HyVE: Hybrid Vibro-Electrotactile Stimulation for Sensory Feedback and Substitution in Rehabilitation
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Electro- or vibro-tactile stimulations were used in the past to provide sensory information in many different applications ranging from human manual control to prosthetics. The two modalities were used separately in the past, and we hypothesized that a hybrid vibro-electrotactile (HyVE) stimulation could provide two afferent streams that are independently perceived by a subject, although delivered in parallel and through the same skin location. We conducted psychophysical experiments where healthy subjects were asked to recognize the intensities of electroand vibro-tactile stimuli during hybrid and single modality stimulations. The results demonstrated that the subjects were able to discriminate the features of the two modalities within the hybrid stimulus, and that the cross-modality interaction was limited enough to allow better transmission of discrete information (messages) using hybrid versus singlemodality coding. The percentages of successful recognitions (mean ± standard deviation) for nine messages were 56 ± 11 % and 72 ± 8 % for two hybrid coding schemes, compared to 29 ±7 % for vibrotactile and 44 ± 4 % for electrotactile coding. The HyVE can be therefore an attractivesolution in numerous application for providing sensory feedbackin prostheses and rehabilitation, and it could be used to increase the resolution of a single variable or to simultaneously feedback two different variables.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416 · cited 1×
“It was demonstrated that the provision of an augmented haptic feedback can facilitate the motor learning [6].”
BackgroundElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Vibrotactile Display: Perception, Technology, and Applications
Choi, S., & Kuchenbecker, K. J. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2221071 · Cited by 496 · cited 2×
“motion (< 3Hz), flutter (10-70 Hz), or smooth vibration (100300 Hz) [10].”
BackgroundVibrotactile in-vehicle navigation system
Van Erp, J. B. F., & Van Veen, H. A. H. C. (2004) · Transportation Research Part F: Traffic Psychology and Behaviour · doi:10.1016/j.trf.2004.09.003 · Cited by 337
TIKL: Development of a Wearable Vibrotactile Feedback Suit for Improved Human Motor Learning
Lieberman, J., & Breazeal, C. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.907481 · Cited by 272 · cited 1×
“, robotic exoskeleton) [3] or to communicate the desired or erroneous activations and/or movements [4], [5].”
BackgroundDesign and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
Vibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150
Anani, A. B., Ikeda, K., & Körner, L. M. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457988 · Cited by 74 · cited 4×
“that used for single modality stimulation in [13], [26], [36], [38], [39].”
BackgroundMethodInfluentialPerceptual space and adjective rating of sinusoidal vibrations perceived via mobile device
Hwang, I., & Choi, S. (2010) · 2010 IEEE Haptics Symposium · doi:10.1109/haptic.2010.5444692 · Cited by 54 · cited 1×
“Qualitative aspects of generated vibrations are thoroughly investigated in [12] by using adjective rating along multiple dimensions.”
Background
Cited by
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
Restoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“Some of these stimulation techniques have been explored being deployed together [77]–[82]; whereas electrotactile, vibration and mechanical pressure have also been applied to phantom limb stimulation [18]–[23].”
BackgroundResultInfluentialA review of invasive and non-invasive sensory feedback in upper limb prostheses
Svensson, P., Wijk, U., Björkman, A., & Antfolk, C. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1332989 · Cited by 192
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“D’Alonzo et al. (2014a,b) used hybrid vibro-electro-tactile stimulation and found it to be an efficient approach for obtaining multi-channel sensory feedback.”
Metadata
- Authors
- D'Alonzo, M., Dosen, S., Cipriani, C., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-03
- Volume
- 22
- Issue
- 2
- Pages
- 290-301
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W1971208826
- Cited by
- 77
- References
- 9
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HyVE: Hybrid Vibro-Electrotactile Stimulation for Sensory Feedback and Substitution in Rehabilitation. https://app.cochat.ai/papers/10.1109/tnsre.2013.2266482
- The paper
- D'Alonzo, M., Dosen, S., Cipriani, C., & Farina, D. (2014). HyVE: Hybrid Vibro-Electrotactile Stimulation for Sensory Feedback and Substitution in Rehabilitation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2013.2266482
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.