Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
In recent years the number of active controllable joints in electrically powered hand-prostheses has increased significantly. However, the control strategies for these devices in current clinical use are inadequate as they require separate and sequential control of each degree-of-freedom (DoF). In this study we systematically compare linear and nonlinear regression techniques for an independent, simultaneous and proportional myoelectric control of wrist movements with two DoF. These techniques include linear regression, mixture of linear experts (ME), multilayer-perceptron, and kernel ridge regression (KRR). They are investigated offline with electro-myographic signals acquired from ten able-bodied subjects and one person with congenital upper limb deficiency. The control accuracy is reported as a function of the number of electrodes and the amount and diversity of training data providing guidance for the requirements in clinical practice. The results showed that KRR, a nonparametric statistical learning method, outperformed the other methods. However, simple transformations in the feature space could linearize the problem, so that linear models could achieve similar performance as KRR at much lower computational costs. Especially ME, a physiologically inspired extension of linear regression represents a promising candidate for the next generation of prosthetic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Learning with Kernels: Support Vector Machines, Regularization, Optimization, and Beyond
Schölkopf, B., & Smola, A. J. (2001) · The MIT Press eBooks · doi:10.7551/mitpress/4175.001.0001 · Cited by 11,703
Pattern Recognition and Machine Learning
(2006) · doi:10.1007/978-0-387-45528-0 · Cited by 9,824
(2006) · Springer eBooks · Cited by 8,123
Nonlinear Component Analysis as a Kernel Eigenvalue Problem
Schölkopf, B., Smola, A., & Müller, K.-R. (1998) · Neural Computation · doi:10.1162/089976698300017467 · Cited by 8,084
Kernel Methods for Pattern Analysis
Shawe-Taylor, J., & Cristianini, N. (2004) · Cambridge University Press eBooks · doi:10.1017/cbo9780511809682 · Cited by 6,587
Learning With Kernels: Support Vector Machines, Regularization, Optimization, and Beyond
Williams, C. K. I. (2003) · Journal of the American Statistical Association · doi:10.1198/jasa.2003.s269 · Cited by 4,281
An introduction to kernel-based learning algorithms
Muller, K.-R., Mika, S., Ratsch, G., Tsuda, K., & Scholkopf, B. (2001) · IEEE Transactions on Neural Networks · doi:10.1109/72.914517 · Cited by 3,473
Self-citationNeural Networks: Tricks of the Trade: Second Edition
(2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8 · Cited by 2,116
Self-citationA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 1×
“This window duration is within the acceptable time delay between user command and prosthesis action [14],[15].”
BackgroundTheoretical Foundations of the Potential Function Method in Pattern Recognition Learning
Айзерман, М. А. (1964) · Automation and Remote Control · Cited by 1,485
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Weighted Sums of Random Kitchen Sinks: Replacing minimization with randomization in learning
Rahimi, A., & Recht, B. (2008) · neural information processing systems · Cited by 893
Control of Fast-Reaching Movements by Muscle Synergy Combinations
d'Avella, A., Portone, A., Fernandez, L., & Lacquaniti, F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0830-06.2006 · Cited by 727
Introduction to machine learning for brain imaging
Lemm, S., Blankertz, B., Dickhaus, T., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.004 · Cited by 630
Recipes for the linear analysis of EEG
Parra, L. C., Spence, C. D., Gerson, A. D., & Sajda, P. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.032 · Cited by 569
Self-citationJiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Self-citationThe optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Myoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Self-citationResolving the Limb Position Effect in Myoelectric Pattern Recognition
Fougner, A., Scheme, E., Chan, A. D. C., Englehart, K., & Stavdahl, Ø. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163529 · Cited by 402
THEORIA MOTUS CORPORUM COELESTIUM IN SECTIONIBUS CONICIS SOLEM AMBIENTIUM
(2011) · Werke · doi:10.1017/cbo9781139058285.001 · Cited by 365
Linear and nonlinear methods for brain-computer interfaces
Muller, K.-R., Anderson, C. W., & Birch, G. E. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814484 · Cited by 360
Self-citationClassification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Muceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285
Self-citationNielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068298 · Cited by 260
Self-citationMachine-learning-based coadaptive calibration for brain-computer interfaces
Vidaurre, C., Sannelli, C., Müller, K.-R., & Blankertz, B. (2011) · Neural Computation · doi:10.1162/neco_a_00089 · Cited by 207
Self-citationJiang, N., Vest-Nielsen, J. L., Muceli, S., & Farina, D. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-42 · Cited by 181
Self-citationEffect of arm position on the prediction of kinematics from EMG in amputees
Jiang, N., Muceli, S., Graimann, B., & Farina, D. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0979-4 · Cited by 126
Self-citationSpatial Filtering for Robust Myoelectric Control
Hahne, J. M., Graimann, B., & Müller, K. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188799 · Cited by 105
Self-citationThe i-LIMB Hand and the DMC Plus Hand Compared: A Case Report
Van Der Niet, O., Reinders-Messelink, H. A., Bongers, R. M., Bouwsema, H., & Van Der Sluis, C. K. (2010) · Prosthetics & Orthotics International · doi:10.3109/03093641003767207 · Cited by 87
Simultaneous and proportional control of 2D wrist movements with myoelectric signals
Hahne, J. M., Rehbaum, H., Bießmann, F., Meinecke, F. C., Müller, K. R., Jiang, N., Farina, D., & Parra, L. C. (2012) · Machine learning for signal processing ... · doi:10.1109/mlsp.2012.6349712 · Cited by 49
Self-citationCross-Validation Optimization for Large Scale Structured Classification Kernel Methods
Seeger, M. (2008) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5555/1390681.1390720 · Cited by 21
Recognition of Combined Arm Motions Using Support Vector Machine
Geng, Y., Tao, D., Chen, L., & Li, G. (2011) · Lecture notes in electrical engineering · doi:10.1007/978-3-642-25992-0_108 · Cited by 11
A Temporal Kernel-Based Model for Tracking Hand Movements from Neural Activities
Shpigelman, L., Crammer, K., Paz, R., Vaadia, E., & Singer, Y. (2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.003.0016 · Cited by 10
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationMyoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, P. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s91102 · Cited by 342
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Ison, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“These linear models often outperform other models during real-time control [57, 198].”
Background
Metadata
- Authors
- Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-03
- Volume
- 22
- Issue
- 2
- Pages
- 269-279
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2027933188
- Cited by
- 365
- References
- 34
- FWCI
- 14.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.