Droop-Based Distributed Cooperative Control for Microgrids With Time-Varying Delays
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
This paper develops a droop-based distributed cooperative control scheme for microgrids under a switching communication network with non-uniform time-varying delays. We first design a pinning-based frequency/voltage controller containing a distributed voltage observer and then design a consensus-based active/reactive power controller, which are employed into the secondary control stage to generate the nominal set points used in the primary control stage for different distributed generators (DGs). By this approach, the frequencies and the weighted average value of all DGs’ voltages can be pinned to the desired values while maintaining the precise active and reactive power sharing. With the proposed scheme, each DG only needs to communicate with its neighbors intermittently, even if their communication networks are local and time-varying, and their variant delays may be non-uniform. Sufficient conditions on the requirements for the network connectivity and the delay upper bound that guarantee the stability and reliability of the microgrid are presented. The effectiveness of the proposed control scheme is verified by the simulation of a microgrid test system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 1×
“Roughly speaking, the basic control strategy for microgrids is the hierarchical control [4], including primary control (droop control) [5], [6], secondary control (restoration of voltage and”
BackgroundModeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Distributed Secondary Control for Islanded Microgrids—A Novel Approach
Shafiee, Q., Guerrero, J. M., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2259506 · Cited by 1,069
On pinning synchronization of complex dynamical networks
Yu, W., Chen, G., & Lü, J. (2009) · Automatica · doi:10.1016/j.automatica.2008.07.016 · Cited by 1,016
Secondary Frequency and Voltage Control of Islanded Microgrids via Distributed Averaging
Simpson-Porco, J. W., Shafiee, Q., Dorfler, F., Vasquez, J. C., Guerrero, J. M., & Bullo, F. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2436879 · Cited by 974
Zhang, H., Lewis, F. L., & Das, A. (2011) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2011.2139510 · Cited by 946
Distributed Cooperative Secondary Control of Microgrids Using Feedback Linearization
Bidram, A., Davoudi, A., Lewis, F. L., & Guerrero, J. M. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2247071 · Cited by 924
Robust Droop Controller for Accurate Proportional Load Sharing Among Inverters Operated in Parallel
Zhong, Q.-C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2146221 · Cited by 890
Cited by
Antoniadou-Plytaria, K. E., Kouveliotis-Lysikatos, I. N., Georgilakis, P. S., & Hatziargyriou, N. D. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2679238 · Cited by 545
“…the solution of the problem, including the small voltage angle difference between buses [20], lossless power lines [20], constant R/X ratio along the feeders (e.g., [10] and [12]) or the electric proximity between DG units (e.g., [21] and [22]), which is a typical assumption adopted for microgrids.”
BackgroundMethodDC Microgrid Planning, Operation, and Control: A Comprehensive Review
Al-Ismail, F. S. (2021) · IEEE Access · doi:10.1109/access.2021.3062840 · Cited by 542
Distributed Control Strategies for Microgrids: An Overview
Espina, E., Llanos, J., Burgos-Mellado, C., Cardenas-Dobson, R., Martinez-Gomez, M., & Saez, D. (2020) · IEEE Access · doi:10.1109/access.2020.3032378 · Cited by 415
On the Secondary Control Architectures of AC Microgrids: An Overview
Khayat, Y., Shafiee, Q., Heydari, R., Naderi, M., Dragicevic, T., Simpson-Porco, J. W., Dorfler, F., Fathi, M., Blaabjerg, F., Guerrero, J. M., et al. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2951694 · Cited by 385
Ding, L., Han, Q.-L., & Zhang, X.-M. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2884494 · Cited by 358
Lu, X., Yu, X., Lai, J., Guerrero, J. M., & Zhou, H. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2603844 · Cited by 286
Self-citationMicrogrid control: A comprehensive survey
Sen, S., & Kumar, V. (2018) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2018.04.012 · Cited by 228
Metadata
- Authors
- Lai, J., Zhou, H., Lu, X., Yu, X., & Hu, W.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2016-07
- Volume
- 7
- Issue
- 4
- Pages
- 1775-1789
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2336141656
- Cited by
- 334
- References
- 29
- FWCI
- 40.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.