An Accurate Power Control Strategy for Power-Electronics-Interfaced Distributed Generation Units Operating in a Low-Voltage Multibus Microgrid
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
In this paper, a power control strategy is proposed for a low-voltage microgrid, where the mainly resistive line impedance, the unequal impedance among distributed generation (DG) units, and the microgrid load locations make the conventional frequency and voltage droop method unpractical. The proposed power control strategy contains a virtual inductor at the interfacing inverter output and an accurate power control and sharing algorithm with consideration of both impedance voltage drop effect and DG local load effect. Specifically, the virtual inductance can effectively prevent the coupling between the real and reactive powers by introducing a predominantly inductive impedance even in a low-voltage network with resistive line impedances. On the other hand, based on the predominantly inductive impedance, the proposed accurate reactive power sharing algorithm functions by estimating the impedance voltage drops and significantly improves the reactive power control and sharing accuracy. Finally, considering the different locations of loads in a multibus microgrid, the reactive power control accuracy is further improved by employing an online estimated reactive power offset to compensate the effects of DG local load power demands. The proposed power control strategy has been tested in simulation and experimentally on a low-voltage microgrid prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Stationary frame current regulation of PWM inverters with zero steady-state error
Zmood, D. N., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810852 · Cited by 1,518
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733
Design, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Self-citationControl of Distributed Generation Systems— Part II: Load Sharing Control
Marwali, M. N., Jung, J.-W., & Keyhani, A. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836634 · Cited by 438
Real-World MicroGrids-An Overview
Barnes, M., Kondoh, J., Asano, H., Oyarzabal, J., Ventakaramanan, G., Lasseter, R., Hatziargyriou, N., & Green, T. (2007) · 2007 IEEE International Conference on System of Systems Engineering · doi:10.1109/sysose.2007.4304255 · Cited by 364
Microgrid Power Quality Enhancement Using a Three-Phase Four-Wire Grid-Interfacing Compensator
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.858262 · Cited by 346
Self-citationPower Flow Control of a Single Distributed Generation Unit
Dai, M., Marwali, M. N., Jung, J., & Keyhani, A. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911815 · Cited by 136
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“To overcome the issues of power sharing inaccuracy and active/reactive power coupling in distribution networks, the control loop is augmented with a virtual inductive output impedance in [79], [84], [85].”
BackgroundMethodGuerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
AC-microgrids versus DC-microgrids with distributed energy resources: A review
Justo, J. J., Mwasilu, F., Lee, J., & Jung, J.-W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.067 · Cited by 1,245
Metadata
- Authors
- Li, Y. W., & Kao, C.-N.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2009-12
- Volume
- 24
- Issue
- 12
- Pages
- 2977-2988
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2139033201
- Cited by
- 1,127
- References
- 17
- FWCI
- 94.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.