Abstract

This work assesses the ability of transradial amputees to discriminate multi-site tactile stimuli in sensory discrimination tasks. It compares different sensory feedback modalities using an artificial hand prosthesis in: 1) a modality matched paradigm where pressure recorded on the five fingertips of the hand was fed back as pressure stimulation on five target points on the residual limb; and 2) a modality mismatched paradigm where the pressures were transformed into mechanical vibrations and fed back. Eight transradial amputees took part in the study and were divided in two groups based on the integrity of their phantom map; group A had a complete phantom map on the residual limb whereas group B had an incomplete or nonexisting map. The ability in localizing stimuli was compared with that of 10 healthy subjects using the vibration feedback and 11 healthy subjects using the pressure feedback (in a previous study), on their forearms, in similar experiments. Results demonstrate that pressure stimulation surpassed vibrotactile stimulation in multi-site sensory feedback discrimination. Furthermore, we demonstrate that subjects with a detailed phantom map had the best discrimination performance and even surpassed healthy participants for both feedback paradigms whereas group B had the worst performance overall. Finally, we show that placement of feedback devices on a complete phantom map improves multi-site sensory feedback discrimination, independently of the feedback modality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2012.2217989

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 33

  1. 10.1016/j.neuroscience.2008.07.053 · DOI
  2. 10.3758/BF03194834 · DOI · Paper page
  3. 10.3109/02844310903113107 · DOI
  4. 10.1109/TBME.2011.2173342 · DOI · Paper page
  5. 10.1186/1475-925X-9-50 · DOI
  6. weinstein, 1968, Intensive and extensive aspects of tactile sensitivity as a function of body part, sex, and laterality. The skin senses, The Skin Senses, 195
  7. 10.1152/jn.00483.2005 · DOI · Paper page
  8. talbot, 1968, The sense of flutter-vibration: comparison of the human capability with response patterns of mechanoreceptive afferents from the monkey hand, J Neurophysiol, 31, 301, 10.1152/jn.1968.31.2.301 · DOI · Paper page
  9. 10.3109/02844310903259090 · DOI
  10. weber, 1978, The Sense of Touch
  11. 10.1007/BF02478841 · DOI
  12. 10.1007/BF02477743 · DOI
  13. 10.1007/BF02440956 · DOI
  14. arieta, 2005, Study on the effects of electrical stimulation on the pattern recognition for an EMG prosthetic application, Proc IEEE Eng Med Biol Soc Conf, 7, 6919
  15. 10.1186/1743-0003-8-9 · DOI
  16. 10.1007/BF02478123 · DOI
  17. 10.1109/TRO.2007.910708 · DOI · Paper page
  18. 10.1109/TNSRE.2011.2170856 · DOI
  19. 10.1186/1743-0003-8-60 · DOI · Paper page
  20. 10.1073/pnas.90.22.10413 · DOI · Paper page
  21. ehrsson, 2004, That's my hand! activity in premotor cortex reflects feeling of ownership of a limb, Science, 305, 875, 10.1126/science.1097011 · DOI · Paper page
  22. 10.1097/00001756-199804200-00011 · DOI · Paper page
  23. 10.1007/BF00227253 · DOI · Paper page
  24. 10.3109/03091908809030173 · DOI · Paper page
  25. 10.1093/brain/awn297 · DOI · Paper page
  26. sacks, 1998, A Leg to Stand On
  27. 10.1007/BF00229422 · DOI · Paper page
  28. 10.1109/10.68204 · DOI · Paper page
  29. ehrsson, 2000, Cortical activity in precision-versus power-grip tasks: An fMRI study, J Neurophysiol, 83, 528, 10.1152/jn.2000.83.1.528 · DOI · Paper page
  30. antfolk, 0, Transfer of tactile input from an artificial hand to the forearm: Experiments in amputees and healthy volunteers, Disabil Rehabil Assist Technol
  31. 10.1073/pnas.0706525104 · DOI · Paper page
  32. 10.1186/1743-0003-8-29 · DOI · Paper page
  33. 10.1115/1.4004653 · DOI

Cited by

See all 194

Metadata

Authors
Antfolk, C., D'Alonzo, M., Controzzi, M., Lundborg, G., Rosen, B., Sebelius, F., & Cipriani, C.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2013-01
Volume
21
Issue
1
Pages
112-120
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2017326126
Cited by
194
References
5
FWCI
5.22
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Redirection of Sensation From Prosthetic Fingers to the Phantom Hand Map on Transradial Amputees: Vibrotactile Versus Mechanotactile Sensory Feedback. https://app.cochat.ai/papers/10.1109/tnsre.2012.2217989
The paper
Antfolk, C., D'Alonzo, M., Controzzi, M., Lundborg, G., Rosen, B., Sebelius, F., & Cipriani, C. (2013). Artificial Redirection of Sensation From Prosthetic Fingers to the Phantom Hand Map on Transradial Amputees: Vibrotactile Versus Mechanotactile Sensory Feedback. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2012.2217989

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.