Blind False Data Injection Attack Using PCA Approximation Method in Smart Grid
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Accurate state estimation is of paramount importance to maintain normal operations of smart power grids. However, recent research shows that carefully produced attacks with the knowledge of the grid topology, i.e., Jacobian matrix, can bypass the bad data detection (BDD) system. The BDD is used to ensure the integrity of state estimation to filter faulty measurements introduced by device malfunctions or malicious attacks. However, to construct the false data injection attack vectors, a common assumption in most prior works on false data injection attacks is that the attacker has complete knowledge about the power grid topology and transmission-line admittances. By contrast, this paper studies the general problem of blind false data injection attacks using the principal component analysis approximation method without the knowledge of Jacobian matrix and the assumption regarding the distribution of state variables. The proposed attack is proven to be approximately stealthy.1The performance of the proposed attack is analyzed. Simulations confirm the performance of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Generation, Operation, and Control
Wood, A. J., & Wollenberg, B. F. (1984) · Cited by 8,303
Zimmerman, R. D., Murillo-Sanchez, C. E., & Thomas, R. J. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2051168 · Cited by 6,756
Ipakchi, A., & Albuyeh, F. (2009) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.931384 · Cited by 1,644 · cited 1×
“Recent advances in smart grid can significantly enhance efficiency and reliability of power grids [1].”
BackgroundToward a smart grid: power delivery for the 21st century
Massoud Amin, S., & Wollenberg, B. F. (2005) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2005.1507024 · Cited by 1,630
Stott, B., & Alsac, O. (1974) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1974.293985 · Cited by 1,522
A Survey on Smart Grid Communication Infrastructures: Motivations, Requirements and Challenges
Yan, Y., Qian, Y., Sharif, H., & Tipper, D. (2013) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2012.021312.00034 · Cited by 1,315
False data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2009) · Proceedings of the 16th ACM conference on Computer and communications security · doi:10.1145/1653662.1653666 · Cited by 1,285
Malicious Data Attacks on the Smart Grid
Kosut, O., Jia, L., Thomas, R. J., & Tong, L. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2163807 · Cited by 784
Electric power system state estimation
Monticelli, A. (2000) · Proceedings of the IEEE · doi:10.1109/5.824004 · Cited by 767
A Survey on Cyber Security for Smart Grid Communications
Yan, Y., Qian, Y., Sharif, H., & Tipper, D. (2012) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2012.010912.00035 · Cited by 716
Cited by
A Survey on State Estimation Techniques and Challenges in Smart Distribution Systems
Dehghanpour, K., Wang, Z., Wang, J., Yuan, Y., & Bu, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2870600 · Cited by 485
Cyber‐physical attacks and defences in the smart grid: a survey
He, H., & Yan, J. (2016) · IET Cyber-Physical Systems: Theory & Applications · doi:10.1049/iet-cps.2016.0019 · Cited by 454
Online False Data Injection Attack Detection With Wavelet Transform and Deep Neural Networks
Yu, J. J. Q., Hou, Y., & Li, V. O. K. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2825243 · Cited by 378
Artificial Intelligence Techniques in Smart Grid: A Survey
Omitaomu, O. A., & Niu, H. (2021) · Smart Cities · doi:10.3390/smartcities4020029 · Cited by 371
Evaluation of Reinforcement Learning-Based False Data Injection Attack to Automatic Voltage Control
Chen, Y., Huang, S., Liu, F., Wang, Z., & Sun, X. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2790704 · Cited by 227
“Blind FDI attacks were proposed in [14].”
MethodResilient Control Design for Load Frequency Control System Under False Data Injection Attacks
Abbaspour, A., Sargolzaei, A., Forouzannezhad, P., Yen, K. K., & Sarwat, A. I. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2944091 · Cited by 219
“In [28], PCA was used to ensure the integrity of data in state estimation of the power grid by filtering of faulty measurements.”
MethodState of the art of cyber-physical systems security: An automatic control perspective
Zacchia Lun, Y., D’Innocenzo, A., Smarra, F., Malavolta, I., & Di Benedetto, M. D. (2019) · Journal of Systems and Software · doi:10.1016/j.jss.2018.12.006 · Cited by 211
Reda, H. T., Anwar, A., & Mahmood, A. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112423 · Cited by 197
“And, only few researches [47] [48] have studied the FDI attack under both the DC and AC power flow models.”
BackgroundA Review of Cyber–Physical Security for Photovoltaic Systems
Ye, J., Giani, A., Elasser, A., Mazumder, S. K., Farnell, C., Mantooth, H. A., Kim, T., Liu, J., Chen, B., Seo, G.-S., et al. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3111728 · Cited by 164
Survey of machine learning methods for detecting false data injection attacks in power systems
Sayghe, A., Hu, Y., Zografopoulos, I., Liu, X., Dutta, R. G., Jin, Y., & Konstantinou, C. (2020) · IET Smart Grid · doi:10.1049/iet-stg.2020.0015 · Cited by 159
Detection and Differentiation of Replay Attack and Equipment Faults in SCADA Systems
Li, D., Gebraeel, N., & Paynabar, K. (2021) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2020.3013760 · Cited by 68
Metadata
- Authors
- Yu, Z.-H., & Chin, W.-L.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015-05
- Volume
- 6
- Issue
- 3
- Pages
- 1219-1226
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2075565671
- Cited by
- 305
- References
- 26
- FWCI
- 23.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.