A Novel Framework Based on FastICA for High Density Surface EMG Decomposition
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
This study presents a progressive FastICA peel-off (PFP) framework for high-density surface electromyogram (EMG) decomposition. The novel framework is based on a shift-invariant model for describing surface EMG. The decomposition process can be viewed as progressively expanding the set of motor unit spike trains, which is primarily based on FastICA. To overcome the local convergence of FastICA, a peel-off strategy, i.e., removal of the estimated motor unit action potential trains from the previous step, is used to mitigate the effects of the already identified motor units, so more motor units can be extracted. A constrained FastICA is applied to assess the extracted spike trains and correct possible erroneous or missed spikes. These procedures work together to improve decomposition performance. The proposed framework was validated using simulated surface EMG signals with different motor unit numbers (30, 70, 91) and SNRs (20, 10, and 0 dB). The results demonstrated relatively large numbers of extracted motor units and high accuracies (high F1-scores). The framework was tested with 111 trials of 64-channel electrode array experimental surface EMG signals during the first dorsal interosseous muscle contraction at different intensities. On average 14.1 ±5.0 motor units were identified from each trial of experimental surface EMG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Fast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246
Independent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
A Probabilistic Interpretation of Precision, Recall and F-Score, with Implication for Evaluation
Goutte, C., & Gaussier, E. (2005) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-31865-1_25 · Cited by 2,285 · cited 7×
“3 summarizes the average number of motor units with Recall 90 and Precision 90 .”
InfluentialModels of recruitment and rate coding organization in motor-unit pools.
Fuglevand, A. J., Winter, D. A., & Patla, A. E. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.70.6.2470 · Cited by 988 · cited 5×
“In [46], different motor unit discharge patterns were simulated (including those following or violating”
MethodInfluentialMultichannel Blind Source Separation Using Convolution Kernel Compensation
Holobar, A., & Zazula, D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.896108 · Cited by 648
On amplitude and frequency demodulation using energy operators
Maragos, P., Kaiser, J. F., & Quatieri, T. F. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.212729 · Cited by 539
Decoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383 · cited 2×
“Surface EMG decomposition has been a research focus in the past decade, and progress has been made with advancement in both surface EMG acquisition and processing techniques [22]–[27].”
MethodInfluence of anatomical, physical, and detection-system parameters on surface EMG
Farina, D., Cescon, C., & Merletti, R. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0309-2 · Cited by 373
High-yield decomposition of surface EMG signals
Nawab, S. H., Chang, S.-S., & De Luca, C. J. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.11.092 · Cited by 370
Estimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318 · cited 6×
“For example, among these efforts (with high-density surface EMG), a most distinguished achievement was by Holobar and colleagues, who developed decomposition methods based on convolution kernel compensation (CKC) [26], [36]–[38], which allowed extraction of a number of simultaneously discharged motor units from high-d…”
MethodInfluentialEMGLAB: An interactive EMG decomposition program
McGill, K. C., Lateva, Z. C., & Marateb, H. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.05.015 · Cited by 317
Lefever, R. S., & De Luca, C. J. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324881 · Cited by 300
James, C. J., & Gibson, O. J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816076 · Cited by 263
Holobar, A., Minetto, M. A., Botter, A., Negro, F., & Farina, D. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2041593 · Cited by 255
Blind source identification from the multichannel surface electromyogram
Holobar, A., & Farina, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r143 · Cited by 239
Modeling of surface myoelectric signals. I. Model implementation
Merletti, R., Lo Conte, L., Avignone, E., & Guglielminotti, P. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771190 · Cited by 208
Decomposition and quantitative analysis of clinical electromyographic signals
Stashuk, D. W. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00064-8 · Cited by 202
Synchronization of motor unit activity during voluntary contraction in man.
Datta, A. K., & Stephens, J. A. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp017991 · Cited by 200
High-Resolution Alignment of Sampled Waveforms
McGill, K. C., & Dorfman, L. J. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325413 · Cited by 187
Advances in Surface EMG: Recent Progress in Detection and Processing Techniques
Merletti, R., Aventaggiato, M., Botter, A., Holobar, A., Marateb, H., & Vieira, T. M. M. (2010) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v38.i4.10 · Cited by 176
A thin, flexible multielectrode grid for high-density surface EMG
Lapatki, B. G., van Dijk, J. P., Jonas, I. E., Zwarts, M. J., & Stegeman, D. F. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00521.2003 · Cited by 172
A technique for the detection, decomposition and analysis of the EMG signal
Mambrito, B., & De Luca, C. J. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90031-2 · Cited by 167
Correlation-based decomposition of surface electromyograms at low contraction forces
Holobar, A., & Zazula, D. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02350989 · Cited by 167
Using two-dimensional spatial information in decomposition of surface EMG signals
Kleine, B. U., van Dijk, J. P., Lapatki, B. G., Zwarts, M. J., & Stegeman, D. F. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.05.003 · Cited by 156
A Model-Based Spike Sorting Algorithm for Removing Correlation Artifacts in Multi-Neuron Recordings
Pillow, J. W., Shlens, J., Chichilnisky, E. J., & Simoncelli, E. P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0062123 · Cited by 155
Decomposition of surface EMG signals from cyclic dynamic contractions
Luca, C. J. D., Chang, S.-S., Roy, S. H., Kline, J. C., & Nawab, S. H. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00555.2014 · Cited by 153
Real-Time Motor Unit Identification From High-Density Surface EMG
Glaser, V., Holobar, A., & Zazula, D. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2247631 · Cited by 143
Lefever, R. S., Xenakis, A. P., & De Luca, C. J. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324882 · Cited by 140
Duchêne, J., & Hogrel, J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.821754 · Cited by 115
Nakamura, H., Yoshida, M., Kotani, M., Akazawa, K., & Moritani, T. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.01.004 · Cited by 107
Non-invasive characterization of motor unit behaviour in pathological tremor
Holobar, A., Glaser, V, Gallego, J. A., Dideriksen, J. L., & Farina, D. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056011 · Cited by 91
Automatic decomposition of selective needle-detected myoelectric signals
Stashuk, D., & De Bruin, H. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1330 · Cited by 88
The significance of grouping of motor unit activity
Taylor, A. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006930 · Cited by 88
Decomposition of indwelling EMG signals
Nawab, S. H., Wotiz, R. P., & De Luca, C. J. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00170.2007 · Cited by 86
From cell to movement: to what answers does EMG really contribute?
Rau, G., Schulte, E., & Dißelhorst-Klug, C. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.02.001 · Cited by 81
Accuracy assessment of CKC high-density surface EMG decomposition in biceps femoris muscle
Marateb, H. R., McGill, K. C., Holobar, A., Lateva, Z. C., Mansourian, M., & Merletti, R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066002 · Cited by 74
Fortune, E., & Lowery, M. M. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9756-4 · Cited by 70
Optimal resolution of superimposed action potentials
McGill, K. C. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1010847 · Cited by 65
Common Input to Motor Units of Digit Flexors During Multi-Digit Grasping
Winges, S. A., & Santello, M. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00516.2004 · Cited by 64
Watanabe, K., Gazzoni, M., Holobar, A., Miyamoto, T., Fukuda, K., Merletti, R., & Moritani, T. (2013) · Muscle & Nerve · doi:10.1002/mus.23828 · Cited by 58
MUAP Number Estimates in Surface EMG: Template-Matching Methods and Their Performance Boundaries
Zhou, P., & Rymer, W. Z. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000032463.26331.b3 · Cited by 50
Self-citationA decomposition algorithm for surface electrode-array electromyogram
Garcia, G. A., Okuno, R., & Azakawa, K. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1463398 · Cited by 50
Human alpha motoneurone discharge, a statistical analysis
Kranz, H., & Baumgartner, G. (1974) · Brain Research · doi:10.1016/0006-8993(74)90282-0 · Cited by 49
An approach to surface EMG decomposition based on higher-order cumulants
Zazula, D., & Holobar, A. (2005) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(05)80006-9 · Cited by 38
On the use of sparse signal decomposition in the analysis of multi-channel surface electromyograms
Theis, F. J., & García, G. A. (2005) · Signal Processing · doi:10.1016/j.sigpro.2005.05.032 · Cited by 30
Influence of contraction strength on single motor unit synchronous activity
Schmied, A., & Descarreaux, M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.02.165 · Cited by 29
Nakamura, H., Yoshida, M., Kotani, M., et al. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.01.005 · Cited by 27
Luca, C. J. D., & Kline, J. C. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00725.2013 · Cited by 14
Cited by
Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026027 · Cited by 647
Deep Learning for EMG-based Human-Machine Interaction: A Review
Xiong, D., Zhang, D., Zhao, X., & Zhao, Y. (2021) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2021.1003865 · Cited by 395
Tutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals
Del Vecchio, A., Holobar, A., Falla, D., Felici, F., Enoka, R. M., & Farina, D. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102426 · Cited by 372
A Review on Electromyography Decoding and Pattern Recognition for Human-Machine Interaction
Simao, M., Mendes, N., Gibaru, O., & Neto, P. (2019) · IEEE Access · doi:10.1109/access.2019.2906584 · Cited by 234
“Fast independent component analysis (FastICA) can also be used for the identification ofMUs from HD-EMG grids [38].”
MethodA review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
Metadata
- Authors
- Chen, M., & Zhou, P.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-01
- Volume
- 24
- Issue
- 1
- Pages
- 117-127
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2034255374
- Cited by
- 260
- References
- 49
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.