Optimizing the Electrical Stimulation of Retinal Ganglion Cells
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Epiretinal prostheses aim to restore visual perception in the blind through electrical stimulation of surviving retinal ganglion cells (RGCs). While the effects of several waveform parameters (e.g., phase duration) on stimulation efficacy have been described, their relative influence remains unclear. Further, morphological differences between RGC classes represent a key source of variability that has not been accounted for in previous studies. Here we investigate the effect of electrical stimulus waveform parameters on activation of an anatomically homogenous RGC population and describe a technique for identifying optimal stimulus parameters to minimize the required stimulus charge. Responses of rat A2-type RGCs to a broad array of biphasic stimulation parameters, delivered via an epiretinal stimulating electrode (200 × 200 μ m) were recorded using whole-cell current clamp techniques. The data demonstrate that for rectangular charge-balanced stimuli, phase duration and polarity have the largest effect on threshold current amplitude-cells were most responsive to cathodic-first pulses of short phase duration. Waveform asymmetry and increases in interphase interval further reduced thresholds. Using optimal waveform parameters, we observed a drop in stimulus efficacy with increasing stimulation frequency. This was more pronounced for large cells. Our results demonstrate that careful choice of electrical waveform parameters can significantly improve the efficacy of electrical stimulation and the efficacy of implantable neurostimulators for the retina.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
[6] Correction for liquid junction potentials in patch clamp experiments
Neher, E. (1992) · Methods in Enzymology · doi:10.1016/0076-6879(92)07008-c · Cited by 1,132
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Prado-Guitierrez, P., Fewster, L. M., Heasman, J. M., McKay, C. M., & Shepherd, R. K. (2006) · Hearing Research · doi:10.1016/j.heares.2006.03.006 · Cited by 173
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
Jensen, R. J., Rizzo, J. F., Ziv, O. R., Grumet, A., & Wyatt, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1041 · Cited by 145
Cited by
Stimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
Guo, T., Yang, C. Y., Tsai, D., Muralidharan, M., Suaning, G. J., Morley, J. W., Dokos, S., & Lovell, N. H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00168 · Cited by 43
Haji Ghaffari, D., Akwaboah, A. D., Mirzakhalili, E., & Weiland, J. D. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3138297 · Cited by 10
“studies haven’t optimized for spatial RGC activity [8], [26], [27].”
Background
Metadata
- Authors
- Hadjinicolaou, A. E., Savage, C. O., Apollo, N. V., Garrett, D. J., Cloherty, S. L., Ibbotson, M. R., & O'Brien, B. J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-03
- Volume
- 23
- Issue
- 2
- Pages
- 169-178
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2127999231
- Cited by
- 47
- References
- 6
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.