Smart Fault Location for Smart Grids
Abstract
Fault location is an important application among intelligent monitoring and outage management tasks used for realization of self healing networks, one of the most attractive features of smart grids. The data gathered from various intelligent electronic devices (IEDs) installed throughout the power system could be utilized for smart approaches to locating faults in both transmission and distribution systems. This paper discusses issues associated with improving accuracy of fault location methods in smart grids using an abundance of IED data. Two examples of how the gathered data from different IEDs is used to improve fault location accuracy in transmission and distribution systems are discussed in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Genetic algorithms in search, optimization, and machine learning
(1989) · Choice Reviews Online · doi:10.5860/choice.27-0936 · Cited by 49,010
Genetic Algorithms in Search, Optimization and Machine Learning
Goldberg, D. E., & Robson, D. (1988) · Cited by 18,391
Goldberg, D. E., & Shakespeare, W. (2002) · Cited by 16,088
Electric Power Distribution Reliability
Brown, R. E. (2002) · CRC Press eBooks · doi:10.1201/9780824744281 · Cited by 795
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635 · cited 1×
“The fact that fault causes voltage sags with different characteristics at different nodes has been utilized for fault location in [39] and [40].”
BackgroundImpact of Smart Grid on distribution system design
Brown, R. E. (2008) · 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century · doi:10.1109/pes.2008.4596843 · Cited by 475
A Lightweight Message Authentication Scheme for Smart Grid Communications
Fouda, M. M., Fadlullah, Z. M., Kato, N., Lu, R., & Shen, X. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2160661 · Cited by 457
A new fault location technique for two- and three-terminal lines
Girgis, A. A., Hart, D. G., & Peterson, W. L. (1992) · IEEE Transactions on Power Delivery · doi:10.1109/61.108895 · Cited by 374
Comparison of impedance based fault location methods for power distribution systems
Mora-Flòrez, J., Meléndez, J., & Carrillo-Caicedo, G. (2008) · Electric Power Systems Research · doi:10.1016/j.epsr.2007.05.010 · Cited by 286
Unsynchronized two-terminal fault location estimation
Novosel, D., Hart, D. G., Udren, E., & Garitty, J. (1996) · IEEE Transactions on Power Delivery · doi:10.1109/61.484009 · Cited by 270
Cited by
Chen, K., Huang, C., & He, J. (2016) · High Voltage · doi:10.1049/hve.2016.0005 · Cited by 377
A survey on the critical issues in smart grid technologies
Colak, I., Sagiroglu, S., Fulli, G., Yesilbudak, M., & Covrig, C.-F. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.036 · Cited by 297
Chen, C., Wang, J., & Ton, D. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2684780 · Cited by 293
Zidan, A., Khairalla, M., Abdrabou, A. M., Khalifa, T., Shaban, K., Abdrabou, A., El Shatshat, R., & Gaouda, A. M. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2517620 · Cited by 274
A Machine Learning and Wavelet-Based Fault Location Method for Hybrid Transmission Lines
Livani, H., & Evrenosoglu, C. Y. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2260421 · Cited by 265
Chen, K., Hu, J., & He, J. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2598881 · Cited by 176
Jiang, H., Dai, X., Gao, D. W., Zhang, J. J., Zhang, Y., & Muljadi, E. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2552229 · Cited by 56
Metadata
- Authors
- Kezunovic, M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2011-03
- Volume
- 2
- Issue
- 1
- Pages
- 11-22
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2105049517
- Cited by
- 380
- References
- 30
- FWCI
- 42.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.