Control of a Wheelchair in an Indoor Environment Based on a Brain–Computer Interface and Automated Navigation
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The concept of controlling a wheelchair using brain signals is promising. However, the continuous control of a wheelchair based on unstable and noisy electroencephalogram signals is unreliable and generates a significant mental burden for the user. A feasible solution is to integrate a brain-computer interface (BCI) with automated navigation techniques. This paper presents a brain-controlled intelligent wheelchair with the capability of automatic navigation. Using an autonomous navigation system, candidate destinations and waypoints are automatically generated based on the existing environment. The user selects a destination using a motor imagery (MI)-based or P300-based BCI. According to the determined destination, the navigation system plans a short and safe path and navigates the wheelchair to the destination. During the movement of the wheelchair, the user can issue a stop command with the BCI. Using our system, the mental burden of the user can be substantially alleviated. Furthermore, our system can adapt to changes in the environment. Two experiments based on MI and P300 were conducted to demonstrate the effectiveness of our system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Formal Basis for the Heuristic Determination of Minimum Cost Paths
Hart, P., Nilsson, N., & Raphael, B. (1968) · IEEE Transactions on Systems Science and Cybernetics · doi:10.1109/tssc.1968.300136 · Cited by 12,738 · cited 1×
“The algorithm [21], which employs a best-first search and finds the least-cost path from a given initial node to a goal node, is applied to a set of points, including the current position of the wheelchair (start point), the destination (end point) selected by the BCI, and a sequence of waypoints based on Voronoi edge…”
MethodIturrate, I., Antelis, J. M., Kubler, A., & Minguez, J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2020347 · Cited by 512
Leeb, R., Friedman, D., Müller-Putz, G. R., Scherer, R., Slater, M., & Pfurtscheller, G. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/79642 · Cited by 479
Brain-Controlled Wheelchairs: A Robotic Architecture
Carlson, T., & del R. Millan, J. (2013) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2012.2229936 · Cited by 432
A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421 · cited 2×
“Subjects S4, S5, S6, and S7 had experience using the P300-based BCI system [25], and the two remaining subjects had never used the P300- and MI-based BCI systems.”
MethodResultSelf-citationA Brain Controlled Wheelchair to Navigate in Familiar Environments
Rebsamen, B., Guan, C., Zhang, H., Wang, C., Teo, C., Ang, M. H., & Burdet, E. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2049862 · Cited by 405 · cited 5×
“Using this system [13], the user selected a destination via a BCI.”
MethodInfluentialSelf-citationA brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400 · cited 1×
“Previous studies have demonstrated that some disabled people can perform in a similar manner to healthy persons when using either P300- or MI-based BCI [26]–[29].”
EEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X.-A., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 386 · cited 1×
“, patients with amyotrophic lateral sclerosis (ALS), obstacles exist with respect to the use of a common HMI, such as a keyboard; thus, BCI technology may be an alternative choice [8].”
BackgroundElectroencephalogram-based control of an electric wheelchair
Tanaka, K., Matsunaga, K., & Wang, H. O. (2005) · IEEE Transactions on Robotics · doi:10.1109/tro.2004.842350 · Cited by 361
An EEG-Based BCI System for 2-D Cursor Control by Combining Mu/Beta Rhythm and P300 Potential
Li, Y., Long, J., Yu, T., Yu, Z., Wang, C., Zhang, H., & Guan, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055564 · Cited by 298
Self-citation
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
A Multi-Branch 3D Convolutional Neural Network for EEG-Based Motor Imagery Classification
Zhao, X., Zhang, H., Zhu, G., You, F., Kuang, S., & Sun, L. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2938295 · Cited by 305
Self-citationFeature Extraction and Classification Methods for Hybrid fNIRS-EEG Brain-Computer Interfaces
Hong, K.-S., Khan, M. J., & Hong, M. J. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00246 · Cited by 283
Hong, K.-S., & Khan, M. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00035 · Cited by 267
Roy, A. M. (2022) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2022.105347 · Cited by 183
Tang, X., Li, W., Li, X., Ma, W., & Dang, X. (2020) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.113285 · Cited by 166
EEG classification using sparse Bayesian extreme learning machine for brain–computer interface
Jin, Z., Zhou, G., Gao, D., & Zhang, Y. (2020) · Neural Computing and Applications · doi:10.1007/s00521-018-3735-3 · Cited by 162
Li, Y., Pan, J., Long, J., Yu, T., Wang, F., Yu, Z., & Wu, W. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2469106 · Cited by 117
“For instance, an intelligent wheelchair may incorporate the advantages of both a BCI system and an autonomous navigation system [37], [43]–[46].”
BackgroundSelf-citationAghili, S. N., & Erfanian, A. (2023) · IEEE Access · doi:10.1109/access.2023.3313260 · Cited by 12
“application areas include control of wheelchair [10], [11],”
Background
Metadata
- Authors
- Zhang, R., Li, Y., Yan, Y., Zhang, H., Wu, S., Yu, T., & Gu, Z.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-01
- Volume
- 24
- Issue
- 1
- Pages
- 128-139
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2241109995
- Cited by
- 239
- References
- 24
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.