CoChat

High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC

Open access
Zhao, Shishuo, Li, Qiang, Lee, Fred C., Li, Bin · 2018 · IEEE Transactions on Power Electronics

The DOI matches its Crossref record; 19 of the 21 references it cites were found in a registry or an index.

Abstract

This paper presents a high-frequency modular medium-voltage AC (4160 VAC or 13.8 kVAC) to low-voltage DC (400 VDC) system that is scalable in order to be used for different scale microgrids. A 15 kW, 500 kHz DC/DC converter is demonstrated as the most important stage of the system overall, which can be scalable to a 225 kW 4160 VAC to 400 VDC system. Motivation of a CLLC resonant converter and its design parameters determination is carefully illustrated. The high-frequency transformer is the key element for the DC/DC converter. Then, the paper focuses on high-frequency transformer design to realize high-voltage insulation, high efficiency, and high density at the same time. Based on a split winding UU core transformer structure, transformer insulation materials and dimension parameters are determined referring to the IEEE insulation standard. The transformer magnetic loss model is reviewed based on which loss design tradeoff is carefully analyzed. Different working frequency impact on transformer design over three different core materials is also presented. Finally, a 500 kHz transformer prototype has been developed and demonstrated with the IEEE standard required insulation tests. A whole CLLC resonant converter is also present with experiments results. The converter holds outstanding 98% efficiency and 2.9 kW/L power density.

Overview

Integrity signals

Registry

Crossref · 10.1109/tpel.2017.2774440

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Research works printed but not linked: 5

  1. jaritz, 0, Isolation design of a 14.4�kV, 100�kHz transformer with a high isolation voltage (115�kV), Proc Power Modulator High Voltage Conf, 73
  2. 2005, Information Technology Equipment - Safety - Part 1 General Requirements
  3. 2015, General Requirements for Dry-Type Distribution and Power Transformers
  4. chanda, 2007, Plastic Technology Handbook
  5. 2014, National Electrical Code, 70

Cited by

See all 231

Metadata

Authors
Zhao, S., Li, Q., Lee, F. C., & Li, B.
Affiliations
Virginia Tech (US)
Venue
IEEE Transactions on Power Electronics
Published
2018-09
Volume
33
Issue
9
Pages
7545-7557
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2770903482
Cited by
231
References
21
Citations by year
2026: 12 · 2025: 17 · 2024: 30 · 2023: 31 · 2022: 37 · 2021: 46 · 2020: 23 · 2019: 22 · 2018: 11
FWCI
6.60
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Power Electronics (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
Funders
  • Office of Energy Efficiency and Renewable Energy, U.S. Department of Energy (DE-EE0006521)
  • Virginia Polytechnic Institute and State University
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
Keywords
high-frequency transformer design, CLLC resonant converter, DC-DC converter, modular power conversion, microgrids, transformer insulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.