Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Abstract
In this paper, a two-level fault-tolerant voltage source inverter (VSI) for permanent magnet drives is systematically designed and tested. A standard two-level inverter consists of three legs. In this case of fault-tolerant inverter, a redundant leg is added that replaces the faulted leg. Faulted leg isolation and redundant leg insertion are done by using independent back-to-back-connected thyristors. The proposed inverter provides tolerance to both short-circuit and open-circuit faults of the switching devices. The postfault performance is the same as the normal prefault operation and fault compensation is fast enough such that there is negligible disturbance in the drive operation. The fault tolerance of the inverter is verified using field-oriented control of a permanent magnet synchronous motor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“According to [238], [239], power semiconductor device damages account for approximately 35% of all ASD faults.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [239]
In the citing paper
“Recently, phase redundancy approaches [239], [309] have gained popularity due to their full fault recovery without oversizing the drive.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [239]
Citations
Cites
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724 · cited 1×
“Several fault-tolerant topologies are available in the literature [5]; some of them reconfigure the standard inverter topology and reformulate the current references so that the rotating”
BackgroundFault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 2×
“According to [14], the open-circuit fault of the IGBT can be detected by inserting voltage sensors at desired locations.”
BackgroundMethodInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
A strategy for improving reliability of field-oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.245714 · Cited by 374 · cited 1×
“faulted leg has to be connected to the midpoint of the dc voltage link, created using the use of two capacitors [6].”
MethodInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370 · cited 3×
“Moreover, the current dc component generates unequal current stress in the upper and lower transistors in the inverter, which may cause thermal defects in the transistors [1].”
BackgroundInfluentialFault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304 · cited 2×
“[15] suggested the open switch fault detection by analyzing the current vector trajectory and of the instantaneous frequency in the faulty mode.”
BackgroundMethodFault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299 · cited 1×
“A simplified version of [7] has been developed in [8], where only fast-acting semiconductor fuses are used to isolate”
BackgroundFuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270 · cited 1×
“IGBT are available in the literature [13]–[16].”
Research works printed but not linked: 2
- schwab, 2003, Reliability evaluation of a permanent magnet synchronous motor drive for an automotive application, Proc Eur Conf Power Electron Appl
- thorsen, 1995, A survey of the reliability with an analysis of faults on the variable frequency drives in industry, Proc Conf Rec 6th Eur Power Electron Appl Conf, 1033
Cited by
Items 101–200 of 283
Open-Circuit Fault Analysis and Diagnosis for Indirect Matrix Converter
Shi, B., Zhou, B., Zhu, Y., Qin, X., Lei, J., & Han, N. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2772788 · Cited by 19
“2772788 failure detection is of great concern to ensure the reliability of power electronic equipment [10], [11].”
BackgroundAnalytical optimal currents for multiphase PMSMs under fault conditions and saturation
Nguyen, N. K., Flieller, D., Kestelyn, X., Moraes, T. J. D. S., & Semail, E. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7048968 · Cited by 18
“On the other hand, only a few works have addressed the problem of inverter switch short-circuit faults [9], except in topologies with additional components such as fuses and parallel thyristors which are not used in healthy operation [10, 11].”
Design and control of fault-tolerant permanent magnet machines
Mohammadpour, A., Gandhi, A., & Parsa, L. (2013) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2013.6525171 · Cited by 17
Zhao, W., Gu, C., Chen, Q., Ji, J., & Xu, D. (2017) · CES Transactions on Electrical Machines and Systems · doi:10.23919/tems.2017.7911112 · Cited by 17
Open Phase Fault Tolerant Control of Multi Three Phase Machines
Harikumaran, J., Buticchi, G., Galea, M., & Wheeler, P. (2021) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2021.3115404 · Cited by 17
Kontarček, A., Nemec, M., Bajec, P., & Ambrozic, V. (2014) · Automatika · doi:10.7305/automatika.2014.12.624 · Cited by 16
“Hardware solutions with additional phase or neutral leg topologies are presented in [16, 28-30].”
BackgroundXu, Y., Yan, H., & Zou, J. (2015) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2015.2413897 · Cited by 16
Fault Tolerant Control of a Brushless DC Motor with Defective Position Sensors
Papathanasopoulos, D. A., & Mitronikas, E. D. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8507013 · Cited by 15
“It is well known that, an electric motor drive system is affected by potential motor faults [1], power electronics converter faults [2], and sensor faults [3].”
BackgroundAleem, Z., Winberg, S. L., Ahmed, H. F., & Park, J.-W. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3098685 · Cited by 15
“2) Dead time is required in the inverter bridge switches of VSIs to avoid the short circuit of input capacitor, while overlap time is required in CSIs to provide continuous current path for the input inductor [4], [5].”
BackgroundReliability evaluation of a novel fault tolerant multilevel inverter with reduced components
Dewangan, N. K., Verma, D., Agrawal, R., Kumar, D., & Gupta, K. K. (2023) · Electrical Engineering · doi:10.1007/s00202-023-01744-3 · Cited by 15
“The main reason behind overall inverter failure is the failure of active power semiconductor devices, drivers, and sources [7, 8].”
BackgroundChérif, B. D. E., Bendjebbar, M., Benouzza, N., Boudinar, H., & Bendiabdellah, A. (2016) · International Conference on Modelling, Identification and Control · doi:10.1109/icmic.2016.7857513 · Cited by 15
Online Current Optimization Based Fault-Tolerant Control of Standard PMSM Drives
Zhang, Y., Chen, X., Wang, X., Zhang, T., Wang, Z., & Mao, Y. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3398673 · Cited by 14
“Moreover, the three-phase motor can attain better FT performance by connecting a four-leg VSI to the neutral point of the three-phase motor [11], [12].”
BackgroundAutomatic Voltage Stabilization Using IGBT Based on Load Tap Changer With Fault Consideration
Ismail, A. A. A., Alsuwaidi, H., & Elnady, A. (2021) · IEEE Access · doi:10.1109/access.2021.3079507 · Cited by 15
“In drive system utilizing IGBT switches, the authors in [23]–[26] have reported that around 38% of the faults are due to power devices.”
BackgroundZhang, X., Gauthier, J.-Y., & Lin-Shi, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3048070 · Cited by 14
“To be specific, if the fault occurs in inverter legs, remedial strategies can be achieved by moving the motor terminal of the faulty leg to the midpoint of split capacitors or to an auxiliary inverter leg via triode for alternating current (TRIACs) [11].”
BackgroundPatnana, H. K., & Somasekhar, V. T. (2021) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3048 · Cited by 13
Review of Fault Tolerant Multi-Motor Drive Topologies for Automotive Applications
Sakka, M. A., Geury, T., Baghdadi, M. E., Dhaens, M., Sakka, M. A., & Hegazy, O. (2022) · Energies · doi:10.3390/en15155529 · Cited by 13
Fault tolerant operation of a five phase converter for PMSM drives
Salehifar, M., Arashloo, R. S., Moreno‐Eguilaz, M., Sala, V., & Romeral, L. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520448 · Cited by 13
“A two level fault tolerant voltage source inverter (VSI) which protects both switch short circuit and open circuit faults is presented at [15].”
BackgroundComparison of fault tolerant control algorithm using space vector modulation of PMSM drive
Łuczak, D., & Siembab, K. (2014) · International Conference on Mechatronics - Mechatronika · doi:10.1109/mechatronika.2014.7018231 · Cited by 13
“The topology modifications involve the use of redundant branches transistor bridge, which requires a substantial expansion of the standard topology [1] or bypassing of the damaged leg or phase of the motor inverter by connecting it to zero voltage mid-point of supply.”
BackgroundA survey of cascaded multi-level PWM rectifier with VIENNA modules for HVDC system
Jiang, X., Yang, J., Han, J., & Tang, T. (2014) · IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac.2014.7037831 · Cited by 13
Quasi-Clamped ZSI With Two Transformers
Aleem, Z., Yang, H.-K., Ahmed, H. F., & Park, J.-W. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3028797 · Cited by 13
A Fault-Tolerant Switching Scheme for an Isolated DC/AC Matrix Converter
Tajfar, A., & Mazumder, S. K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2360706 · Cited by 12
“As such, the need for fault-tolerant operation, which has become almost a mandatory requirement in power converters for military and aeronautical applications, is gaining traction for commercial applications as well.”
BackgroundMeyyappan, C., & Ravichandran, C. S. (2022) · Solar Energy · doi:10.1016/j.solener.2022.08.015 · Cited by 12
Zhou, D., Zhao, J., & Liu, Y. (2016) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2016.7525812 · Cited by 15
Estima, J. O., & Cardoso, A. J. M. (2012) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2012.6350221 · Cited by 12
Marine propulsion PM motor control under inverter partial fault
Fernando, N., Jayasinghe, S. G., & Abkenar, A. T. (2016) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec.2016.7846210 · Cited by 11
“The technique proposed in [23], [24] involves a fourth inverter leg for control and mechanisms for the disconnection of the faulty leg.”
MethodPerformance Analysis of Fault-Tolerance Techniques Towards Solar Fed Cascaded Multilevel Inverter
Meyyappan, C., & Ravichandran, C. S. (2021) · International Conference on Computer Communication and Informatics (ICCCI) · doi:10.1109/iccci50826.2021.9402705 · Cited by 13
“In 2015 [28] the same reductant switching has experimented with 5 level inverters with single phase inverter has been used.”
MethodIterative learning control for fault-tolerance in multi-phase permanent-magnet machines
Mohammadpour, A., Mishra, S., & Parsa, L. (2013) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2013.6580768 · Cited by 11
“Extensive research work has been reported on fault-tolerant operation of conventional three-phase motor drives under open-circuit faults conditions [1], [2].”
BackgroundA fault tolerant control and power electronic for a permanent magnet synchronous motor drive
Errabelli, R. R., & Mutschler, P. (2011) · European Conference on Power Electronics and Applications · Cited by 10
Self-citationDesign and Implementation of Single Phase Inverter Based on Cuk Converter for PV System
(2017) · International Journal of Renewable Energy Research · doi:10.20508/ijrer.v7i2.5452.g7033 · Cited by 10
“Since, the instantaneous value of average output voltage of the VSI at any instant is consistently lesser than the dc source voltage, a dc-dc boost converter is recommended [2].”
BackgroundReliability Assessment of a Fault-Tolerant PV Multistring Inverter
Renaudineau, H., Paradell, P., Trilla, L., Filbà-Martínez, À., Cardoner, D., & Domínguez‐García, J. L. (2020) · Energies · doi:10.3390/en13246525 · Cited by 10
“Leg-redundant fault-tolerant solutions have been largely proposed in the case of three-phase inverters [11,12] and single-phase DC-AC converters [13].”
BackgroundAbdennadher, I., & Masmoudi, A. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2445818 · Cited by 10
“The concept proposed in [20] has been extended in [21], where a fault-tolerant dual PM traction module for subway application has been proposed.”
BackgroundRobust digital deadbeat control design technique for 3 phase VSI with disturbance observer
Chauhdary, S. T., Wang, J., Kaloi, G. S., & Baloch, M. H. (2017) · IEICE Electronics Express · doi:10.1587/elex.14.20170351 · Cited by 10
“VSIs have several applications in power electronics motor drives [5], distributed generation systems [6], uninterruptable power supply system [2, 7] and © IEICE 2017 DOI: 10.”
BackgroundMahdhi, H. B., Azza, H. B., & Jemli, M. (2020) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12436 · Cited by 10
IGBT open-circuit fault detection for voltage source inverters using DC bus magnetic field signal
Vu, H., & Yahoui, H. (2021) · Electrical Engineering · doi:10.1007/s00202-020-01161-w · Cited by 10
The enhancement of park current vectors technique for inverter fault detection
Chérif, B. D. E., Azzeddine, B., Amine, K. M., Bendjebbar, M., & Benouzza, N. (2017) · International Conference on Systems and Control (ICSC) · doi:10.1109/icosc.2017.7958646 · Cited by 10
BLDC motor drive controller for electric vehicles
Tashakori Abkenar, A. (2014) · Swinburne figshare (Swinburne University of Technology) · doi:10.25916/sut.26284936 · Cited by 10
Fault-Tolerant Control of Common Electrical Faults and Sensor Faults in Sensorless PMSM Drives
Zhang, Y., Wang, X., Kong, L., Lu, L., Wang, Z., & Mao, Y. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3574040 · Cited by 9
Inverter Switch Fault Diagnosis System for BLDC Motor Drives
Abkenar, A. T., & Ektesabi, M. (2014) · Engineering letters · Cited by 9
New enhanced performance robust control design scheme for grid-connected VSI
Syed, A. H., & Abido, M. A. (2016) · Control Engineering Practice · doi:10.1016/j.conengprac.2016.04.007 · Cited by 9
Fault Diagnosis and Reconfiguration of Multilevel Inverter Switch Failure-A Performance Perspective
Manjunath, T. G., & Kusagur, A. (2016) · International Journal of Electrical and Computer Engineering (IJECE) · doi:10.11591/ijece.v6i6.pp2610-2620 · Cited by 9
Shuai, Y., Jiang, D., Hu, F., Zhou, M., & Liu, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3309415 · Cited by 9
“Besides AMB system, many scholars have studied the corresponding fault detection and tolerance in many areas, such as multilevel converters system [7], voltage source inverter for permanent magnet drives [8], and motor drives for multiphase motors [9].”
BackgroundInnovative thermal model for the estimation of permanent magnet and stator winding temperatures
Kral, C., Haumer, A., & Lee, S. B. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342386 · Cited by 9
“T e p = T e p [1] + T e p [2] + T e p [3] + T e p [4] + T e p [5]”
Hicham, F., Yousfi, D., Elhafyani, M. L., & Driss, Y. A. (2017) · Information · doi:10.3390/info8010011 · Cited by 9
“This strategy is the interest of authors in [3-11].”
BackgroundInverter open circuit faults diagnosis in series-connected six-phases permanent magnet drive
Moraes, T. J. D. S., Trabelsi, M., Nguyen, N. K., Semail, E., Meinguet, F., & Guerin, M. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062354 · Cited by 9
“The replacement of a faulty transistor is simply implemented, but it demands redundant components and TRIACs in order to isolate the faulty transistor and connect the healthy one to the system, increasing thus the system cost [8].”
Sensor-fault tolerant control of PMSM in flux-weakening operation using LKF observer
Máthé, L., Kopacz, C., Bede, L., & Rasmussen, P. O. (2012) · IEEE International Conference on Electrical Systems for Aircraft, Railway, Ship Propulsion and Road Vehicles & International Transportation Electrification Conference (ESARS-ITEC) · doi:10.1109/esars.2012.6387427 · Cited by 9
Manjunath, T. G., & Kusagur, A. (2015) · IEEE International Conference on Condition Assessment Techniques in Electrical Systems (CATCON) · doi:10.1109/catcon.2015.7449507 · Cited by 9
Fadil, H., Yousfi, D., Elhafyani, M. L., Driss, Y. A., & Nasrudin, A. R. (2016) · International Conference on Electrical Sciences and Technologies in Maghreb · doi:10.1109/cistem.2016.8066794 · Cited by 9
Detection of a two-level inverter open-circuit fault using the discrete wavelet transforms technique
Chérif, B. D. E., Azzeddine, B., & Bendjebbar, M. (2018) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2018.8352206 · Cited by 9
Tian, W., Wang, W., Hua, W., & Cheng, M. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3303433 · Cited by 8
“According to [10], the open-circuit fault (OCF) is one of the common faults in the drive system and open-circuit accounts for up to 38%.”
BackgroundA new fault-tolerant control strategy for switch open-circuit fault in open-winding driving system
Cui, R., Fan, Y. J., Zhang, X., Zhu, W., & Cheng, M. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793131 · Cited by 8
“The traditional two-level fault-tolerant control strategy is described in [6-7].”
BackgroundFault tolerant capability of deadbeat — Direct torque and flux control for three-phase PMSM drives
Pulvirenti, M., Scarcella, G., Scelba, G., & Lorenz, R. D. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855113 · Cited by 9
“Some power converter topologies are able to tolerate a single open/short circuit of power devices and an open circuit of the machine phases [12], [20], [22].”
BackgroundPower switch and current sensor fault-tolerant control of PMSG drives for wind turbine systems
Jlassi, I., Khil, S. K. E., & Bellaaj, N. M. (2015) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2015.7303721 · Cited by 8
“Various fault-tolerant voltage source inverters have been proposed by using a redundant leg connected to all the inverter phases through TRIACs [11], [12] or by connecting the midpoint of the dc bus to the inverter phases [13], [14].”
MethodInfluentialThree-Level Inverter Fault Detection and Diagnosis Using Current-Based Statistical Analysis
Baghli, M., Delpha, C., Diallo, D., & Hallouche, A. (2018) · Prognostics and System Health Management Conference · doi:10.1109/phm-chongqing.2018.00123 · Cited by 8
Moraes, T. J. D. S., Nguyen, N. K., Meinguet, F., & Semail, E. (2015) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2015.7281694 · Cited by 7
Zhu, Z. Q., Pothi, N., Xu, P. L., & Ren, Y. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506841 · Cited by 7
Khan, S. N., Khan, A. A., Jamil, M., Khan, U. A., Ahmed, H. F., & Ahmed, S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3360309 · Cited by 7
Fault-Tolerant Control of Open-Circuit Fault for Permanent Magnet Starter/Generator
Huang, J., Zhang, Z., & Jiang, W. (2018) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems.2018.8549174 · Cited by 7
“In [8], the faulted leg is replaced by a redundant leg instead of connecting to the neutral point of the PMM.”
BackgroundPost‐fault operation strategy for single open‐phase fault in three‐phase induction motor drives
Abbasi, H., Ghanbari, M., Ebrahimi, R., & Jannati, M. (2022) · IET Power Electronics · doi:10.1049/pel2.12300 · Cited by 7
Fault tolerant control of a double stator permanent magnet generator in tidal current energy system
Zhang, J., Houari, A., Seck, A. B., Moreau, L., & Machmoum, M. (2016) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2016.7474789 · Cited by 7
A-source Inverter-fed PMSM drive with fault-tolerant capability for Electric Vehicles
Sharma, V., Mukhopadhyay, S. C., Hossain, M. J., Ali, S. M. N., & Kashif, M. (2020) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie45063.2020.9152411 · Cited by 7
“Several literature proposed the faulttolerant remedies for ac motors [8], [9] and permanent magnet synchronous motor (PMSM) drives [10]–[12].”
BackgroundOptimized Filter Design for Common-Mode Current Reduction in Four-Wire Inverter-Fed Motors
Zhao, Z., Horn, B., & Leidhold, R. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3066936 · Cited by 7
Fault-tolerant converter for AC drives using vector-based hysteresis current control
Freire, N. M. A., & Cardoso, A. J. M. (2013) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2013.6645724 · Cited by 7
Fault tolerant control of permanent magnet synchronous motor traction module
Moujahed, M., Hajji, M., Azza, H. B., Jemli, M., & Boussak, M. (2018) · International Renewable Energy Congress · doi:10.1109/irec.2018.8362501 · Cited by 6
Geng, C., Wang, T., Tang, T., Benbouzid, M., & Qin, H. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512390 · Cited by 7
“To deal with the fault in traditional inverter, Switch-redundant topologies [12], neutral leg topologies [13], additional phase leg topologies [14] and cascaded inverter topology [15] have been studied.”
MethodQiu, L., Peng, Q., Yang, Y., Xu, W., & Liang, Q. (2017) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2017.8028480 · Cited by 6
Moujahed, M., Touaiti, B., Azza, H. B., Jemli, M., & Boussak, M. (2018) · International Journal of Power Electronics and Drive Systems (IJPEDS) · doi:10.11591/ijpeds.v9.i2.pp579-590 · Cited by 6
Manikandan, R., Singh, R. R., Edison, G., & Gnanaraj, S. D. (2021) · Engergy systems in electrical engineering · doi:10.1007/978-981-16-4388-0_14 · Cited by 6
Adding inverter fault detection to model-based predictive control for flying-capacitor inverters
Druant, J., Vyncke, T. J., & Melkebeek, J. A. A. (2013) · IEEE International Symposium on Sensorless Control for Electrical Drives (SLED) · doi:10.1109/sled-precede.2013.6684498 · Cited by 7
Review on VSI switch fault tolerant control systems for electric vehicle drivetrains
Tashakori Abkenar, A. (2024) · Engineering letters · doi:10.25916/sut.26223590 · Cited by 6
Harmonic Current Suppression for Open-Ending Winding PMSM Based on Voltage Injection
Jiang, C., Zhang, H., Liu, H., Li, D., & Chen, D. (2025) · IEEE Access · doi:10.1109/access.2025.3545663 · Cited by 5
“Besides, the control freedoms and fault tolerant capability are also increased by the dual inverter structure [4], [5].”
Lee, K., Son, Y.-K., & Ha, J.-I. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512575 · Cited by 5
“In [10], a redundant-leg scheme was proposed.”
BackgroundNewly fault-tolerant indirect vector control for traction inverter
Zerdani, S., Elhafyani, M. L., Fadil, H., & Zouggar, S. (2021) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v12.i3.pp1576-1585 · Cited by 5
Active fault tolerant control for Permanent Magnet Synchronous Motor drives
Zerdani, S., Elhafyani, M. L., FADIL, H., & Zouggar, I. (2019) · International Conference of Computer Science and Renewable Energies (ICCSRE) · doi:10.1109/iccsre.2019.8807463 · Cited by 5
Lin, H., Li, W., Hu, B., Chen, J., Li, J., & Zhao, F. (2019) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8921688 · Cited by 5
“Therefore, the ability of keeping the multi-drive system continuous operation and improved reliability of the system are particularly important [1].”
BackgroundBhakar, P. S., Kalaiselvi, J., Gorla, N. B. Y., & Pou, J. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3395796 · Cited by 5
“Table V shows a comparison between proposed topology and the existing fault-tolerant topologies in the literature [6], [29], [30] on basis of the topology description, additional hardware used, fault type, and number of devices in current path in case of healthy and post-fault conditions.”
BackgroundOpen-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power Generation System
Das, P. S., & Kim, K. (2015) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v6.i2.pp293-304 · Cited by 5
“A two-level fault-tolerant voltage source inverter for permanent magnet drive has been proposed [9], which provides tolerance to both short-switch and open-switch faults of the switching devices.”
BackgroundFreire, N. M. A., & Cardoso, A. J. M. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520700 · Cited by 5
Modified space vector modulation for fault tolerant control of PMSM drive
Siembab, K., & Zawirski, K. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/epepemc.2016.7752142 · Cited by 5
“These changes are related with the unbalance of the motor phases [1], [2], [3].”
BackgroundKumar, V., & Fernandes, B. G. (2017) · IET Power Electronics · doi:10.1049/iet-pel.2017.0202 · Cited by 5
Gleißner, M., Häring, J., Wondrak, W., & Bakran, M. (2019) · European Conference on Power Electronics and Applications · doi:10.23919/epe.2019.8914957 · Cited by 5
“An example is the B6 inverter with an additional fourth phase that can replace the failed phase [1–6].”
Detection and Compensation of Transistor and Position Sensors Faults in PM BLDCM Drives
Skóra, M., & Kowalski, C. T. (2016) · Studies in systems, decision and control · doi:10.1007/978-3-319-45735-2_9 · Cited by 5
Switched Capacitor Inverter with Reduced Inrush Current and High Boosting Gain
Choudhary, A., Singh, A. K., Mandal, R. K., & Saha, A. K. (2024) · Energies · doi:10.3390/en17133064 · Cited by 4
Chérif, B. D. E., Djerioui, A., Zeghlache, S., Seninete, S., & Tamer, A. (2020) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12540 · Cited by 4
Extension of the FundamentalWave Library towards Multi Phase Electric Machine Models
Kral, C., Haumer, A., & Woehrnschimmel, R. (2014) · Linköping electronic conference proceedings · doi:10.3384/ecp14096135 · Cited by 4
Fault‐tolerant control for a dual‐PMSM drive system
Tseng, S., Liu, T., Hsu, J., Ramelan, L. R., & Firmansyah, E. (2016) · The Journal of Engineering · doi:10.1049/joe.2016.0092 · Cited by 4
A review on fault-tolerant control of PMSM
Wangguang, Wang, Z., Wang, D., Li, Y., & Li, M. (2017) · Chinese Automation Congress · doi:10.1109/cac.2017.8243452 · Cited by 6
Xu, Q., Zhan, J., Xiao, L., & Chen, G. (2018) · Frontiers of Information Technology & Electronic Engineering · doi:10.1631/fitee.1601296 · Cited by 4
A Novel Fault-Tolerant Control Technique for an Inverter With Hysteresis Current
Li, K., Chen, C., Cheng, S., Yu, T., Xiang, C., & Wu, X. (2018) · Computing in Science & Engineering · doi:10.1109/mcse.2018.2886194 · Cited by 4
“iL t ð Þ 1⁄4 De t t (4) where D is the integration constant, which is determined by the initial conditions.”
BackgroundRajan, V. R., & Premalatha, L. (2020) · GAZI UNIVERSITY JOURNAL OF SCIENCE · doi:10.35378/gujs.559127 · Cited by 4
“VSIs can implement only buck operation while CSIs can perform only voltage boost inversion [1].”
MethodCaseiro, L. M. A., & Mendes, A. M. S. (2021) · Energies · doi:10.3390/en14082210 · Cited by 5
A Novel High-Frequency Isolated Single-Phase Full-Bridge Buck-Boost inverter
Khan, U. A., Khan, A. A., Akbar, F., & Park, J.-W. (2021) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon48115.2021.9589949 · Cited by 4
“INTRODUCTION The power inverters are mainly classified as voltage source or current source inverters [1-2].”
BackgroundKumar, P. H., Lakhimsetty, S., & Somasekhar, V. T. (2023) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3642 · Cited by 4
Fault-tolerant strategy of dual PWM converter in wind power system
Shen, Y., Wu, J., Zhou, W., & Zhao, Z. (2015) · IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems · doi:10.1109/cyber.2015.7288047 · Cited by 4
“The concept of fault tolerance [5, 6] was formally proposed in the seminar on control held in the United Santa Clara University in the 1980s.”
BackgroundSliding mode controller in fault tolerant PMSM drive
Bendjedia, B., Bouchafaa, F., Aliouane, K., & Aissani, M. (2013) · International Conference on Power Engineering, Energy and Electrical Drives · doi:10.1109/powereng.2013.6635577 · Cited by 4
Fault tolerance analysis for the 5-level unidirectional T-Rectifier
Lidozzi, A., Benedetto, M. D., Solero, L., Crescimbini, F., & Grbović, P. J. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855112 · Cited by 4
“Even in multilevel topologies, continuous operation after a fault condition is accomplished using additional components [10], such as fuses, SCRs and supplementary phase-legs; resulting in an increased system cost and configuration complexity.”
BackgroundJin, S. J., Shi, L. X., Zhang, Y., Sun, D., & Ji, B. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12055 · Cited by 4
A highly reliable and efficient differential type buck-boost DC-AC converter
Akbar, F., Cha, H., Khan, A. A., & Kim, H.-G. (2017) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec.2017.7992319 · Cited by 3
“The most frequently used inverter is voltage source inverter [1], but it can perform only buck function.”
MethodCurrent Regulation in Case of Open Circuit Fault for Six-phase Traction Open-end Winding Machine
Stolyarov, E., Ali, Y., Lashkevich, M., Fedorova, K., Kulik, E., & Anuchin, A. (2023) · International Conference on Electromechanical and Energy Systems (SIELMEN) · doi:10.1109/sielmen59038.2023.10290786 · Cited by 3
“Some of them should be handled by the hardware [14].”
BackgroundMPC based fault tolerance control of AC–DC power converters for offshore wind turbines
Shi, Y., Feng, Y., Ren, M., & Qiu, Y. (2024) · Journal of Power Electronics · doi:10.1007/s43236-024-00914-1 · Cited by 3
“For topology redundancy FTC approaches, redundant hardware components, such as switches [6], legs [7], and systems [8], are employed to replace the faulty switches and restore the sys-tem from fault conditions.”
PI and sliding mode controllers in fault tolerant PMSM drive
Bendjedia, B., Bouchafaa, F., Aissani, M., & Aliouane, K. (2015) · International Conference on Control, Engineering & Information Technology · doi:10.1109/ceit.2015.7233016 · Cited by 3
Metadata
- Authors
- Errabelli, R. R., & Mutschler, P.
- Affiliations
- Technische Universität Darmstadt (DE)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-02
- Volume
- 27
- Issue
- 2
- Pages
- 500-508
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2079590925
- Cited by
- 278
- References
- 19
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 10 · 2023: 10 · 2022: 17 · 2021: 25 · 2020: 19 · 2019: 23 · 2018: 25 · 2017: 25 · 2016: 22 · 2015: 23 · 2014: 29 · 2013: 24 · 2012: 13
- FWCI
- 15.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- fault-tolerant inverter, voltage source inverter, permanent magnet synchronous motor, short-circuit faults, open-circuit fault, field-oriented control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.