Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 239

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Blind source identification from the multichannel surface electromyogram

Open access
Holobar, A, Farina, D · 2014 · Physiological Measurement

Abstract

The spinal circuitries combine the information flow from the supraspinal centers with the afferent input to generate the neural codes that drive the human skeletal muscles. The muscles transform the neural drive they receive from alpha motor neurons into motor unit action potentials (electrical activity) and force. Thus, the output of the spinal cord circuitries can be examined noninvasively by measuring the electrical activity of skeletal muscles at the surface of the skin i.e. the surface electromyogram (EMG). The recorded multi-muscle EMG activity pattern is generated by mixing processes of neural sources that need to be identified from the recorded signals themselves, with minimal or no a priori information available. Recently, multichannel source separation techniques that rely minimally on a priori knowledge of the mixing process have been developed and successfully applied to surface EMG. They act at different scales of information extraction to identify: (a) the activation signals shared by synergistic skeletal muscles, (b) the specific neural activation of individual muscles, separating it from that of nearby muscles i.e. from crosstalk, and (c) the spike trains of the active motor neurons. This review discusses the assumptions made by these methods, the challenges and limitations, as well as examples of their current applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/35/7/r143

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Research works printed but not linked: 97

  1. 10.1038/ncpneuro0347 · DOI · Paper page
  2. Bernstein N A, 1967, The Co-Ordination and Regulation of Movements
  3. 10.1002/mus.20357 · DOI
  4. 10.1016/j.expneurol.2013.09.012 · DOI
  5. 10.1162/089976699300016863 · DOI · Paper page
  6. 10.1016/j.jelekin.2010.11.003 · doi:10.1016/j.jelekin.2010.11.003
  7. 10.1002/0470845899 · DOI · Paper page
  8. 10.1109/10.764949 · DOI · Paper page
  9. Comon P, 2010, Handbook of Blind Source Separation Independent Component Analysis and Blind Deconvolution
  10. 10.1152/jn.01377.2007 · DOI · Paper page
  11. 10.1523/JNEUROSCI.0830-06.2006 · DOI · Paper page
  12. 10.1038/nn1010 · DOI · Paper page
  13. 10.1152/jn.00009.2006 · DOI · Paper page
  14. De Luca C J, 1982, J. Physiol. (Lond.), 329, 129, 10.1113/jphysiol.1982.sp014294 · DOI · Paper page
  15. 10.1016/0013-4694(88)90169-1 · DOI · Paper page
  16. De Luca C J, 1993, J. Neurophysiol, 70, 2010, 10.1152/jn.1993.70.5.2010 · DOI
  17. Djuwari D, 2006, Electromyogr. Clin. Neurophysiol., 46, 295
  18. 10.1109/TBME.1984.325330 · DOI
  19. Farina D, 2001, Acta. Physiol. Pharmacol. Bulg., 26, 63
  20. 10.1109/RBME.2012.2183586 · DOI
  21. 10.1016/S1350-4533(99)00075-2 · doi:10.1016/s1350-4533(99)00075-2
  22. 10.1007/s00422-002-0309-2 · DOI · Paper page
  23. 10.1109/TBME.2004.828048 · DOI
  24. 10.1152/japplphysiol.01047.2003 · DOI
  25. 10.1109/TBME.2007.897844 · DOI
  26. 10.1109/TBME.2003.820998 · DOI · Paper page
  27. Farina D, 2013, J. Physiol., 591, 2403, 10.1113/jphysiol.2012.246082 · DOI
  28. 10.1109/MEMB.2005.1463398 · DOI
  29. 10.1109/TNN.2005.849840 · doi:10.1109/tnn.2005.849840
  30. 10.1152/jn.00727.2010 · DOI · Paper page
  31. 10.1186/1743-0003-9-76 · DOI
  32. Hannan M A, 2012, Sensors (Basel), 12, 297, 10.3390/s120100297 · DOI
  33. 10.1109/TBME.1980.326652 · DOI · Paper page
  34. 10.1007/BF02350989 · DOI · Paper page
  35. 10.1109/TSP.2007.896108 · DOI · Paper page
  36. 10.1007/978-3-540-74494-8_77 · DOI
  37. Holobar A, 2012, J. Neural. Eng., 9, 10.1088/1741-2560/9/5/056011 · DOI
  38. 10.1109/TNSRE.2010.2041593 · DOI · Paper page
  39. Hoyer P, 2004, J. Mach. Learn. Res., 5, 1457
  40. 10.1109/72.761722 · DOI · Paper page
  41. 10.1002/0471221317 · DOI · Paper page
  42. 10.1523/JNEUROSCI.2644-07.2007 · DOI · Paper page
  43. 10.1113/jphysiol.2003.057174 · DOI · Paper page
  44. 10.1186/1471-2202-14-39 · doi:10.1186/1471-2202-14-39
  45. 10.1109/TBME.2010.2084999 · doi:10.1109/tbme.2010.2084999
  46. 10.1109/TBME.2008.2007967 · DOI · Paper page
  47. 10.1186/1743-0003-9-42 · DOI · Paper page
  48. 10.1113/jphysiol.2011.215137 · DOI · Paper page
  49. 10.1038/44565 · DOI · Paper page
  50. Lee D D, 2001, Adv. Neural Inf. Process. Syst., 13, 556
  51. 10.1016/j.jelekin.2013.03.009 · doi:10.1016/j.jelekin.2013.03.009
  52. 10.1109/PROC.1977.10544 · DOI · Paper page
  53. 10.1016/j.joca.2007.03.024 · DOI
  54. 10.1186/1743-0003-8-25 · DOI · Paper page
  55. Marateb H R, 2011, J. Neural. Eng., 8
  56. 10.1016/j.jneumeth.2005.05.015 · DOI · Paper page
  57. Meigal A Y, 2013, Front. Neurol, 4, 135, 10.3389/fneur.2013.00135 · DOI
  58. 10.1002/0471678384 · DOI · Paper page
  59. 10.1615/CritRevBiomedEng.v38.i4.10 · DOI · Paper page
  60. 10.1097/JES.0b013e3182724817 · DOI
  61. 10.1007/BF03350820 · DOI
  62. 10.1186/1743-0003-10-79 · DOI
  63. 10.1109/TNSRE.2011.2178039 · DOI · Paper page
  64. 10.1152/jn.00559.2009 · DOI · Paper page
  65. 10.1109/TNSRE.2013.2282898 · DOI · Paper page
  66. 10.1073/pnas.91.16.7534 · DOI · Paper page
  67. 10.1007/s10916-010-9548-2 · DOI
  68. 10.1007/s13246-011-0066-4 · DOI
  69. Naik G R, 2008, Electromyogr. Clin. Neurophysiol, 48, 169
  70. 10.1016/j.jelekin.2004.01.004 · DOI
  71. 10.1016/j.jelekin.2004.01.005 · DOI
  72. 10.1016/j.clinph.2009.11.092 · DOI · Paper page
  73. 10.1097/AJP.0b013e318267252d · DOI
  74. 10.1113/jphysiol.2010.202473 · DOI
  75. 10.1016/j.neuroscience.2012.10.027 · DOI
  76. 10.1523/JNEUROSCI.2869-07.2008 · DOI · Paper page
  77. 10.1016/j.clinbiomech.2011.03.008 · DOI
  78. Raasch C C, 1999, J. Neurophysiol., 82, 515, 10.1152/jn.1999.82.2.515 · DOI · Paper page
  79. 10.1007/s00056-013-0193-5 · DOI
  80. Richard P D, 1983, J. Rehabil. Res. Dev., 20, 84
  81. 10.1016/S0924-980X(97)96670-4 · DOI
  82. 10.1046/j.1365-201X.1997.00247.x · DOI
  83. 10.1152/jn.00173.2011 · DOI
  84. 10.1177/0883073807313045 · doi:10.1177/0883073807313045
  85. 10.3389/fncom.2013.00079 · DOI
  86. 10.1109/TBME.2006.889202 · DOI
  87. 10.1016/j.sigpro.2005.05.032 · DOI
  88. 10.1152/jn.00681.2004 · DOI · Paper page
  89. 10.1152/jn.00960.2009 · DOI · Paper page
  90. 10.1152/jn.00810.2005 · DOI · Paper page
  91. 10.1152/jn.00222.2005 · DOI · Paper page
  92. 10.1097/AJP.0b013e3182272325 · doi:10.1097/ajp.0b013e3182272325
  93. 10.1016/j.diabres.2012.03.004 · DOI
  94. 10.12659/MSM.883927 · DOI
  95. 10.1179/2045772312Y.0000000037 · DOI
  96. 10.1111/j.1600-0838.2009.01010.x · doi:10.1111/j.1600-0838.2009.01010.x
  97. 10.1109/TNSRE.2013.2274658 · DOI

Cited by

See all 239

Metadata

Authors
Holobar, A., & Farina, D.
Venue
Physiological Measurement
Published
2014-06-19
Volume
35
Issue
7
Pages
R143-R165
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2063366067
Cited by
239
References
8
FWCI
11.75
Type
journal article
Language
en
Open access
bronze
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blind source identification from the multichannel surface electromyogram. https://app.cochat.ai/papers/10.1088/0967-3334/35/7/r143
The paper
Holobar, A., & Farina, D. (2014). Blind source identification from the multichannel surface electromyogram. Physiological Measurement. https://doi.org/10.1088/0967-3334/35/7/r143

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.