Artificial Redirection of Sensation From Prosthetic Fingers to the Phantom Hand Map on Transradial Amputees: Vibrotactile Versus Mechanotactile Sensory Feedback
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
This work assesses the ability of transradial amputees to discriminate multi-site tactile stimuli in sensory discrimination tasks. It compares different sensory feedback modalities using an artificial hand prosthesis in: 1) a modality matched paradigm where pressure recorded on the five fingertips of the hand was fed back as pressure stimulation on five target points on the residual limb; and 2) a modality mismatched paradigm where the pressures were transformed into mechanical vibrations and fed back. Eight transradial amputees took part in the study and were divided in two groups based on the integrity of their phantom map; group A had a complete phantom map on the residual limb whereas group B had an incomplete or nonexisting map. The ability in localizing stimuli was compared with that of 10 healthy subjects using the vibration feedback and 11 healthy subjects using the pressure feedback (in a previous study), on their forearms, in similar experiments. Results demonstrate that pressure stimulation surpassed vibrotactile stimulation in multi-site sensory feedback discrimination. Furthermore, we demonstrate that subjects with a detailed phantom map had the best discrimination performance and even surpassed healthy participants for both feedback paradigms whereas group B had the worst performance overall. Finally, we show that placement of feedback devices on a complete phantom map improves multi-site sensory feedback discrimination, independently of the feedback modality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This technique may be superior to vibro-tactile substitution in that it reduces the grasping force error of prostheses, thereby providing more accurate spatial sensory information (Patterson and Katz, 1992; Antfolk et al., 2013a).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Antfolk et al., 2013a
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
That's my hand! Activity in premotor cortex reflects feeling of ownership of a limb
Ehrsson, H. H., Spence, C., & Passingham, R. E. (2004) · Science · doi:10.1126/science.1097011 · Cited by 1,348 · cited 1×
“the premotor cortex, [4].”
Talbot, W. H., Darian-Smith, I., Kornhuber, H. H., & Mountcastle, V. B. (1968) · Journal of Neurophysiology · doi:10.1152/jn.1968.31.2.301 · Cited by 990
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 5×
“This stimulation amplitude is so large (much greater than the discrimination amplitude threshold in humans at each given frequency [9]) that is clearly”
BackgroundInfluentialCortical Activity in Precision- Versus Power-Grip Tasks: An fMRI Study
Ehrsson, H. H., Fagergren, A., Jonsson, T., Westling, G., Johansson, R. S., & Forssberg, H. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.528 · Cited by 619 · cited 1×
“sophisticated control engaging large areas of the brain [1].”
BackgroundConsumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519 · cited 1×
“feedback is frequently invoked as one of the reasons for their rejection [7].”
BackgroundOn the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction
Cipriani, C., Zaccone, F., Micera, S., & Carrozza, M. C. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910708 · Cited by 453
Self-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 1×
“the control (like the peripheral nerves [8]) or (ii) noninvasively, by providing feedback to intact sensory systems normally not involved in the task (e.”
BackgroundSelf-citationDevelopment of human precision grip I: Basic coordination of force
Forssberg, H., Eliasson, A. C., Kinoshita, H., Johansson, R. S., & Westling, G. (1991) · Experimental Brain Research · doi:10.1007/bf00229422 · Cited by 369 · cited 1×
“coordinated lifting patterns observed in adults are not achieved in humans until 8-10 years of age [2], [3].”
BackgroundUpper limb amputees can be induced to experience a rubber hand as their own
Ehrsson, H. H., Rosen, B., Stockselius, A., Ragno, C., Kohler, P., & Lundborg, G. (2008) · Brain · doi:10.1093/brain/awn297 · Cited by 343 · cited 2×
“Both studies highlight that higher order brain processes are of importance to compensate for the reduction of mechanoreceptors, or for the loss of a hand [26], [29].”
BackgroundSelf-citationRobotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335 · cited 1×
“recent years, small sized, haptic devices have been developed and successfully tested on transradial amputees [20], and on shoulder disarticulation amputees that underwent the targeted muscle reinnervation procedure [21], [22].”
BackgroundVibrotactile localization on the arm: Effects of place, space, and age
Cholewiak, R. W., & Collins, A. A. (2003) · Perception & Psychophysics · doi:10.3758/bf03194834 · Cited by 325 · cited 1×
“[38] that showed that mechanoreceptors in the forearm decrease with age, but the ability to discriminate vibrotactile stimuli is maintained.”
BackgroundBehavioral and magnetoencephalographic correlates of plasticity in the adult human brain
Ramachandran, V. S. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.22.10413 · Cited by 297 · cited 1×
“remapping of referred sensations (also known as referred phantom sensations) [28].”
BackgroundThe SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286 · cited 3×
“[24].”
BackgroundInfluentialSelf-citationKuiken, T. A., Marasco, P. D., Lock, B. A., Harden, R. N., & Dewald, J. P. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706525104 · Cited by 283 · cited 1×
“recent years, small sized, haptic devices have been developed and successfully tested on transradial amputees [20], and on shoulder disarticulation amputees that underwent the targeted muscle reinnervation procedure [21], [22].”
BackgroundVibrotactile Frequency Discrimination in Human Hairy Skin
Mahns, D. A., Perkins, N. M., Sahai, V., Robinson, L., & Rowe, M. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00483.2005 · Cited by 231 · cited 1×
“to the MT display) [36], [37]; this probably explains the differences between the two methods.”
ResultAcute plasticity in the human somatosensory cortex following amputation
Borsook, D., Becerra, L., Fishman, S., Edwards, A., Jennings, C. L., Stojanovic, M., Papinicolas, L., Ramachandran, V. S., Gonzalez, R. G., & Breiter, H. (1998) · NeuroReport · doi:10.1097/00001756-199804200-00011 · Cited by 229 · cited 1×
“Imaging studies by Vilayanur Ramachandran showed that these sensations are due to rearrangement of cortical circuits occurring in the first hours after amputation [27].”
BackgroundThe role of feed-forward and feedback processes for closed-loop prosthesis control
Saunders, I., & Vijayakumar, S. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-60 · Cited by 193 · cited 1×
“Among these, Saunders and Vijayakumar [19] used a multisite vibrotactile array where the grip force of a prosthetic hand”
MethodForssberg, H., Kinoshita, H., Eliasson, A. C., Johansson, R. S., Westling, G., & Gordon, A. M. (1992) · Experimental Brain Research · doi:10.1007/bf00227253 · Cited by 193 · cited 1×
“coordinated lifting patterns observed in adults are not achieved in humans until 8-10 years of age [2], [3].”
BackgroundMyoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171 · cited 1×
“hand, wrist, elbow) and close-to-natural control [6], no somatic sensory feedback is intentionally provided to the amputee.”
BackgroundA Miniature Vibrotactile Sensory Substitution Device for Multifingered Hand Prosthetics
Cipriani, C., D'Alonzo, M., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2173342 · Cited by 164 · cited 3×
“The VT display [32] consisted of five miniaturized vibrators (Precision Microdrives, UK) (8 mm diameter, 3.”
BackgroundSelf-citationDesign and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · cited 1×
“Recent examples include, robotic prostheses [16], [17] or robotic interfaces [18] that were connected and tested with single-site vibrotactile systems”
BackgroundPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 2×
“Patterson and Katz [23] suggested that modality matched feedback reduces errors in the gripforce control of a robotic hand with respect to vibrotactile feedback; our study extends theirs and demonstrates that the modality matched paradigm surpasses the modality mismatched paradigm for multi-site sensory feedback discr…”
MethodResultReferral of sensation to an advanced humanoid robotic hand prosthesis
Rosén, B., Ehrsson, H. H., Antfolk, C., Cipriani, C., Sebelius, F., & Lundborg, G. (2009) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.3109/02844310903113107 · Cited by 113 · cited 1×
“Hence, with this setup from the perspective of the participant the hand looked like a part of their own body, and was likely to generate a strong “feeling of body ownership” of the prosthesis itself, as previously demonstrated [33].”
BackgroundSelf-citationA comparison of alternative means of providing sensory feedback on upper limb prostheses
Shannon, G. F. (1976) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478123 · Cited by 93 · cited 2×
“nature that promises higher acceptability compared to electrotactile stimulation [9], [15].”
BackgroundMethodA myoelectrically-controlled prosthesis with sensory feedback
Shannon, G. F. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02440956 · Cited by 92 · cited 1×
“Rohland [11], Shannon [12].”
Stability of phantom limb phenomena after upper limb amputation: A longitudinal study
Hunter, J. P., Katz, J. D., & Davis, K. D. (2008) · Neuroscience · doi:10.1016/j.neuroscience.2008.07.053 · Cited by 91
Impacts of selected stimulation patterns on the perception threshold in electrocutaneous stimulation
Geng, B., Yoshida, K., & Jensen, W. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-9 · Cited by 65 · cited 1×
“[14] to investigate the effects of different patterns on the perception threshold.”
BackgroundArtificial touch in a hand-prosthesis
Beeker, T. W., During, J., & den Hertog, A. (1967) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478841 · Cited by 55
Stepp, C. E., & Matsuoka, Y. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2170856 · Cited by 55 · cited 1×
“Recent examples include, robotic prostheses [16], [17] or robotic interfaces [18] that were connected and tested with single-site vibrotactile systems”
BackgroundAntfolk, C., Cipriani, C., Carrozza, M. C., Balkenius, C., Björkman, A., Lundborg, G., Rosén, B., & Sebelius, F. (2013) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2012.713435 · Cited by 52 · cited 2×
“recent years, small sized, haptic devices have been developed and successfully tested on transradial amputees [20], and on shoulder disarticulation amputees that underwent the targeted muscle reinnervation procedure [21], [22].”
BackgroundSelf-citationAntfolk, C., Balkenius, C., Lundborg, G., Rosén, B., & Sebelius, F. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-50 · Cited by 50 · cited 3×
“perceivable on the forearm in preliminary tests [20], [31].”
BackgroundSelf-citationSmartHand tactile display: A new concept for providing sensory feedback in hand prostheses
Antfolk, C., Balkenius, C., Rosén, B., Lundborg, G., & Sebelius, F. (2010) · Journal of Plastic Surgery and Hand Surgery · doi:10.3109/02844310903259090 · Cited by 39 · cited 1×
“experiments carried out by our group and published elsewhere [35].”
ResultSelf-citationDesign of a Multigrasp Transradial Prosthesis
Wiste, T. E., Dalley, S. A., Varol, H. A., & Goldfarb, M. T. (2011) · Journal of Medical Devices · doi:10.1115/1.4004653 · Cited by 39
Arieta, A. H., Yokoi, H., Arai, T., & Yu, W. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616097 · Cited by 37 · cited 1×
“Recently it was exploited in the Yokoi Hand [13] to deliver grip force feedback on a single skin-site, and by Geng et al.”
MethodSensory feedback for powered limb prostheses
Rohland, T. A. (1975) · Medical & Biological Engineering & Computing · doi:10.1007/bf02477743 · Cited by 34 · cited 1×
“Rohland [11], Shannon [12].”
Research works printed but not linked: 3
- weinstein, 1968, Intensive and extensive aspects of tactile sensitivity as a function of body part, sex, and laterality. The skin senses, The Skin Senses, 195
- weber, 1978, The Sense of Touch
- sacks, 1998, A Leg to Stand On
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Self-citationToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Haptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
“from [35] used with permission from IEEE.”
BackgroundD’Anna, E., Petrini, F. M., Artoni, F., Popovic, I., Simanić, I., Raspopovic, S., & Micera, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-11306-w · Cited by 215
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“Some of these stimulation techniques have been explored being deployed together [77]–[82]; whereas electrotactile, vibration and mechanical pressure have also been applied to phantom limb stimulation [18]–[23].”
BackgroundMethodInfluential
Metadata
- Authors
- Antfolk, C., D'Alonzo, M., Controzzi, M., Lundborg, G., Rosen, B., Sebelius, F., & Cipriani, C.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2013-01
- Volume
- 21
- Issue
- 1
- Pages
- 112-120
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2017326126
- Cited by
- 194
- References
- 35
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.