Control of Stair Ascent and Descent With a Powered Transfemoral Prosthesis
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
This paper presents a finite state-based control system for a powered transfemoral prosthesis that provides stair ascent and descent capability. The control system was implemented on a powered prosthesis and evaluated by a unilateral, transfemoral amputee subject. The ability of the powered prosthesis to provide stair ascent and descent capability was assessed by comparing the gait kinematics, as recorded by a motion capture system, with the kinematics provided by a passive prosthesis, in addition to those recorded from a set of healthy subjects. The results indicate that the powered prosthesis provides gait kinematics that are considerably more representative of healthy gait, relative to the passive prosthesis, for both stair ascent and descent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stair ascent and descent at different inclinations
Riener, R., Rabuffetti, M., & Frigo, C. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00162-x · Cited by 744 · cited 1×
“The inability to achieve biomechanically healthy stair ascent is largely due to the fact that the emulation of healthy stair ascent requires significant net positive power at the knee and ankle joints [1]–[3].”
An integrated biomechanical analysis of normal stair ascent and descent
McFadyen, B. J., & Winter, D. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90282-5 · Cited by 693 · cited 1×
“The inability to achieve biomechanically healthy stair ascent is largely due to the fact that the emulation of healthy stair ascent requires significant net positive power at the knee and ankle joints [1]–[3].”
A reliable gait phase detection system
Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928571 · Cited by 495
Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487 · cited 1×
“Although various powered lower limb prosthetic devices are emerging [4]–[11], to the knowledge of the authors, no literature is currently available regarding the implementation of stair descent or ascent with a powered knee and ankle transfemoral prosthesis.”
Powered Ankle--Foot Prosthesis Improves Walking Metabolic Economy
Au, S. K., Weber, J., & Herr, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2008747 · Cited by 487
Multiclass Real-Time Intent Recognition of a Powered Lower Limb Prosthesis
Varol, H. A., Sup, F., & Goldfarb, M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2034734 · Cited by 425 · cited 2×
“The authors have previously described controllers for level and sloped standing and walking [8]–[11].”
Self-citationPreliminary Evaluations of a Self-Contained Anthropomorphic Transfemoral Prosthesis
Sup, F., Varol, H. A., Mitchell, J., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2032688 · Cited by 298 · cited 2×
“This prosthesis is the second generation of the prosthesis prototype described in [8].”
Self-citationUpslope Walking With a Powered Knee and Ankle Prosthesis: Initial Results With an Amputee Subject
Sup, F., Varol, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2087360 · Cited by 283
Self-citationBiomechanical analysis of stair ambulation in lower limb amputees
Schmalz, T., Blumentritt, S., & Marx, B. S. K. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2006.04.008 · Cited by 185 · cited 1×
“For stair descent with the daily-use prosthesis, the subject chose the same strategy described in [13].”
MethodBellman, R. D., Holgate, M. A., & Sugar, T. G. (2008) · 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2008.4762887 · Cited by 163
Standing Stability Enhancement With an Intelligent Powered Transfemoral Prosthesis
Lawson, B. E., Varol, H. A., & Goldfarb, M. T. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2160173 · Cited by 58
Self-citationMultifunctional above-knee prosthesis for stairs' walking
Koganezawa, K., Fujimoto, H., & Kato, I. (1987) · Prosthetics and Orthotics International · doi:10.3109/03093648709078198 · Cited by 20 · cited 1×
“presented a passive transfemoral prosthesis designed to provide reciprocal stepping; however, no data was presented, and it was conceded that active knee extension and ankle plantarflexion were not possible [12].”
Research works printed but not linked: 2
- 10.1115/1.4001139 · doi:10.1115/1.4001139
- 10.1249/mss.0b013e31814538c8 · doi:10.1249/mss.0b013e31814538c8
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“include standing on inclined surfaces [108], running [137], and stair ascent [138].”
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Active lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
Robotic Leg Control with EMG Decoding in an Amputee with Nerve Transfers
Hargrove, L. J., Simon, A. M., Young, A. J., Lipschutz, R. D., Finucane, S. B., Smith, D. G., & Kuiken, T. A. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1300126 · Cited by 253
Quintero, D., Villarreal, D. J., Lambert, D. J., Kapp, S., & Gregg, R. D. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2794536 · Cited by 252
“Current approaches that use different controllers for distinct phases of gait [4], [6]–[13] have dozens of control gains and switching rules that require hours”
Metadata
- Authors
- Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2013-05
- Volume
- 21
- Issue
- 3
- Pages
- 466-473
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2017249007
- Cited by
- 206
- References
- 12
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.