CoChat

Wind Turbine Generator–Battery Energy Storage Utility Interface Converter Topology With Medium-Frequency Transformer Link

Krishnamoorthy, Harish S., Rana, Dibyendu, Garg, Pawan, Enjeti, Prasad N., Pitel, Ira J. · 2014 · IEEE Transactions on Power Electronics

The DOI matches its Crossref record; 25 of the 26 references it cites were found in a registry or an index.

Abstract

A medium-voltage (MV) wind turbine generator (WTG)-battery energy storage (BESS) grid interface converter topology with medium-frequency (MF) transformer isolation is introduced in this paper. The system forms a three-port network in which several series stacked ac-ac converters transform the low-frequency (50/60 Hz) utility MV into MF (0.4 to 2 kHz) ac voltage by modulating it with MF square wave. This voltage is then fed to the MF transformer primary windings. The secondary and tertiary windings interface with the WTG side and the BESS side, respectively, after power conversion. The power generated by WTG is transferred to the MF transformer secondary windings through a three-phase pulse width modulation (PWM) rectifier and a three-phase PWM inverter, whereas the power transfer between the BESS and the tertiary winding occurs through a three-phase PWM inverter. It is shown that the utility grid sinusoidal currents, the battery current, and the WTG output currents can be controlled to be of good quality using PI and DQ control strategies. Thus, the proposed MF transformer-based three-port topology results in smaller converter weight/volume. Moreover, the control can handle voltage sags/swells and provide low voltage ride-through capability. Simulation waveforms along with experimental results are shown as proof of concept.

Overview

Integrity signals

Registry

Crossref · 10.1109/tpel.2013.2295419

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Cited by

See all 48

Metadata

Authors
Krishnamoorthy, H. S., Rana, D., Garg, P., Enjeti, P. N., & Pitel, I. J.
Affiliations
  • Texas A&M University (US)
  • Wilmington College (US)
Venue
IEEE Transactions on Power Electronics
Published
2014-08
Volume
29
Issue
8
Pages
4146-4155
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2056943204
Cited by
48
References
26
Citations by year
2025: 1 · 2024: 2 · 2023: 4 · 2022: 10 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 4 · 2017: 9 · 2016: 6 · 2015: 2 · 2014: 2
FWCI
3.37
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Electronics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
Keywords
wind turbine generator, battery energy storage, medium frequency transformer, PWM rectifier, PWM inverter, medium-voltage distribution networks, low-voltage ride-through, voltage sag and swell

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.