The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Sizing of an Energy Storage System for Grid Inertial Response and Primary Frequency Reserve
Open accessAbstract
Large-scale integration of renewable energy sources in power system leads to the replacement of conventional power plants (CPPs) and consequently challenges in power system reliability and security are introduced. This study is focused on improving the grid frequency response after a contingency event in the power system with a high penetration of wind power. An energy storage system (ESS) might be a viable solution for providing inertial response and primary frequency regulation. A methodology has been presented here for the sizing of the ESS in terms of required power and energy. It describes the contribution of the ESS to the grid, in terms of inertial constant and droop. The methodology is applied to a 12-bus grid model with high wind power penetration. The estimated ESS size for inertial response and primary frequency regulation services are validated through real-time simulations. Moreover, it is demonstrated that the ESS can provide the response similar to that provided by the CPPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719
Power system dynamics : stability and control
Machowski, J., Bialek, J. W., & Bumby, J. R. (2008) · Durham Research Online (Durham University) · Cited by 2,348
Delille, G., Francois, B., & Malarange, G. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2205025 · Cited by 776
Optimizing a Battery Energy Storage System for Primary Frequency Control
Oudalov, A., Chartouni, D., & Ohler, C. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901459 · Cited by 536
Inertia Emulation Control Strategy for VSC-HVDC Transmission Systems
Zhu, J., Booth, C. D., Adam, G. P., Roscoe, A. J., & Bright, C. G. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2213101 · Cited by 466
Masuta, T., & Yokoyama, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2194746 · Cited by 322
Primary Frequency Response From Electric Vehicles in the Great Britain Power System
Mu, Y., Wu, J., Ekanayake, J., Jenkins, N., & Jia, H. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2220867 · Cited by 290
A New Frequency Regulation Strategy for Photovoltaic Systems Without Energy Storage
Xin, H., Liu, Y., Wang, Z., Gan, D., & Yang, T. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2261567 · Cited by 277
Serban, I., & Marinescu, C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2283298 · Cited by 274
Cited by
Meng, L., Zafar, J., Khadem, S. K., Collinson, A., Murchie, K. C., Coffele, F., & Burt, G. M. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2940173 · Cited by 364
Stroe, D.-I., Knap, V., Swierczynski, M., Stroe, A.-I., & Teodorescu, R. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616319 · Cited by 351
Self-citationAkram, U., Nadarajah, M., Shah, R., & Milano, F. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109626 · Cited by 351
Grid-connected battery energy storage system: a review on application and integration
Zhao, C., Andersen, P. B., Træholt, C., & Hashemi, S. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113400 · Cited by 305
Primary Frequency Response in Capacity Expansion with Energy Storage
Carrion, M., Dvorkin, Y., & Pandzic, H. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2735807 · Cited by 70
Xavier, L. S., Amorim, W. C. S., Cupertino, A. F., Mendes, V. F., do Boaventura, W. C., & Pereira, H. A. (2019) · BMC Energy · doi:10.1186/s42500-019-0006-5 · Cited by 61
Metadata
- Authors
- Knap, V., Chaudhary, S. K., Stroe, D.-I., Swierczynski, M., Craciun, B.-I., & Teodorescu, R.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2016-09
- Volume
- 31
- Issue
- 5
- Pages
- 3447-3456
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2338338790
- Cited by
- 424
- References
- 23
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.