An EMG-Controlled Robotic Hand Exoskeleton for Bilateral Rehabilitation
Open accessAbstract
This paper presents a novel electromyography (EMG)-driven hand exoskeleton for bilateral rehabilitation of grasping in stroke. The developed hand exoskeleton was designed with two distinctive features: (a) kinematics with intrinsic adaptability to patient's hand size, and (b) free-palm and free-fingertip design, preserving the residual sensory perceptual capability of touch during assistance in grasping of real objects. In the envisaged bilateral training strategy, the patient's non paretic hand acted as guidance for the paretic hand in grasping tasks. Grasping force exerted by the non paretic hand was estimated in real-time from EMG signals, and then replicated as robotic assistance for the paretic hand by means of the hand-exoskeleton. Estimation of the grasping force through EMG allowed to perform rehabilitation exercises with any, non sensorized, graspable objects. This paper presents the system design, development, and experimental evaluation. Experiments were performed within a group of six healthy subjects and two chronic stroke patients, executing robotic-assisted grasping tasks. Results related to performance in estimation and modulation of the robotic assistance, and to the outcomes of the pilot rehabilitation sessions with stroke patients, positively support validity of the proposed approach for application in stroke rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2010 Update: A Report From the American Heart Association
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R. J., Brown, T. M., Carnethon, M., Dai, S., De Simone, G., Ferguson, T. B., Ford, E., Furie, K., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192667 · Cited by 5,700 · cited 1×
“MOTOR impairment of upper limb function is one of the most common and challenging outcomes after stroke [1].”
Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R. J., Brown, T. M., Carnethon, M., Dai, S., De Simone, G., Ferguson, T. B., Ford, E., Furie, K., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192666 · Cited by 1,359
Buchanan, T. S., Lloyd, D. G., Manal, K., & Besier, T. F. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 941
Myoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
Whitall, J., Waller, S. M., Silver, K. H. C., & Macko, R. F. (2000) · Stroke · doi:10.1161/01.str.31.10.2390 · Cited by 621
Luft, A. R., McCombe-Waller, S., Whitall, J., Forrester, L. W., Macko, R., Sorkin, J. D., Schulz, J. B., Goldberg, A. P., & Hanley, D. F. (2004) · JAMA · doi:10.1001/jama.292.15.1853 · Cited by 578
Hesse, S., Schulte-Tigges, G., Konrad, M., Bardeleben, A., & Werner, C. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04954-7 · Cited by 489
Interjoint coordination during pointing movements is disrupted in spastic hemiparesis
Levin, M. F. (1996) · Brain · doi:10.1093/brain/119.1.281 · Cited by 477
Rehabilitation robotics: pilot trial of a spatial extension for MIT-Manus
Krebs, H. I., Ferraro, M., Buerger, S. P., Newbery, M. J., Makiyama, A., Sandmann, M., Lynch, D., Volpe, B. T., & Hogan, N. (2004) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-1-5 · Cited by 445
Robotic techniques for upper limb evaluation and rehabilitation of stroke patients
Colombo, R., Pisano, F., Micera, S., Mazzone, A., Delconte, C., Carrozza, M. C., Dario, P., & Minuco, G. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848352 · Cited by 399
Effect of Lesion Location on Upper Limb Motor Recovery After Stroke
Shelton, F. D. N. A. P., & Reding, M. J. (2001) · Stroke · doi:10.1161/01.str.32.1.107 · Cited by 372
Rehabilitation of arm function after stroke. Literature review
Oujamaa, L., Relave, I., Froger, J., Mottet, D., & Pelissier, J.-Y. (2009) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2008.10.003 · Cited by 350
Latash, M. L. (2008) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195333169.001.0001 · Cited by 309
Lucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253
Improving Hand Function in Chronic Stroke
Muellbacher, W., Richards, C., Ziemann, U., Wittenberg, G., Weltz, D., Boroojerdi, B., Cohen, L., & Hallett, M. (2002) · Archives of Neurology · doi:10.1001/archneur.59.8.1278 · Cited by 253
Bilateral arm training: Why and who benefits?
Waller, S. M., & Whitall, J. (2008) · NeuroRehabilitation · doi:10.3233/nre-2008-23104 · Cited by 253
Development and control of a hand exoskeleton for rehabilitation of hand injuries
Wege, A., & Hommel, G. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545506 · Cited by 221
Grip force adjustments evoked by load force perturbations of a grasped object
Cole, K. J., & Abbs, J. H. (1988) · Journal of Neurophysiology · doi:10.1152/jn.1988.60.4.1513 · Cited by 214
Fischer, H., Stubblefield, K., Kline, T., Luo, X., Kenyon, R., & Kamper, D. (2007) · Topics in Stroke Rehabilitation · doi:10.1310/b662-3140-7q20-2778 · Cited by 193
ARMin - Exoskeleton for Arm Therapy in Stroke Patients
Nef, T., Mihelj, M., Kiefer, G., Perndl, C., Muller, R., & Riener, R. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428408 · Cited by 192
Cauraugh, J. H., Lodha, N., Naik, S. K., & Summers, J. J. (2010) · Human Movement Science · doi:10.1016/j.humov.2009.09.004 · Cited by 170
A Force-Feedback Exoskeleton for Upper-Limb Rehabilitation in Virtual Reality
Frisoli, A., Salsedo, F., Bergamasco, M., Rossi, B., & Carboncini, M. C. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902959250 · Cited by 163
Self-citationDesign of High Performance MIPS Cryptography Processor Based on T-DES Algorithm
Singh, K. P., & Parmar, S. (2015) · arXiv (Cornell University) · doi:10.48550/arxiv.1503.03166 · Cited by 161
An Actuated Finger Exoskeleton for Hand Rehabilitation Following Stroke
Worsnopp, T., Peshkin, M. A., Colgate, J. E., & Kamper, D. G. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428530 · Cited by 146
Positive effects of robotic exoskeleton training of upper limb reaching movements after stroke
Frisoli, A., Procopio, C., Chisari, C., Creatini, I., Bonfiglio, L., Bergamasco, M., Rossi, B., & Carboncini, M. C. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-36 · Cited by 143
Self-citationMachines to support motor rehabilitation after stroke: 10 years of experience in Berlin
Hesse, S., Schmidt, H., & Werner, C. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.02.0052 · Cited by 127
Reach & Grasp Therapy: Design and Control of a 9-DOF Robotic Neuro-rehabilitation System
Loureiro, R. C. V., & Harwin, W. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428510 · Cited by 123
A review of bilateral training for upper extremity hemiparesis
Stoykov, M. E., & Corcos, D. M. (2009) · Occupational Therapy International · doi:10.1002/oti.277 · Cited by 97
Song, R., & Tong, R. K. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344728 · Cited by 83
Powered upper limb prostheses : control, implementation and clinical application
Muzumdar, A. (2004) · Springer eBooks · Cited by 69
Waller, S. M., Harris-Love, M. L., Liu, W., & Whitall, J. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-0235-3 · Cited by 66
An Assessment of Robot-Assisted Bimanual Movements on Upper Limb Motor Coordination Following Stroke
Lewis, G. N., & Perreault, E. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2029315 · Cited by 60
Powell, L., Parker, J., James, M. M., & Mawson, S. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.5891 · Cited by 59
Motion Coordination Patterns During Cylinder Grip Analyzed With a Sensor Glove
Gülke, J., Wachter, N. J., Geyer, T., Schöll, H., Apic, G., & Mentzel, M. (2010) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2009.12.031 · Cited by 40
Knutson, J. S., Harley, M. Y., Hisel, T. Z., Makowski, N. S., & Chae, J. (2014) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000000066 · Cited by 20
Fuzzy Logic and Probabilistic Neural Network for EMG Classification - A Comparitive Study
George, K., Sivanandan, K. S., & Mohandas, K. P. (2012) · Cited by 13
Bimanual Haptic-desktop platform for upper-limb post-stroke rehabilitation: Practical trials
Li, S., Frisoli, A., Avizzano, C. A., Ruffaldi, E., Lugo–Villeda, L. I., & Bergamasco, M. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.5420694 · Cited by 13
Self-citation
Cited by
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Self-citationA Review on Design of Upper Limb Exoskeletons
Gull, M. A., Bai, S., & Bak, T. (2020) · Robotics · doi:10.3390/robotics9010016 · Cited by 435
Emerging Wearable Interfaces and Algorithms for Hand Gesture Recognition: A Survey
Jiang, S., Kang, P., Song, X., Lo, B., & Shull, P. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3078190 · Cited by 270
Song, X., van de Ven, S. S., Chen, S., Kang, P., Gao, Q., Jia, J., & Shull, P. B. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.811950 · Cited by 47
“, 2017), but only healthy subjects were included, or the motion of each patient’s unaffected side was included to perform bilateral training (Leonardis et al., 2015), (Lipovsky and Ferreira, 2015).”
Background
Metadata
- Authors
- Leonardis, D., Chisari, C., Bergamasco, M., Frisoli, A., Barsotti, M., Loconsole, C., Solazzi, M., Troncossi, M., Mazzotti, C., Castelli, V. P., Procopio, C., & Lamola, G.
- Venue
- IEEE Transactions on Haptics
- Published
- 2015-04-01
- Volume
- 8
- Issue
- 2
- Pages
- 140-151
- ISSN
- 1939-1412 (ISSN-L)
- 2329-4051
- 2334-0134
- OpenAlex
- W2066459718
- Cited by
- 339
- References
- 38
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.