Design and Experimental Testing of a Resonant DC–DC Converter for Solid-State Transformers

Ortiz, Gabriel, Leibl, Michael Georg, Huber, Jonas Emanuel, Kolar, Johann Walter · 2017 · IEEE Transactions on Power Electronics

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

In the solid-state transformer (SST) concept, the key task of voltage adaptation and isolation is performed by a high-power dc-dc converter, which is operated in the medium-frequency range, hence enabling a reduction in size and weight of the converter's reactive components. This dc-dc converter presents the main challenge in the implementation of the SST concept, given its operation at medium frequency together with the direct connection to medium voltage. This combination demands the utilization of dc-dc converter topologies that are able to operate in the soft-switching mode, whereby, given that typically insulated-gate bipolar transistor switches are used as power devices, zero-current switching modulation schemes become highly attractive and often mandatory in order to achieve the targeted efficiency goals. This paper describes in detail the analysis and design of a 166-kW/20-kHz dc-dc converter of the series-resonant type, which results to be particularly interesting for high-power applications, given its tight input-to-output transfer characteristics and its capability to ensure soft-switching transitions of all semiconductor devices. The main focus of this paper is to describe in detail the practical implementation of the aforementioned resonant dc-dc converter, where its main components, i.e., the medium- and low-voltage-side power bridges and the medium-frequency transformer, are described independently. The assembled prototype is presented together with the implemented testing strategy and the final experimental results.

Overview

Integrity signals

Registry

Crossref · 10.1109/tpel.2016.2637827

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 3

  1. huber, 0, Volume/weight/cost comparison of 1MVA 10 kV/400 V solid-state and conventional low-frequency distribution network, Proc IEEE Energy Convers Congr Expo, 4545
  2. engel, 0, 15 kV/16.7 Hz energy supply system with medium frequency transformer and 6.5 KV IGBTS in resonant operation, Proc Eur Conf Power Electron Appl, 2
  3. lindenmuller, 0, Optimization of a series resonant DC/DC converter for traction applications, Proc IEEE Energy Convers Congr Expo, 2201

Cited by

See all 143

Metadata

Authors
Ortiz, G., Leibl, M. G., Huber, J. E., & Kolar, J. W.
Affiliations
ETH Zurich (CH)
Venue
IEEE Transactions on Power Electronics
Published
2017-10
Volume
32
Issue
10
Pages
7534-7542
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2560492545
Cited by
143
References
23
Citations by year
2026: 4 · 2025: 13 · 2024: 21 · 2023: 16 · 2022: 18 · 2021: 21 · 2020: 16 · 2019: 12 · 2018: 16 · 2017: 5
FWCI
5.23
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Electronics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
solid-state transformer, series resonant DC-DC converter, zero-current switching, soft switching, voltage isolation, IGBT, medium frequency transformer, converter design, high-power converters, prototype testing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.