The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Towards Wearability in Fingertip Haptics: A 3-DoF Wearable Device for Cutaneous Force Feedback
Abstract
Wearability will significantly increase the use of haptics in everyday life, as has already happened for audio and video technologies. The literature on wearable haptics is mainly focused on vibrotactile stimulation, and only recently, wearable devices conveying richer stimuli, like force vectors, have been proposed. This paper introduces design guidelines for wearable haptics and presents a novel 3-DoF wearable haptic interface able to apply force vectors directly to the fingertip. It consists of two platforms: a static one, placed on the back of the finger, and a mobile one, responsible for applying forces at the finger pad. The structure of the device resembles that of parallel robots, where the fingertip is placed in between the static and the moving platforms. This work presents the design of the wearable display, along with the quasi-static modeling of the relationship between the applied forces and the platform's orientation and displacement. The device can exert up to 1.5 N, with a maximum platform inclination of 30 degree. To validate the device and verify its effectiveness, a curvature discrimination experiment was carried out: employing the wearable device together with a popular haptic interface improved the performance with respect of employing the haptic interface alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calculation of signal detection theory measures
Stanislaw, H., & Todorov, N. (1999) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03207704 · Cited by 2,673
Robot Analysis: The Mechanics of Serial and Parallel Manipulators
Tsai, L. (1999) · Cited by 1,848
Psychophysics: The Fundamentals
Gescheider, G. A. (2015) · Cited by 1,273
Hayward, V., Astley, O. R., Cruz‐Hernandez, M., Grant, D., & Robles‐De‐La‐Torre, G. (2004) · Sensor Review · doi:10.1108/02602280410515770 · Cited by 600
Methods for haptic feedback in teleoperated robot‐assisted surgery
Okamura, A. M. (2004) · Industrial Robot: An International Journal · doi:10.1108/01439910410566362 · Cited by 493
Finger pad friction and its role in grip and touch
Adams, M. J., Johnson, S. A., Lefèvre, P., Lévesque, V., Hayward, V., André, T., & Thonnard, J.-L. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0467 · Cited by 293
TIKL: Development of a Wearable Vibrotactile Feedback Suit for Improved Human Motor Learning
Lieberman, J., & Breazeal, C. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.907481 · Cited by 272 · cited 1×
“In [4], the authors developed a 5-DoF arm suit able to guide the motion of the wearer by providing solely vibrotactile feedback.”
Gravity grabber: wearable haptic display to present virtual mass sensation
Minamizawa, K., Fukamachi, S., Kajimoto, H., Kawakami, N., & Tachi, S. (2007) · ACM SIGGRAPH 2007 emerging technologies · doi:10.1145/1278280.1278289 · Cited by 244
Srinivasan, M. A., & Dandekar, K. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2795945 · Cited by 202
An arm exoskeleton system for teleoperation and virtual environments applications
Bergamasco, M., Allotta, B., Bosio, L., Ferretti, L., Parrini, G., Prisco, G. M., Salsedo, F., & Sartini, G. (2002) · Proceedings of the 1994 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1994.351286 · Cited by 196
Cited by
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Self-citationHaptics: The Present and Future of Artificial Touch Sensation
Culbertson, H., Schorr, S. B., & Okamura, A. M. (2018) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-105043 · Cited by 431
Robotic tactile perception of object properties: A review
Luo, S., Bimbo, J., Dahiya, R., & Liu, H. (2017) · Mechatronics · doi:10.1016/j.mechatronics.2017.11.002 · Cited by 425
Wearable Soft Technologies for Haptic Sensing and Feedback
Yin, J., Hinchet, R., Shea, H., & Majidi, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007428 · Cited by 325
Benko, H., Holz, C., Sinclair, M., & Ofek, E. (2016) · Proceedings of the 29th Annual Symposium on User Interface Software and Technology · doi:10.1145/2984511.2984526 · Cited by 298
Whitmire, E., Benko, H., Holz, C., Ofek, E., & Sinclair, M. (2018) · Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3173660 · Cited by 264
Haptic display for virtual reality: progress and challenges
WANG, D., GUO, Y., LIU, S., ZHANG, Y., XU, W., & XIAO, J. (2019) · Virtual Reality & Intelligent Hardware · doi:10.3724/sp.j.2096-5796.2019.0008 · Cited by 262
A Study on Immersion and Presence of a Portable Hand Haptic System for Immersive Virtual Reality
Kim, M., Jeon, C., & Kim, J. (2017) · Sensors · doi:10.3390/s17051141 · Cited by 175
Haptic Codecs for the Tactile Internet
Steinbach, E., Strese, M., Eid, M., Liu, X., Bhardwaj, A., Liu, Q., Al-Ja'Afreh, M., Mahmoodi, T., Hassen, R., El Saddik, A., et al. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2867835 · Cited by 166
3D Printed “Earable” Smart Devices for Real-Time Detection of Core Body Temperature
Ota, H., Chao, M., Gao, Y., Wu, E., Tai, L.-C., Chen, K., Matsuoka, Y., Iwai, K., Fahad, H. M., Gao, W., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00247 · Cited by 154
High Force Density Textile Electrostatic Clutch
Hinchet, R., & Shea, H. (2020) · Advanced Materials Technologies · doi:10.1002/admt.201900895 · Cited by 132
Baldi, T. L., Scheggi, S., Meli, L., Mohammadi, M., & Prattichizzo, D. (2017) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2017.2720667 · Cited by 96
Self-citationCapstanCrunch: A Haptic VR Controller with User-supplied Force Feedback
Sinclair, M., Ofek, E., Gonzalez-Franco, M., & Holz, C. (2019) · Proceedings of the 32nd Annual ACM Symposium on User Interface Software and Technology · doi:10.1145/3332165.3347891 · Cited by 95
“Wearable haptic feedback The most basic wearable haptic devices are finger-mounted actuators that render touch and pin-based texture [12] and shear [38] effects onto the user’s fingertip.”
BackgroundThe sense of agency in emerging technologies for human–computer integration: A review
Cornelio, P., Haggard, P., Hornbaek, K., Georgiou, O., Bergström, J., Subramanian, S., & Obrist, M. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.949138 · Cited by 75
Metadata
- Authors
- Prattichizzo, D., Chinello, F., Pacchierotti, C., & Malvezzi, M.
- Venue
- IEEE Transactions on Haptics
- Published
- 2013-10
- Volume
- 6
- Issue
- 4
- Pages
- 506-516
- ISSN
- 1939-1412 (ISSN-L)
- OpenAlex
- W2030898082
- Cited by
- 292
- References
- 36
- FWCI
- 25.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.