B., & Weir, R. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847357 · Cited by 415 · cited 2×
“2023282 logic [5], [9]–[11], neural networks [2], [3], [12]–[16], and”
BackgroundFuzzy EMG classification for prosthesis control
Chan, F. H. Y., Yang, Y.-S., Lam, F. K., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867872 · Cited by 376
Neuro-Fuzzy Control of a Robotic Exoskeleton With EMG Signals
Kiguchi, K., Tanaka, T., & Fukuda, T. (2004) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2004.832525 · Cited by 364 · cited 1×
“2023282 logic [5], [9]–[11], neural networks [2], [3], [12]–[16], and”
Chu, J.-U., Moon, I., & Mun, M.-S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883695 · Cited by 352 · cited 1×
“Several studies have produced low error on subjects with an amputation [9], [13], [14], [16], [ 17 ], [19].”
BackgroundHargrove, L., Englehart, K., & Hudgins, B. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.005 · Cited by 276 · cited 3×
“In this study and similar work [ 23 ], the concept is extended to denote a representative feature set that corresponds to the optimal location of the cluster, rather than the mean center of the cluster.”
BackgroundMethodInfluentialMyoelectric teleoperation of a complex robotic hand
Farry, K. A., Walker, I. D., & Baraniuk, R. G. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.538982 · Cited by 248
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Self-citationGraupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205 · cited 1×
“logic [5], [9]‐[11], neural networks [2], [ 3 ], [12]‐[16], and Bayesian statistics [16]‐[18], have yielded low classification error (error) on able-bodied subjects.”
BackgroundEMG pattern recognition based on artificial intelligence techniques
Park, S.-H., & Lee, S.-P. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736154 · Cited by 197 · cited 1×
“logic [ 5 ], [9]‐[11], neural networks [2], [3], [12]‐[16], and Bayesian statistics [16]‐[18], have yielded low classification error (error) on able-bodied subjects.”
BackgroundHuang, H., Zhou, P., Li, G., & Kuiken, T. A. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.910282 · Cited by 187
Self-citationBlind Separation of Linear Instantaneous Mixtures of Nonstationary Surface Myoelectric Signals
Farina, D., Févotte, C., Doncarli, C., & Merletti, R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.828048 · Cited by 102 · cited 1×
“Bayesian statistics [16]–[18], have yielded low classification”
Mézard, M. (2007) · Science · doi:10.1126/science.1139678 · Cited by 69
Huang, H., Liu, Y., Liu, L.-W., & Wong, C.-S. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2003.1241803 · Cited by 67
EMG-Based Motion Discrimination Using a Novel Recurrent Neural Network
Bu, N., Fukuda, O., & Tsuji, T. (2003) · Journal of Intelligent Information Systems · doi:10.1023/a:1024706431807 · Cited by 56 · cited 7×
“Related work by Bu and Fukuda [12] achieved similar results (94% accuracy) using a recurrent log-linearized Gaussian mixture model, while reporting lower accuracy (89”
ResultInfluentialFatigue Estimation With a Multivariable Myoelectric Mapping Function
MacIsaac, D., Parker, P. A., Englehart, K. B., & Rogers, D. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870220 · Cited by 55
Feature-based classification of myoelectric signals using artificial neural networks
Gallant, P. J., Morin, E. L., & Peppard, L. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523219 · Cited by 52 · cited 1×
“Several studies have produced low error on subjects with an amputation [9], [13], [ 14 ], [16], [17], [19].”
BackgroundOn-line Learning Based Electromyogram to Forearm Motion Classifier with Motor Skill Evaluation.
NISHIKAWA, D., Yu, W., Maruishi, M., Watanabe, I., Yokoi, H., Mano, Y., & Kakazu, Y. (2000) · JSME International Journal Series C · doi:10.1299/jsmec.43.906 · Cited by 43 · cited 3×
“changes can increase error [21]–[23], the influence of displace-”
BackgroundResultInfluentialOn automatic identification of upper-limb movements using small-sized training sets of EMG signals
Micera, S., Sabatini, A. M., & Dario, P. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00069-2 · Cited by 40
Myoelectric signal analysis using neural networks
Kelly, M. F., Parker, P. A., & Scott, R. N. (1990) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.62909 · Cited by 21 · cited 1×
“ture sets, including time-domain [1]–[7] and frequency domain”
Background
Research works printed but not linked: 1
- 10.1109/ROMAN.2006.314455 · doi:10.1109/roman.2006.314455
Cited by
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Study of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582
Self-citationMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Zhai, X., Jelfs, B., Chan, R. H. M., & Tin, C. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00379 · Cited by 357
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citation
Metadata
- Authors
- Sensinger, J. W., Lock, B. A., & Kuiken, T. A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-06
- Volume
- 17
- Issue
- 3
- Pages
- 270-278
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2156394514
- Cited by
- 239
- References
- 30
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.