A High Performance Spelling System based on EEG-EOG Signals With Visual Feedback
Open accessThe DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Abstract
In this paper, we propose a highly accurate and fast spelling system that employs multi-modal electroencephalography-electrooculography (EEG-EOG) signals and visual feedback technology. Over the last 20 years, various types of speller systems have been developed in brain-computer interface and EOG/eye-tracking research; however, these conventional systems have a tradeoff between the spelling accuracy (or decoding) and typing speed. Healthy users and physically challenged participants, in particular, may become exhausted quickly; thus, there is a need for a speller system with fast typing speed while retaining a high level of spelling accuracy. In this paper, we propose the first hybrid speller system that combines EEG and EOG signals with visual feedback technology so that the user and the speller system can act cooperatively for optimal decision-making. The proposed spelling system consists of a classic row-column event-related potential (ERP) speller, an EOG command detector, and visual feedback modules. First, the online ERP speller calculates classification probabilities for all candidate characters from the EEG epochs. Second, characters are sorted by their probability, and the characters with the highest probabilities are highlighted as visual feedback within the row-column spelling layout. Finally, the user can actively select the character as the target by generating an EOG command. The proposed system shows 97.6% spelling accuracy and an information transfer rate of 39.6 (±13.2) [bits/min] across 20 participants. In our extended experiment, we redesigned the visual feedback and minimized the number of channels (four channels) in order to enhance the speller performance and increase usability. Most importantly, a new weighted strategy resulted in 100% accuracy and a 57.8 (±23.6) [bits/min] information transfer rate across six participants. This paper demonstrates that the proposed system can provide a reliable communication channel for practical speller applications and may be used to supplement existing systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
THE USE OF MULTIPLE MEASUREMENTS IN TAXONOMIC PROBLEMS
FISHER, R. A. (1936) · Annals of Eugenics · doi:10.1111/j.1469-1809.1936.tb02137.x · Cited by 15,227 · cited 1×
“After that, the linear discriminant analysis (LDA) [43] classifier was trained using these feature vectors. where S B and S w denote the between-class and within-class covariance matrices, respectively and w the hyper-plane for separation of the classes, which can be obtained by maximizing the…”
MethodNonlinear Component Analysis as a Kernel Eigenvalue Problem
Schölkopf, B., Smola, A., & Müller, K.-R. (1998) · Neural Computation · doi:10.1162/089976698300017467 · Cited by 8,084 · cited 1×
“The advanced feature extraction techniques, such as kernel PCA (Principal Component Analysis) [60] and non-linear machine learning techniques, such as logistic regression or support vector machines [61]–[63] would be considered further performance improvement.”
MethodBrain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“S PELLER systems [1]–[6] provide a new method of communication for patients who suffer from neuromuscular diseases, such as locked-in-syndrome (LIS) and paralysis.”
MethodEvent-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328 · cited 2×
“Brain-based spelling systems are less physically demanding than the EOG systems because they use components of the event-related potential (ERP) [9], [10].”
BackgroundMethodThe Nature of Statistical Learning Theory
Sain, S. R. (1996) · Technometrics · doi:10.1080/00401706.1996.10484565 · Cited by 5,434
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 3×
“During this period, rows and columns are flashed consecutively (classic row-column (RC) paradigm [6]).”
BackgroundMethodEye Tracking Methodology: Theory and Practice
Duchowski, A. T. (2003) · Springer eBooks · doi:10.1007/978-1-4471-3750-4 · Cited by 2,242
The P300 wave of the human event-related potential
Picton, T. W. (1992) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199210000-00002 · Cited by 1,908 · cited 1×
“Brain-based spelling systems are less physically demanding than the EOG systems because they use components of the event-related potential (ERP) [9], [10].”
MethodEye Tracking Methodology; Theory and Practice
(2007) · Qualitative Market Research: An International Journal · doi:10.1108/13522750710740862 · Cited by 1,313
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138 · cited 1×
“Eight discriminant intervals were extracted with a heuristic based on signed r-values [41], [42].”
MethodA breadth-first survey of eye-tracking applications
Duchowski, A. T. (2002) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03195475 · Cited by 1,061
Arns, M., de Ridder, S., Strehl, U., Breteler, M., & Coenen, A. (2009) · Clinical EEG and Neuroscience · doi:10.1177/155005940904000311 · Cited by 794 · cited 1×
“It has been commonly employed in clinical therapies for Attention Deficit Hyperactivity Disorder (ADHD) [14], stroke [15], and user training in BCIs [16].”
MethodEye Movement Analysis for Activity Recognition Using Electrooculography
Bulling, A., Ward, J. A., Gellersen, H., & Tröster, G. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.86 · Cited by 718
Introduction to machine learning for brain imaging
Lemm, S., Blankertz, B., Dickhaus, T., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.004 · Cited by 630 · cited 1×
“Eight discriminant intervals were extracted with a heuristic based on signed r-values [41], [42].”
MethodPfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625 · cited 1×
“To reduce the consumption of time, previous approaches have changed the experimental setting [27], [29], [33], [34], [53], [54] to enhance the ERP components, or they combined physiological signals such as EMG/EOG [19]–[22] or another brain component such as SSVEP/MI [70].”
MethodVarieties of the locked-in syndrome
Bauer, G., Gerstenbrand, F., & Rumpl, E. (1979) · Journal of Neurology · doi:10.1007/bf00313105 · Cited by 504 · cited 2×
“Additionally, our system can work in cases of locked-in-syndrome (LIS), which is a condition where a patient is aware but cannot move due to complete paralysis of nearly all voluntary muscles in the body except for vertical eye movement and blinking [67].”
BackgroundSystem for assisted mobility using eye movements based on electrooculography
Barea, R., Boquete, L., Mazo, M., & Lopez, E. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806829 · Cited by 486 · cited 4×
“At present, numerous studies have explored the possibility of designing EOG-based Human-Computer Interfaces (HCIs) and have had positive outcomes [7]–[10].”
BackgroundMethodResultInfluentialTwenty years of eye typing: systems and design issues
Majaranta, P., & Räihä, K.-J. (2002) · Proceedings of the symposium on Eye tracking research & applications - ETRA '02 · doi:10.1145/507072.507076 · Cited by 483
Classifying Single Trial EEG: Towards Brain Computer Interfacing
Blankertz, B., Curio, G., & Müller, K.-R. (2002) · Advances in Neural Information Processing Systems 14 · doi:10.7551/mitpress/1120.003.0025 · Cited by 467
Kübler, A., & Birbaumer, N. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.019 · Cited by 441 · cited 1×
“Previous BCI studies have argued that a minimum accuracy level of 70% is needed for efficient communication [45].”
BackgroundAn improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403 · cited 1×
“Therefore, predefining a fixed number of sequences as the threshold [29], [64], [65] will inevitably lead to suboptimal results.”
BackgroundLinear and nonlinear methods for brain-computer interfaces
Muller, K.-R., Anderson, C. W., & Birch, G. E. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814484 · Cited by 360 · cited 1×
“The advanced feature extraction techniques, such as kernel PCA (Principal Component Analysis) [60] and non-linear machine learning techniques, such as logistic regression or support vector machines [61]–[63] would be considered further performance improvement.”
MethodBrain–computer interface (BCI) operation: optimizing information transfer rates
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2003) · Biological Psychology · doi:10.1016/s0301-0511(03)00073-5 · Cited by 247 · cited 1×
“In summary, the ITR corresponds to the amount of information received by the system per unit time [44].”
BackgroundSoekadar, S. R., Witkowski, M., Gómez, C., Opisso, E., Medina, J., Cortese, M., Cempini, M., Carrozza, M. C., Cohen, L. G., Birbaumer, N., et al. (2016) · Science Robotics · doi:10.1126/scirobotics.aag3296 · Cited by 242 · cited 2×
“To reduce the consumption of time, previous approaches have changed the experimental setting [27], [29], [33], [34], [53], [54] to enhance the ERP components, or they combined physiological signals such as EMG/EOG [19]–[22] or another brain component such as SSVEP/MI [70].”
BackgroundMethodA practical EMG-based human-computer interface for users with motor disabilities.
Barreto, A. B., Scargle, S., & Adjouadi, M. (2000) · PubMed · Cited by 227
EMG-based hand gesture recognition for realtime biosignal interfacing
Kim, J., Mastnik, S., & André, E. (2008) · Proceedings of the 13th international conference on Intelligent user interfaces · doi:10.1145/1378773.1378778 · Cited by 220 · cited 2×
“In principle, movement detection of any body part, such as tongue [49], [50], hand [51], feet [52], etc. [21], is possible.”
BackgroundMethodShindo, K., Kawashima, K., Ushiba, J., Ota, N., Ito, M., Ota, T., Kimura, A., & Liu, M. (2011) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0859 · Cited by 216 · cited 1×
“It has been commonly employed in clinical therapies for Attention Deficit Hyperactivity Disorder (ADHD) [14], stroke [15], and user training in BCIs [16].”
MethodMa, J., Zhang, Y., Cichocki, A., & Matsuno, F. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369483 · Cited by 209 · cited 6×
“In principle, movement detection of any body part, such as tongue [49], [50], hand [51], feet [52], etc. [21], is possible.”
BackgroundMethodInfluentialDesign of a Novel Efficient Human–Computer Interface: An Electrooculagram Based Virtual Keyboard
Usakli, A. B., & Gurkan, S. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2030923 · Cited by 198 · cited 2×
“5) Following participant feedback for greater comfort, the winking task for the selection of the target character was replaced by eye movement (eye-up) [11].”
BackgroundEOG-based Human–Computer Interface system development
Deng, L. Y., Hsu, C.-L., Lin, T.-C., Tuan, J.-S., & Chang, S.-M. (2009) · Expert Systems with Applications · doi:10.1016/j.eswa.2009.10.017 · Cited by 193 · cited 5×
“While in this study, we have used a simple threshold-based EOG detection method, similar to earlier approaches [7], [8], [12], [46], a wide variety of other eye movement algorithms and feature extraction methods are available.”
BackgroundMethodResultInfluentialAn Adaptive P300-Based Online Brain–Computer Interface
Lenhardt, A., Kaper, M., & Ritter, H. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.912816 · Cited by 190 · cited 1×
“Lenhardt et al. [71] proposed the P300 speller system which dynamically limits the number of subtrial presentations according to the user’s current online performance.”
BackgroundGaze-independent brain–computer interfaces based on covert attention and feature attention
Treder, M. S., Schmidt, N. M., & Blankertz, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066003 · Cited by 182 · cited 1×
“In these cases, like in total locked-in syndrome, gaze-independent speller systems have been proposed, and we would point your attention to Treder et al. [68] who developed a two-stage visual speller based on covert spatial attention and non-spatial feature attention.”
BackgroundKaufmann, T., Schulz, S. M., Köblitz, A., Renner, G., Wessig, C., & Kübler, A. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.11.006 · Cited by 172 · cited 5×
“A prime example for boosting the strength of the ERP response is a study by Kaufmann et al. [33] where images of faces were used as stimuli to evoke stronger ERP responses.”
BackgroundMethodInfluentialJin, J., Allison, B. Z., Kaufmann, T., Kübler, A., Zhang, Y., Wang, X., & Cichocki, A. S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0049688 · Cited by 164 · cited 4×
“To reduce the consumption of time, previous approaches have changed the experimental setting [27], [29], [33], [34], [53], [54] to enhance the ERP components, or they combined physiological signals such as EMG/EOG [19]–[22] or another brain component such as SSVEP/MI [70].”
BackgroundMethodInfluentialEffects of feedback and dwell time on eye typing speed and accuracy
Majaranta, P., MacKenzie, I. S., Aula, A., & Räihä, K. (2006) · Universal Access in the Information Society · doi:10.1007/s10209-006-0034-z · Cited by 162 · cited 1×
“Previous studies have shown that visual or auditory feedback positively impacts typing speed, accuracy, and subjective experience [17].”
BackgroundOnline Detection of P300 and Error Potentials in a BCI Speller
Dal Seno, B., Matteucci, M., & Mainardi, L. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/307254 · Cited by 145 · cited 3×
“To reduce the consumption of time, previous approaches have changed the experimental setting [27], [29], [33], [34], [53], [54] to enhance the ERP components, or they combined physiological signals such as EMG/EOG [19]–[22] or another brain component such as SSVEP/MI [70].”
BackgroundMethodAn EOG-Based Human–Machine Interface for Wheelchair Control
Huang, Q., He, S., Wang, Q., Gu, Z., Peng, N., Li, K., Zhang, Y., Shao, M., & Li, Y. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2732479 · Cited by 136 · cited 5×
“The decoding accuracies of both systems exhibited a strong performance of 94.4% [12] and 96.7% [13] for the 40 symbols in the speller and the 13 symbols of wheelchair system, respectively (see Table I).”
BackgroundMethodInfluentialAllison, B. Z., & Pineda, J. A. (2005) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2005.02.007 · Cited by 135 · cited 1×
“Secondly, we varied the original experimental setup in regards to electrode montages, inter-stimulus interval (ISI), stimulus onset asynchrony (SOA), and target-to-target interval (TTI) [28], [35].”
MethodA hybrid BCI speller paradigm combining P300 potential and the SSVEP blocking feature
Xu, M., Qi, H., Wan, B., Yin, T., Liu, Z., & Ming, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026001 · Cited by 133
An asynchronous wheelchair control by hybrid EEG–EOG brain–computer interface
Wang, H., Li, Y., Long, J., Yu, T., & Gu, Z. (2014) · Cognitive Neurodynamics · doi:10.1007/s11571-014-9296-y · Cited by 132 · cited 1×
“While there have been numerous types of EEG-EOG approaches in hybrid BCI systems, the target applications have mostly been in robotics systems such as wheelchair [19], [20],”
BackgroundTarget Selection With Hybrid Feature for BCI-Based 2-D Cursor Control
Long, J., Li, Y., Yu, T., & Gu, Z. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2167718 · Cited by 128 · cited 1×
“Previous studies have shown performance increases from combinations of ERP and other components, such as SSVEP [55]–[57], motor-imagery (MI) [58], [59], error-related potentials (ERRP) [53], and others [54].”
BackgroundA Hybrid Brain–Computer Interface Based on the Fusion of P300 and SSVEP Scores
Yin, E., Zeyl, T., Saab, R., Chau, T., Hu, D., & Zhou, Z. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2403270 · Cited by 120 · cited 1×
“Previous studies have shown performance increases from combinations of ERP and other components, such as SSVEP [55]–[57], motor-imagery (MI) [58], [59], error-related potentials (ERRP) [53], and others [54].”
BackgroundLee, M.-H., Fazli, S., Mehnert, J., & Lee, S. (2015) · Pattern Recognition · doi:10.1016/j.patcog.2015.03.010 · Cited by 119 · cited 2×
“To see a clear difference between our proposed framework and the conventional threshold-based approach, we have employed a pseudo-online technique [59], [66] to make grounds for equal comparison.”
BackgroundMethodSelf-citationAn Efficient ERP-Based Brain-Computer Interface Using Random Set Presentation and Face Familiarity
Yeom, S.-K., Fazli, S., Müller, K., & Lee, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111157 · Cited by 117 · cited 4×
“Therefore, predefining a fixed number of sequences as the threshold [29], [64], [65] will inevitably lead to suboptimal results.”
BackgroundMethodInfluentialSelf-citationA novel brain-computer interface based on the rapid serial visual presentation paradigm
Acqualagna, L., Treder, M. S., Schreuder, M., & Blankertz, B. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5626548 · Cited by 102 · cited 1×
“Additionally, Acqualagna et al. [69] proposed a novel BCI paradigm consisting of a central rapid serial visual presentation (RSVP) of the stimuli that shows promising results.”
BackgroundEye typing using Markov and active appearance models
Hansen, D. W., Hansen, J. P., Nielsen, M., Johansen, A. S., & Stegmann, M. B. (2003) · Sixth IEEE Workshop on Applications of Computer Vision, 2002. (WACV 2002). Proceedings. · doi:10.1109/acv.2002.1182170 · Cited by 100
Lalitharatne, T. D., Teramoto, K., Hayashi, Y., & Kiguchi, K. (2013) · Paladyn Journal of Behavioral Robotics · doi:10.2478/pjbr-2013-0009 · Cited by 95 · cited 3×
“To reduce the consumption of time, previous approaches have changed the experimental setting [27], [29], [33], [34], [53], [54] to enhance the ERP components, or they combined physiological signals such as EMG/EOG [19]–[22] or another brain component such as SSVEP/MI [70].”
BackgroundMethodPattern Recognition & Machine Learning
Anzai, Y. (1992) · Elsevier eBooks · doi:10.1016/c2009-0-22409-3 · Cited by 90
An online hybrid BCI system based on SSVEP and EMG
Lin, K. C., Cinetto, A., Wang, Y., Chen, X., Gao, S., & Gao, X. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026020 · Cited by 79 · cited 1×
“Lin et al. [26] proposed a hybrid BCI system based on the steady-state visually evoked potential (SSVEP) and electromyography (EMG).”
A P300-Based Brain–Computer Interface: Effects of Interface Type and Screen Size
Li, Y., Nam, C. S., Shadden, B. B., & Johnson, S. L. (2010) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2011.535753 · Cited by 73 · cited 4×
“To reduce the consumption of time, previous approaches have changed the experimental setting [27], [29], [33], [34], [53], [54] to enhance the ERP components, or they combined physiological signals such as EMG/EOG [19]–[22] or another brain component such as SSVEP/MI [70].”
BackgroundMethodInfluentialBayesian Approach to Dynamically Controlling Data Collection in P300 Spellers
Morton, K. D., Colwell, K. A., Ryan, D. B., Sellers, E. W., & Collins, L. M. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2253125 · Cited by 73 · cited 1×
“Furthermore, a Bayes classifier with a threshold probability [72], or others that use language models [31], [38] have also been proposed for increasing the ITR.”
MethodA novel eye movement detection algorithm for EOG driven human computer interface
Lv, Z., Wu, X., Li, M., & Zhang, D. (2009) · Pattern Recognition Letters · doi:10.1016/j.patrec.2009.12.017 · Cited by 71 · cited 2×
“Lv et al. [47] proposed an eye movement pattern matching and spectral entropy algorithm to detect the endpoints of EOG pulses, which can improve the performance in a noisy background.”
BackgroundMethodTargeting an efficient target-to-target interval for P300 speller brain–computer interfaces
Jin, J., Sellers, E. W., & Wang, X. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0868-x · Cited by 71 · cited 3×
“Secondly, we varied the original experimental setup in regards to electrode montages, inter-stimulus interval (ISI), stimulus onset asynchrony (SOA), and target-to-target interval (TTI) [28], [35].”
MethodResultA Single-Channel EOG-Based Speller
He, S., & Li, Y. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2716109 · Cited by 67 · cited 3×
“The decoding accuracies of both systems exhibited a strong performance of 94.4% [12] and 96.7% [13] for the 40 symbols in the speller and the 13 symbols of wheelchair system, respectively (see Table I).”
BackgroundMethodInfluentialP300-Based Brain-Neuronal Computer Interaction for Spelling Applications
Postelnicu, C.-C., & Talaba, D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2228645 · Cited by 67 · cited 1×
“Similar approaches where the visual stimulus were divided into a number of sections with the EOG and EEG modalities used to classify the target section and the symbol, respectively, have been proposed based on the dual-monitor [25] and half checkerboard paradigms [23].”
MethodTownsend, G., Shanahan, J. L., Ryan, D. B., & Sellers, E. W. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.08.041 · Cited by 58 · cited 2×
“In our results, the conventional RC-based ERP has a performance that is similar to previously reported findings [28]–[31], [36]–[38].”
ResultSpeier, W. F., Arnold, C. W., Lu, J., Deshpande, A., & Pouratian, N. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2300091 · Cited by 57 · cited 4×
“Furthermore, a Bayes classifier with a threshold probability [72], or others that use language models [31], [38] have also been proposed for increasing the ITR.”
BackgroundMethodResultInfluentialUse of a Green Familiar Faces Paradigm Improves P300-Speller Brain-Computer Interface Performance
Li, Q., Liu, S., Li, J., & Bai, O. (2015) · PLOS ONE · doi:10.1371/journal.pone.0130325 · Cited by 53
Foot Tapping for Mobile Interaction
Crossan, A., Brewster, S. A., & Ng, A. (2010) · Electronic workshops in computing · doi:10.14236/ewic/hci2010.49 · Cited by 50 · cited 2×
“In principle, movement detection of any body part, such as tongue [49], [50], hand [51], feet [52], etc. [21], is possible.”
BackgroundMethodUşaklı, A. B., Gürkan, S., Fabio Aloise, A., Vecchiato, G., & Babiloni, F. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333742 · Cited by 47 · cited 1×
“Usakli et al. [18] compared the spelling performance of the EOG and EEG modalities independently.”
BackgroundHybrid Brain-Computer Interface (BCI) based on the EEG and EOG signals
Jiang, J., Zhou, Z., Yin, E., Yu, Y., & Hu, D. (2014) · Bio-Medical Materials and Engineering · doi:10.3233/bme-141111 · Cited by 43 · cited 2×
“Other types of hybrid BCI systems have used an EOG signal as the main modality for decoding a target symbol [21] or independently utilized each modality to extend the available number of classes [24].”
MethodPuanhvuan, D., Khemmachotikun, S., Wechakarn, P., Wijarn, B., & Wongsawat, Y. (2017) · Cognitive Neurodynamics · doi:10.1007/s11571-017-9424-6 · Cited by 41 · cited 2×
“To reduce the consumption of time, previous approaches have changed the experimental setting [27], [29], [33], [34], [53], [54] to enhance the ERP components, or they combined physiological signals such as EMG/EOG [19]–[22] or another brain component such as SSVEP/MI [70].”
BackgroundMethodP300 Brain-Computer Interface Design for Communication and Control Applications
Wang, C., Guan, C., & Zhang, H. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615703 · Cited by 41 · cited 1×
“Therefore, predefining a fixed number of sequences as the threshold [29], [64], [65] will inevitably lead to suboptimal results.”
BackgroundUtilizing a Language Model to Improve Online Dynamic Data Collection in P300 Spellers
Mainsah, B. O., Colwell, K. A., Collins, L. M., & Morton, K. D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2321290 · Cited by 32 · cited 4×
“Furthermore, a Bayes classifier with a threshold probability [72], or others that use language models [31], [38] have also been proposed for increasing the ITR.”
BackgroundMethodResultInfluentialDevelopment of an open source platform for brain-machine interface: openBMI
Lee, M.-H., Fazli, S., Kim, K.-T., & Lee, S. (2016) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/iww-bci.2016.7457440 · Cited by 23 · cited 1×
“The paradigm code was developed with the Psychophysics Toolbox (http://psychtoolbox.com) and OpenBMI [39], [40] in Matlab (MathWorks; MA, USA).”
MethodSelf-citationA hybrid EOG-P300 BCI with dual monitors
Koo, B., Nam, Y., & Choi, S. (2014) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/iww-bci.2014.6782566 · Cited by 18 · cited 1×
“Similar approaches where the visual stimulus were divided into a number of sections with the EOG and EEG modalities used to classify the target section and the symbol, respectively, have been proposed based on the dual-monitor [25] and half checkerboard paradigms [23].”
MethodOpenBMI: A real-time data analysis toolbox for Brain-Machine Interfaces
Lee, M.-H., Kim, K.-T., Kee, Y.-J., Jeong, J.-H., Kim, S., Fazli, S., & Lee, S. (2016) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2016.7844513 · Cited by 16 · cited 1×
“The paradigm code was developed with the Psychophysics Toolbox (http://psychtoolbox.com) and OpenBMI [39], [40] in Matlab (MathWorks; MA, USA).”
MethodSelf-citationA dynamic submatrix-based P300 online brain–computer interface
Shen, J., Liang, J., Shi, J., & Wang, Y. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.09.005 · Cited by 9
Cited by
Subject-Independent Brain–Computer Interfaces Based on Deep Convolutional Neural Networks
Kwon, O.-Y., Lee, M.-H., Guan, C., & Lee, S.-W. (2020) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2019.2946869 · Cited by 347
Self-citationNeural Decoding of Imagined Speech and Visual Imagery as Intuitive Paradigms for BCI Communication
Lee, S.-H., Lee, M., & Lee, S.-W. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3040289 · Cited by 166
“Unlike conventional paradigms such as SSVEP or MI [15], [16], imagined speech and visual imagery classes can have constant discrimination between classes despite the increase in the number of classes [6].”
BackgroundSelf-citationBang, J.-S., Lee, M.-H., Fazli, S., Guan, C., & Lee, S.-W. (2022) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2020.3048385 · Cited by 166
“B RAIN–COMPUTER interfaces (BCIs) provide an alternative pathway between humans and external devices by allowing users to control prostheses using their intentions, which are decoded from brain signals [1]–[5].”
BackgroundSelf-citation
Metadata
- Authors
- Lee, M.-H., Williamson, J., Won, D.-O., Fazli, S., & Lee, S.-W.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2018-07
- Volume
- 26
- Issue
- 7
- Pages
- 1443-1459
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2804035092
- Cited by
- 163
- References
- 69
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.