The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Smart Fault Location for Smart Grids
Abstract
Fault location is an important application among intelligent monitoring and outage management tasks used for realization of self healing networks, one of the most attractive features of smart grids. The data gathered from various intelligent electronic devices (IEDs) installed throughout the power system could be utilized for smart approaches to locating faults in both transmission and distribution systems. This paper discusses issues associated with improving accuracy of fault location methods in smart grids using an abundance of IED data. Two examples of how the gathered data from different IEDs is used to improve fault location accuracy in transmission and distribution systems are discussed in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Genetic algorithms in search, optimization, and machine learning
(1989) · Choice Reviews Online · doi:10.5860/choice.27-0936 · Cited by 49,010
Genetic Algorithms in Search, Optimization and Machine Learning
Goldberg, D. E., & Robson, D. (1988) · Cited by 18,391
Goldberg, D. E., & Shakespeare, W. (2002) · Cited by 16,088
Electric Power Distribution Reliability
Brown, R. E. (2002) · CRC Press eBooks · doi:10.1201/9780824744281 · Cited by 795
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635 · cited 1×
“The fact that fault causes voltage sags with different characteristics at different nodes has been utilized for fault location in [39] and [40].”
BackgroundImpact of Smart Grid on distribution system design
Brown, R. E. (2008) · 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century · doi:10.1109/pes.2008.4596843 · Cited by 475
A Lightweight Message Authentication Scheme for Smart Grid Communications
Fouda, M. M., Fadlullah, Z. M., Kato, N., Lu, R., & Shen, X. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2160661 · Cited by 457
A new fault location technique for two- and three-terminal lines
Girgis, A. A., Hart, D. G., & Peterson, W. L. (1992) · IEEE Transactions on Power Delivery · doi:10.1109/61.108895 · Cited by 374
Comparison of impedance based fault location methods for power distribution systems
Mora-Flòrez, J., Meléndez, J., & Carrillo-Caicedo, G. (2008) · Electric Power Systems Research · doi:10.1016/j.epsr.2007.05.010 · Cited by 286
Unsynchronized two-terminal fault location estimation
Novosel, D., Hart, D. G., Udren, E., & Garitty, J. (1996) · IEEE Transactions on Power Delivery · doi:10.1109/61.484009 · Cited by 270
Sachdev, M. S., & Agarwal, R. (1988) · IEEE Transactions on Power Delivery · doi:10.1109/61.4237 · Cited by 235
Accurate fault location technique for power transmission lines
Johns, A. T., & Jamali, S. (1990) · IEE Proceedings C Generation, Transmission and Distribution · doi:10.1049/ip-c.1990.0054 · Cited by 232
Eriksson, L., Saha, M., & Rockefeller, G. (1985) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1985.319058 · Cited by 229
A fault location technique for rural distribution feeders
Girgis, A. A., Fallon, C. M., & Lubkeman, D. L. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.259729 · Cited by 194
A fault location technique for rural distribution feeders
Girgis, A. A., Fallon, C. M., & Lubkeman, D. L. (2002) · [Proceedings] 1991 Rural Electric Power Conference. Papers presented at the 35th Annual Conference · doi:10.1109/repcon.1991.153081 · Cited by 188
Fault Location on a Transmission Line Using Synchronized Voltage Measurements
Brahma, S. M., & Girgis, A. A. (2004) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.822532 · Cited by 175
Mora-Florez, J., Barrera-Nunez, V., & Carrillo-Caicedo, G. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.883021 · Cited by 166
Improved Fault Location on Distribution Feeders Based on Matching During-Fault Voltage Sags
Pereira, R. A. F., da Silva, L. G. W., Kezunovic, M., & Mantovani, J. R. S. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2014480 · Cited by 159
Self-citationTakagi, T., Yamakoshi, Y., Baba, J., et al. (1981) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1981.316604 · Cited by 139
New multi-ended fault location design for two- or three-terminal lines
(2001) · doi:10.1049/cp:20010183 · Cited by 122
A New Fault Location Algorithm for Radial Transmission Lines with Loads
Srinivasan, K., & St-Jacques, A. (1989) · IEEE Power Engineering Review · doi:10.1109/mper.1989.4310803 · Cited by 112
A Direct Three-Phase Circuit Analysis-Based Fault Location for Line-to-Line Fault
Choi, M.-S., Lee, S., Lim, S.-I., Lee, D.-S., & Yang, X. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.905535 · Cited by 109
Fault location using voltage measurements
Galijasevic, Z., & Abur, A. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997915 · Cited by 105
An accurate fault location algorithm using synchronized sampling
Kezunović, M., Mrkic, J., & Perunicic-Drazenovic, B. (1994) · Electric Power Systems Research · doi:10.1016/0378-7796(94)90011-6 · Cited by 104
Fault Location Using Voltage Measurements
Galijasevic, Z., & Abur, A. (2001) · IEEE Power Engineering Review · doi:10.1109/mper.2001.4311159 · Cited by 84
Fault Location in Power Distribution Systems using ANFIS Nets and Current Patterns
Mora, J., Carrillo, G., & Pérez, L. P. (2006) · IEEE PES Transmission & Distribution Conference and Exposition - Latin America (PES T&D-LA) · doi:10.1109/tdcla.2006.311428 · Cited by 61
Schweitzer, E. O. (1983) · Computers & Electrical Engineering · doi:10.1016/0045-7906(83)90013-7 · Cited by 52
Using PQ Monitoring and Substation Relays for Fault Location on Distribution Systems
Short, T. A., Sabin, D. D., & McGranaghan, M. F. (2007) · IEEE Rural Electric Power Conference (REPC) · doi:10.1109/repcon.2007.369552 · Cited by 27
Kezunović, M., Akleman, E., Knezev, M., et al. (2007) · doi:10.1109/irep.2007.4410534 · Cited by 16
Knezev, M. (2009) · OakTrust (Texas A&M University Libraries) · Cited by 3
Cited by
Chen, K., Huang, C., & He, J. (2016) · High Voltage · doi:10.1049/hve.2016.0005 · Cited by 377
A survey on the critical issues in smart grid technologies
Colak, I., Sagiroglu, S., Fulli, G., Yesilbudak, M., & Covrig, C.-F. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.036 · Cited by 297
Chen, C., Wang, J., & Ton, D. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2684780 · Cited by 293
Zidan, A., Khairalla, M., Abdrabou, A. M., Khalifa, T., Shaban, K., Abdrabou, A., El Shatshat, R., & Gaouda, A. M. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2517620 · Cited by 274
A Machine Learning and Wavelet-Based Fault Location Method for Hybrid Transmission Lines
Livani, H., & Evrenosoglu, C. Y. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2260421 · Cited by 265
Metadata
- Authors
- Kezunovic, M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2011-03
- Volume
- 2
- Issue
- 1
- Pages
- 11-22
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2105049517
- Cited by
- 380
- References
- 30
- FWCI
- 42.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.