High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC
Open accessThe DOI matches its Crossref record; 19 of the 21 references it cites were found in a registry or an index.
Abstract
This paper presents a high-frequency modular medium-voltage AC (4160 VAC or 13.8 kVAC) to low-voltage DC (400 VDC) system that is scalable in order to be used for different scale microgrids. A 15 kW, 500 kHz DC/DC converter is demonstrated as the most important stage of the system overall, which can be scalable to a 225 kW 4160 VAC to 400 VDC system. Motivation of a CLLC resonant converter and its design parameters determination is carefully illustrated. The high-frequency transformer is the key element for the DC/DC converter. Then, the paper focuses on high-frequency transformer design to realize high-voltage insulation, high efficiency, and high density at the same time. Based on a split winding UU core transformer structure, transformer insulation materials and dimension parameters are determined referring to the IEEE insulation standard. The transformer magnetic loss model is reviewed based on which loss design tradeoff is carefully analyzed. Different working frequency impact on transformer design over three different core materials is also presented. Finally, a 500 kHz transformer prototype has been developed and demonstrated with the IEEE standard required insulation tests. A whole CLLC resonant converter is also present with experiments results. The converter holds outstanding 98% efficiency and 2.9 kW/L power density.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642 · cited 1×
“To date, the cascaded H-bridge multilevel rectifier is deemed as a mature technology and can be directly applied to the proposed DC data center application [5].”
BackgroundOptimal choice for number of strands in a litz-wire transformer winding
Sullivan, C. R. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.750181 · Cited by 558
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478 · cited 7×
“Traditionally, the devices with the most use are high-voltage insulated gate bipolar transistors (IGBTs) [6], [7], [9], [10], [13], based on a three-level neutral point clamped (NPC) topology the 1.”
BackgroundMethodInfluentialEvaluation of 400V DC distribution in telco and data centers to improve energy efficiency
Pratt, A., Kumar, P., & Aldridge, T. V. (2007) · INTELEC 07 - 29th International Telecommunications Energy Conference · doi:10.1109/intlec.2007.4448733 · Cited by 415 · cited 1×
“Together, uninterruptible power system (UPS), power distribution unit (PDU), and power supply unit (PSU) will bring about a 21% loss of the total system power [2].”
BackgroundEdison Redux: 380 Vdc Brings Reliability and Efficiency to Sustainable Data Centers
AlLee, G., & Tschudi, W. (2012) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2012.2212607 · Cited by 273 · cited 1×
“In order to improve the power conversion efficiency inside the data center server hall, two approaches are proposed; one developing trend is to continue to use the AC distribution within the server hall with a paralleled UPS [3]; another approach is to, instead employ of the ac, using DC distribution within the server…”
MethodMedium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249 · cited 2×
“Traditionally, the devices with the most use are high-voltage insulated gate bipolar transistors (IGBTs) [6], [7], [9], [10], [13], based on a three-level neutral point clamped (NPC) topology the 1.”
BackgroundMultilevel intelligent universal transformer for medium voltage applications
Lai, J.-S., Maitra, A., Mansoor, A., & Goodman, F. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518705 · Cited by 185 · cited 2×
“Traditionally, the devices with the most use are high-voltage insulated gate bipolar transistors (IGBTs) [6], [7], [9], [10], [13], based on a three-level neutral point clamped (NPC) topology the 1.”
BackgroundDesign and Experimental Testing of a Resonant DC–DC Converter for Solid-State Transformers
Ortiz, G., Leibl, M. G., Huber, J. E., & Kolar, J. W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2637827 · Cited by 143 · cited 5×
“FREEDM Gen ETH Design CPES III [12] [14]–[16] Design”
BackgroundMethodInfluentialOrtiz, G., Leibl, M., Kolar, J. W., & Apeldoorn, O. (2013) · 2013 IEEE 10th International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2013.6527217 · Cited by 126 · cited 2×
“The most frequently used topology is the dual active bridge (DAB) converter [8], [9], [11], [15]; except ASEA brown”
MethodDesign and hardware implementation of Gen-1 silicon based solid state transformer
Wang, G., Baek, S., Elliott, J., Kadavelugu, A., Wang, F., She, X., Dutta, S., Liu, Y., Zhao, T., Yao, W., et al. (2011) · 2011 Twenty-Sixth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2011.5744766 · Cited by 99 · cited 5×
“Wang’s transformer is made up of a laminated amorphous (Metglas SA2605SA1) with 3 kHz working frequency and 7 kW rated power [9].”
BackgroundMethodInfluential
Research works printed but not linked: 5
- jaritz, 0, Isolation design of a 14.4�kV, 100�kHz transformer with a high isolation voltage (115�kV), Proc Power Modulator High Voltage Conf, 73
- 2005, Information Technology Equipment - Safety - Part 1 General Requirements
- 2015, General Requirements for Dry-Type Distribution and Power Transformers
- chanda, 2007, Plastic Technology Handbook
- 2014, National Electrical Code, 70
Cited by
Items 201–231 of 231
High Frequency Transformer Based Dual Active Bridge Converters for DFIG Wind Turbine Systems
Parveen, T., Tiery, J., & Lu, J. (2021) · Australasian Universities Power Engineering Conference · doi:10.1109/aupec52110.2021.9597752
“It has been documented that these high frequency transformers can also reach the same efficiency ratings as the low frequency transformers, with some reaching as much as 97% efficiency [8].”
BackgroundLiu, Y., Li, L., Li, M., Li, Y., Liu, H., Huang, M., Su, G., & Wang, F. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-19-1922-0_29
Zhang, X., Lin, F., Ma, H., Zhao, B., & Huang, J. (2023) · Springer eBooks · doi:10.1007/978-981-19-9115-8_3
Zhang, X., Lin, F., Ma, H., Zhao, B., & Huang, J. (2023) · Springer eBooks · doi:10.1007/978-981-19-9115-8_4
Zhang, X., Li, X., Ma, H., Jingjing, H., & Zeng, Z. (2023) · Springer eBooks · doi:10.1007/978-981-99-0459-4_6
2018 Index IEEE Transactions on Power Electronics Vol. 33
(2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3272449
Design Solutions for Reducing AC resistance of High Frequency Windings
Petrescu, L., Cazacu, E., Ioniţă, V., & Petrescu, M.-C. (2023) · International Conference on Modern Power Systems (MPS) · doi:10.1109/mps58874.2023.10187533
“Current technology leads to the increasing use of electromagnetic devices operating at very high frequencies (hundreds of kHz) [1-3].”
Background10 kVac/270 Vdc Medium-Voltage-Connecting Power Supply for Data Centers
Wu, X., Long, H., Jiang, Y., Deng, J., & Xu, D. (2023) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2023-ecceasia54778.2023.10213847
“In addition, it will add auxiliary functions such as interaction with the grid, flexibility to connect renewable energy and energy storage [1], [2].”
BackgroundMethodFast Chargers for Plug-In Electric and Hybrid Vehicles
Mi, C. C., Li, S., & Lu, S. (2024) · Green energy and technology · doi:10.1007/978-981-99-3060-9_9
Solid-state transformer and magnetic properties with potential topologies
Li, Y., Yang, M., & Bahman, A. S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-85622-5.00009-2
Liu, Z., Zhu, L., Dang, Y., & Ji, S. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567304
Novel Single-Stage High-Frequency-Isolated Four-Switch Bidirectional Single-Phase PFC Rectifier
Herzog, R., Menzi, D., Leibl, M., Huber, J., & Kolar, J. W. (2024) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel57542.2024.10614031
“The total losses of the inductors and the transformer, are highly dependent on the specific realization of the components and a trade-off exists between compactness and efficiency of these passives [19], [20].”
BackgroundTian, Y. F., Wang, Y., Wang, F., & Liu, B. (2024) · Lecture notes in electrical engineering · doi:10.1007/978-981-97-8824-8_12
A Novel Technical Approach for Battery Self-Heating in Electric Vehicles based on Inherent Resonance
Ji, F., Chen, Z., Li, Y., Wu, C., Wang, T., & Liu, Y. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861645
Teng, F., Galamb, A., & Lukic, S. M. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10860921
“Reference [10] introduces an MFT design for power converters to connect to 4160 V distribution system.”
Fang, S., Shu, S., Wang, G., Wang, K., Zeng, J., & Shi, G. (2025) · Asia Energy and Electrical Engineering Symposium (AEEES) · doi:10.1109/aeees64634.2025.11019076
Study on Multi-Bus Feeding Conversion System for Data Centers
Lin, Z., He, Y., Zhou, Y., & Hang, L. (2025) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg62294.2025.11060115
“Solid-State Transformers (SST) have become a research hotspot in academia and industry in recent years[9][10][11][12].”
A Hybrid Modulation Strategy for Parameter Deviation of Three-Port Isolated Resonant DC/DC Converter
Chen, S., Liu, J., Guo, T., Li, J., Chen, P., & Zhu, B. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3621764
Bolzonella, L., Mirzadarani, R., & Niasar, M. G. (2025) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon58223.2025.11221021 · Cited by 1
“Solid-State Transformers (SSTs) have emerged as a promising alternative to traditional 50Hz transformers in such applications, offering improved control-lability, modularity, and significantly higher power density due to operation at elevated switching frequencies [1].”
Lee, S., Kwon, M., Lee, J., & Cha, H. (2026) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2025.3633730
“Various high-frequency MV transformer designs employing di ff erent insulation materials have been proposed in recent studies [6], [7], [8], [9], [10], [11], [12], [13], [14], [15], [16], [17], [18].”
An Improved Integrated Transformer With Lower Eddy Loss for Combined OBC and LDC System
Zhou, C., Xu, J., Huang, R., Guo, X., & Cao, H. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3651405
“A widely used strategy is to separate the primary and the secondary windings of the OBC [14], [15], [16], [17].”
Huang, M., Liao, H.-X., Hu, J.-C., Chen, S., & Kuo, S.-C. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3668084
“Since the windings on both sides are partially exposed outside the magnetic structure, flux leakage may occur, potentially leading to EMI during circuit operation [36].”
Analysis of a Novel Three-Port Single-Stage Bidirectional DC–AC Converter for PV-ESS-V2G System
Liu, C. H., Bao, Y., Deng, C., Zhang, F., Wang, D., Chen, H., Ma, W., Jiang, F., & Chen, M. (2026) · Electronics · doi:10.3390/electronics15071360
FEA-Driven High-Frequency Transformer Design, Fabrication and Loss characterization
Dissanayake, T. L., Rallabandi, V., Wodja, R., Hickey, C., Kotre, E., Wijethunga, S., Gomez, P., & Kuruppu, S. S. (2026) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec51134.2026.11516688
“…skin and proximity effects for loss minimization in DAB converters [2]; design methodologies for offshore transformers with stringent isolation requirements [3]; and modular medium-voltage AC to low-voltage DC transformer designs that achieve high insulation, efficiency, and power density [1].”
A High-Frequency Planar Transformer with Medium-Voltage Isolation and Embedded Thermal Management
Sinha, S., Ahmed, Z., Diebold, J., & Maksimović, D. (2026) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec51134.2026.11517098
A review of power loss measurement method for high-frequency transformer
Zhu, L., Liu, Z., Dang, Y., Zhang, S., Zhang, G., & Ji, S. (2026) · Renewable Energy System and Equipment · doi:10.1016/j.rese.2026.05.002
Wang, J., Lu, J., Wei, W., Ding, T., Wang, C., Chen, K., & Zhang, J. (2026) · International Symposium on Autonomous Systems (ISAS) · doi:10.1109/icaisisas68969.2026.11567809
“The update formulas for the LSTM network are [16]: where i t , f t , and o t are the input gate, forget gate, and output gate, respectively, is element-wise multiplication, σ is the Sigmoid function, and tanh is the hyperbolic tangent function [17].”
Wijethunga, S., Dissanayake, T. L., Roy, S., Meyer, R. T., & Kuruppu, S. S. (2026) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/iteceats66641.2026.11593055
“High frequency transformers (HFT) are widely used in power electronic applications as DC-DC converters providing voltage scaling, high power density operations, and galvanic isolation [1].”
Control of the LLC Converter with Wide Load Range
Wu, X., Niu, M., Wang, H., Long, H., Wang, W., & Xu, D. (2026) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-nagasaki2026-ec64663.2026.11597433
“Compared with the conventional AC UPS architecture and HVDC architecture in data center power supply system, the architecture based on solid state transformers (SSTs) removes the bulky line-frequency transformers and reduces the consumption of copper materials [1].”
Loss model correction for high-frequency transformers with nanocrystalline cores
Dai, Z., Zhang, M., Song, W., Wang, L., Liu, C., Furao, Y., Wang, H., & Zhang, X. (2026) · Journal of Power Electronics · doi:10.1007/s43236-026-01379-0
Metadata
- Authors
- Zhao, S., Li, Q., Lee, F. C., & Li, B.
- Affiliations
- Virginia Tech (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-09
- Volume
- 33
- Issue
- 9
- Pages
- 7545-7557
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2770903482
- Cited by
- 231
- References
- 21
- Citations by year
- 2026: 12 · 2025: 17 · 2024: 30 · 2023: 31 · 2022: 37 · 2021: 46 · 2020: 23 · 2019: 22 · 2018: 11
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- Office of Energy Efficiency and Renewable Energy, U.S. Department of Energy (DE-EE0006521)
- Virginia Polytechnic Institute and State University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- high-frequency transformer design, CLLC resonant converter, DC-DC converter, modular power conversion, microgrids, transformer insulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.