Pathological Tremor and Voluntary Motion Modeling and Online Estimation for Active Compensation
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
This paper presents an algorithm to perform online tremor characterization from motion sensors measurements, while filtering the voluntary motion performed by the patient. In order to estimate simultaneously both nonstationary signals in a stochastic filtering framework, pathological tremor was represented by a time-varying harmonic model and voluntary motion was modeled as an auto-regressive moving-average (ARMA) model. Since it is a nonlinear problem, an extended Kalman filter (EKF) was used. The developed solution was evaluated with simulated signals and experimental data from patients with different pathologies. Also, the results were comprehensively compared with alternative techniques proposed in the literature, evidencing the better performance of the proposed method. The algorithm presented in this paper may be an important tool in the design of active tremor compensation systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Optimal State Estimation: Kalman, H∞, and Nonlinear Approaches
Simon, D. (2006) · doi:10.1002/0470045345 · Cited by 4,875
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 6×
“In some works, such as [ 6 ], a cutoff frequency of 2 Hz was chosen.”
BackgroundMethodInfluentialClinically deployable Kinesia™ technology for automated tremor assessment
Giuffrida, J. P., Riley, D. E., Maddux, B. N., & Heldman, D. A. (2009) · Movement Disorders · doi:10.1002/mds.22445 · Cited by 251
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 1×
“Likewise, these online methods are a fundamental part in active devices designed to directly attenuate tremor, such as orthosis [6] or solutions based on electrical stimulation [ 7 ].”
Method(2006) · doi:10.1007/978-1-84628-056-6 · Cited by 139
A Review on Techniques for Tremor Recording and Quantification
Mansur, P. H. G., Cury, L. K. P., Andrade, A. O., Pereira, A. A., Miotto, G. A. A., Soares, A. B., & Naves, E. L. M. (2007) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v35.i5.10 · Cited by 100
Spyers-Ashby, J. M., Bain, P. G., & Roberts, S. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00064-8 · Cited by 92
Adaptive Fourier modeling for quantification of tremor
Riviere, C. N., Reich, S. G., & Thakor, N. V. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02263-2 · Cited by 83
Bandlimited Multiple Fourier Linear Combiner for Real-time Tremor Compensation
Veluvolu, K. C., Tan, U. X., Latt, W. T., Shee, C. Y., & Ang, W. T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352922 · Cited by 83
Modeling Noisy Time Series: Physiological Tremor
Timmer, J. (1998) · International Journal of Bifurcation and Chaos · doi:10.1142/s0218127498001157 · Cited by 73
Research works printed but not linked: 3
- b, 2008, Online pathological tremor characterization with Kalman filtering, Proc 30th Annu Int Conf IEEE Eng Med Biol Soc, 1753
- rocon, 2006, Reduccin activa de temblor patolgico de miembro superior mediante exoesqueletos robticos
- elble, 1990, Tremor
Cited by
Tatinati, S., Veluvolu, K. C., & Ang, W. T. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2014.2381495 · Cited by 77
A Novel Setup and Protocol to Measure the Range of Motion of the Wrist and the Hand
Nizamis, K., Rijken, N. H. M., Mendes, A., et al. (2018) · Sensors · doi:10.3390/s18103230 · Cited by 62
Parkinson's Disease Motor Symptoms in Machine Learning: A Review
Ahlrichs, C., & Lawo, M. (2013) · Health Informatics - An International Journal · doi:10.5121/hiij.2013.2401 · Cited by 57
Multistep Prediction of Physiological Tremor for Surgical Robotics Applications
Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264546 · Cited by 51
A Multimodal Human–Robot Interface to Drive a Neuroprosthesis for Tremor Management
Gallego, J. Á., Ibanez, J., Dideriksen, J. L., Serrano, J. I., del Castillo, M. D., Farina, D., & Rocon, E. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) · doi:10.1109/tsmcc.2012.2200101 · Cited by 46
Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859793 · Cited by 42
On the Use of Fixed‐Intensity Functional Electrical Stimulation for Attenuating Essential Tremor
Bó, A. P. L., Azevedo‐Coste, C., Geny, C., Poignet, P., & Fattal, C. (2014) · Artificial Organs · doi:10.1111/aor.12261 · Cited by 40
Self-citationTatinati, S., Veluvolu, K. C., Hong, S.-M., Latt, W. T., & Ang, W. T. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2271737 · Cited by 38
Shahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
“Such technologies 40,42,45,46 are mainly developed to remove (damp out or compensate) the tremor and assist patients in performing their voluntary movements 41,47–49 .”
BackgroundDesign and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
Zhou, Y., Ibrahim, A. H., Hardy, K. G., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3080622 · Cited by 37
Repetitive control of functional electrical stimulation for induced tremor suppression
Freeman, C. T., Sampson, P., Burridge, J. H., & Hughes, A.-M. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.10.008 · Cited by 31
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.10.007 · Cited by 29
Liu, Z., Mao, C., Luo, J., Zhang, Y., & Chen, C. L. P. (2014) · Knowledge-Based Systems · doi:10.1016/j.knosys.2014.03.025 · Cited by 32
Muscle Fatigue Induced Hand Tremor Clustering in Dynamic Laparoscopic Manipulation
Chandra, S., Hayashibe, M., & Thondiyath, A. (2018) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2018.2882957 · Cited by 25
Liu, Z., Luo, J., Wang, L., Zhang, Y., Chen, C. L. P., & Chen, X. (2013) · International Journal of Systems Science · doi:10.1080/00207721.2013.821718 · Cited by 26
IMU Motion Capture Method with Adaptive Tremor Attenuation in Teleoperation Robot System
Zhu, H., Li, X., Wang, L., Chen, Z., Shi, Y., Zheng, S., & Li, M. (2022) · Sensors · doi:10.3390/s22093353 · Cited by 26
Three-domain fuzzy wavelet broad learning system for tremor estimation
Lin, J., Liu, Z., Chen, C. L. P., & Zhang, Y. (2019) · Knowledge-Based Systems · doi:10.1016/j.knosys.2019.105295 · Cited by 25
Development of a closed-loop system for tremor suppression in patients with Parkinson's disease
Xu, F. L., Hao, M. Z., Xu, S. Q., Hu, Z. X., Xiao, Q., & Lan, N. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591063 · Cited by 18
HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2894005 · Cited by 17
Lambrecht, S., Gallego, J. A., Rocon, E., & Pons, J. L. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00221 · Cited by 16
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592069 · Cited by 16
Hilbert–Huang transform based instrumental assessment of intention tremor in multiple sclerosis
Carpinella, I., Cattaneo, D., & Ferrarin, M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046011 · Cited by 12
Prediction of pathological tremor using adaptive multiple oscillators linear combiner
Xiao, F., Gao, Y., Wang, S., & Zhao, J. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.01.006 · Cited by 11
Multibody Analysis and Control of a Full-Wrist Exoskeleton for Tremor Alleviation
Wang, J., & Barry, O. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047424 · Cited by 9
Comparative Assessment of a Novel Optical Human-Machine Interface for Laparoscopic Telesurgery
Despinoy, F., Sánchez, A., Zemiti, N., Jannin, P., & Poignet, P. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-07521-1_3 · Cited by 10
Self-citationTracking and Classification of Head Movement for Augmentative and Alternative Communication Systems
(2022) · doi:10.3390/s22020435 · Cited by 9
Self-citationOn the use of FES to attenuate tremor by modulating joint impedance
Bó, A. P. L., Coste, C., Poignet, P., Gény, C., & Fattal, C. (2011) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2011.6161352 · Cited by 9
Self-citationExploring data-driven modeling and analysis of nonlinear pathological tremors
Wang, J., & Barry, O. (2021) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.107659 · Cited by 8
Involuntary movement during haptics-enabled robotic rehabilitation: Analysis and control design
Atashzar, S. F., Saxena, A., Shahbazi, M., & Patel, R. V. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6943060 · Cited by 7
Dynamic estimation strategy for E-BMFLC filters in analyzing pathological hand tremors
Ghassab, V. K., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2017) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2017.8308681 · Cited by 8
Wang, J., & Barry, O. R. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3111878 · Cited by 3
Online learning for vibration suppression in physical robot interaction using power tools
Solak, G., & Ajoudani, A. (2026) · Autonomous Robots · doi:10.1007/s10514-026-10252-9 · Cited by 4
Assessment and Elimination of Surgeon Hand Tremor During Robotic Surgery
Kumar, A., Kumar, S., & Kumar, A. (2023) · Springer eBooks · doi:10.1007/978-981-99-2074-7_97 · Cited by 3
Xue, X., Iyer, A., Roque, D., & Sharma, N. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123909 · Cited by 3
Ultrasound-Enhanced Data-Driven Modeling for Characterizing Natural Wrist Tremor Dynamics
Xue, X., Ganesh, V., Iyer, A., Roque, D., Jiang, X., & Sharma, N. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3622539 · Cited by 2
Assessment and Elimination of Surgeon Hand Tremor During Robotic Surgery
Kumar, A., Kumar, S., & Kumar, A. (2022) · Springer eBooks · doi:10.1007/978-981-19-1550-5_97-1 · Cited by 4
MODEL OF AN ADAPTIVE ENERGY HARVESTER WITH ELECTRO-RHEOLOGICAL FLUID
Teodorescu, H.-N. (2015) · Cited by 1
Bó, A. P. L. (2010) · theses.fr (ABES) · doi:10.70675/c65c8f82zcd5fz4e12z9e9cz6a38ef9757cf · Cited by 5
Self-citationONLINE CYCLIC MOTION MODELING AND FEEDBACK FOR PHYSICAL TRAINING AND REHABILITATION
(2014) · Cited by 1
Self-citationXiang, Q. Z. (2011) · theses.fr (ABES) · doi:10.70675/5efc8258ze340z47c1z9c47z99959f646278 · Cited by 2
Local Circular Modeling based Real-time Pathological Tremor Characterization for FES Applications
Tatinati, S., Wang, Y., Veluvolu, K. C., & Ang, W. T. (2015) · International Convention on Rehabilitation Engineering & Assistive Technology
Statistical learning modeling for tremor signal based on empirical mode decomposition method
Zhong, S. S., & Huang, X. (2015) · IEEE International Conference on Software Engineering and Service Science (ICSESS) · doi:10.1109/icsess.2015.7339212
Towards the Development of a Wearable Tremor Suppression Glove
Zhou, Y. (2015) · Scholarship@Western (Western University)
- Self-citation
Multiple-Model and Reduced-Order Kalman Filtering for Pathological Hand Tremor Extraction
Ghassab, V. K., Mohammadi, A., Atashzar, S. F., & Patel, R. V. (2018) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2018.8462491
Metadata
- Authors
- Bo, A. P. L., Poignet, P., & Geny, C.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- ORCID
- Poignet, Philippe
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-04
- Volume
- 19
- Issue
- 2
- Pages
- 177-185
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2132176043
- Cited by
- 53
- References
- 13
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 2 · 2019: 2 · 2018: 5 · 2017: 1 · 2016: 4 · 2015: 7 · 2014: 8 · 2013: 10 · 2012: 1
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
- Keywords
- pathological tremor, online estimation, ARMA models, extended Kalman filter, motion sensors, tremor filtering
- MeSH terms
- Algorithms, Computer Simulation, Female, Hand, Humans, Male, Models, Neurological, Motion, Motor Skills, Psychomotor Performance, Tremor, Normal Distribution, Linear Models, Nonlinear Dynamics, Dyskinesias
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.