Effects of Locomotion Mode Recognition Errors on Volitional Control of Powered Above-Knee Prostheses
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Recent studies have reported various methods that recognize amputees' intent regarding locomotion modes, which is potentially useful for volitional control of powered artificial legs. However, occasional errors in locomotion mode recognition are inevitable. When these intent recognition decisions are used for volitional prosthesis control, the effects of the decision errors on the operation of the prosthesis and user's task performance is unknown. Hence, the goals of this study were to 1) systematically investigate the effects of locomotion mode recognition errors on volitional control of powered prosthetic legs and the user's gait stability, and 2) identify the critical mode recognition errors that impact safe and confident use of powered artificial legs in lower limb amputees. Five able-bodied subjects and two above-knee (AK) amputees were recruited and tested when wearing a powered AK prosthesis. Four types of locomotion mode recognition errors with different duration and at different gait phases were purposely applied to the prosthesis control. The subjects' gait stabilities were subjectively and objectively quantified. The results showed that not all of the mode recognition errors in volitional prosthesis control disturb the subjects' gait stability. The effects of errors on the user's balance depended on 1) the gait phase when the errors happened and 2) the amount of mechanical work change applied on the powered knee caused by the errors. Based on the study results, "critical errors" were defined and suggested as a new index to evaluate locomotion mode recognition algorithms for artificial legs. The outcome of this study might aid the future design of volitionally-controlled powered prosthetic legs that are reliable and safe for practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542 · cited 3×
“It was because this type of errors was not observed in evaluation of our designed intent recognition system on above-knee amputees [8], [9].”
MethodResultSelf-citation
Research works printed but not linked: 20
- 10.1056/NEJMoa1300126 · DOI · Paper page
- 10.1007/s10846-013-9979-3 · DOI
- sup, 2009, A powered self-contained knee and ankle prosthesis for near normal gait in transfemoral amputees
- hogan, 1985, Impedance control: An approach to manipulation: Part II?Implementation, Trans ASME, 107, 8
- leonard, 1995, Gait Analysis Theory and Application
- 10.1109/EMBC.2013.6609818 · DOI · Paper page
- herr, 2008, Angular momentum in human walking, J Exp Biol, 211, 467, 10.1242/jeb.008573 · DOI · Paper page
- 10.1109/ROBOT.2004.1307421 · doi:10.1109/robot.2004.1307421
- 10.1093/gerona/53A.2.M126 · DOI
- hanavan, 1964, A mathematical model of the human body, 1
- 10.1177/0278364907084588 · DOI · Paper page
- 10.1682/JRRD.2008.09.0131 · doi:10.1682/jrrd.2008.09.0131
- 10.1109/TBME.2009.2034734 · DOI · Paper page
- 10.1016/j.neunet.2008.03.006 · DOI · Paper page
- 10.1109/TBME.2008.2003293 · DOI · Paper page
- 10.1109/JBHI.2012.2236563 · DOI · Paper page
- 0, The POWER KNEE
- 10.1016/S0003-9993(96)90151-3 · doi:10.1016/s0003-9993(96)90151-3
- 10.1016/S0966-6362(02)00010-3 · doi:10.1016/s0966-6362(02)00010-3
- nashner, 1980, Balance adjustments of humans perturbed while walking, J Neurophysiol, 44, 650, 10.1152/jn.1980.44.4.650 · DOI · Paper page
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“It is noteworthy that there are relatively few studies that document the impleme ntation of a complete hierarchical, multifunctional control structure similar to the one suggested he re and have demonstrated its use in a practical setting [24,67,115-120].”
BackgroundToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationFleming, A., Stafford, N., Huang, S., Hu, X., Ferris, D. P., & Huang, H. (. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1176 · Cited by 216
“Zhang et al systematically studied the influence of errors and delays in supervisory EMG control of robotic knee prostheses on human walking stability [101, 103].”
BackgroundResultSelf-citationXu, D., Feng, Y., Mai, J., & Wang, Q. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2870152 · Cited by 67
“The study mentioned in [9] has also obtained good results (part results could be seen in paper [32]) for the similar tasks”
MethodResult
Metadata
- Authors
- Zhang, F., Liu, M., & Huang, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-01
- Volume
- 23
- Issue
- 1
- Pages
- 64-72
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2326837543
- Cited by
- 82
- References
- 1
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Locomotion Mode Recognition Errors on Volitional Control of Powered Above-Knee Prostheses. https://app.cochat.ai/papers/10.1109/tnsre.2014.2327230
- The paper
- Zhang, F., Liu, M., & Huang, H. (2015). Effects of Locomotion Mode Recognition Errors on Volitional Control of Powered Above-Knee Prostheses. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2014.2327230
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.