Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
1. Hypertension and atrial fibrillation (AF) often coexist and are strong risk factors for stroke. Current guidelines for blood pressure (BP) measurement in AF recommend repeated measurements using the auscultatory method, whereas the accuracy of the automated devices is regarded as questionable. This review presents the current evidence on the feasibility and accuracy of automated BP measurement in the presence of AF and the potential for automated detection of undiagnosed AF during such measurements. 2. Studies evaluating the use of automated BP monitors in AF are limited and have significant heterogeneity in methodology and protocols. Overall, the oscillometric method is feasible for static (office or home) and ambulatory use and appears to be more accurate for systolic than diastolic BP measurement. 3. Given that systolic hypertension is particularly common and important in the elderly, the automated BP measurement method may be acceptable for self-home and ambulatory monitoring, but not for professional office or clinic measurement. 4. An embedded algorithm for the detection of asymptomatic AF during routine automated BP measurement with high diagnostic accuracy has been developed and appears to be a useful screening tool for elderly hypertensives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Benjamin, E. J. (1994) · JAMA · doi:10.1001/jama.1994.03510350050036 · Cited by 2,613 · cited 1×
“Hypertension per se is a major risk factor for AF, and both hypertension and AF are independent risk factors for morbidity and mortality and are closely related to the risk of stroke.(5,6) Thus, hypertension with AF constitutes a common and particularly high-risk clinical situation in routine practice.”
BackgroundKannel, W. B., Wolf, P. A., Benjamin, E. J., & Levy, D. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00583-9 · Cited by 2,033 · cited 2×
“The prevalence of both hypertension and AF is predicted to increase in the coming decades.(3,4) Hypertension per se is a major risk factor for AF, and both hypertension and AF are independent risk factors for morbidity and mortality and are closely related to the risk of stroke.”
BackgroundO'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationMancia, G., Laurent, S., Agabiti-Rosei, E., Ambrosioni, E., Burnier, M., Caulfield, M. J., Cifkova, R., Clément, D., Coca, A., Dominiczak, A., et al. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e328333146d · Cited by 1,643
Danaei, G., Finucane, M. M., Lin, J. K., Singh, G. M., Paciorek, C. J., Cowan, M. J., Farzadfar, F., Stevens, G. A., Lim, S. S., Riley, L. M., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(10)62036-3 · Cited by 1,239
Manolis, A. J., Rosei, E. A., Coca, A., Cifkova, R., Erdine, S. E., Kjeldsen, S., Lip, G. Y. H., Narkiewicz, K., Parati, G., Redon, J., et al. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834f03bf · Cited by 198 · cited 2×
“of patients with hypertension and AF has been recently published by the European Society of Hypertension (ESH).(7)”
BackgroundAutomated blood pressure measurement in atrial fibrillation: a systematic review and meta-analysis
Stergiou, G. S., Kollias, A., Destounis, A., & Tzamouranis, D. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835850d7 · Cited by 120
Self-citationAtrial fibrillation—the growing epidemic
Lip, G. Y. H., Kakar, P., & Watson, T. (2007) · Heart · doi:10.1136/hrt.2006.110791 · Cited by 90 · cited 2×
“The prevalence of both hypertension and AF is predicted to increase in the coming decades.(3,4) Hypertension per se is a major risk factor for AF, and both hypertension and AF are independent risk factors for morbidity and mortality and are closely related to the risk of stroke.”
Background
Cited by
Blood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research
Muntner, P., Einhorn, P. T., Cushman, W. C., Whelton, P. K., Bello, N. A., Drawz, P. E., Green, B. B., Jones, D. W., Juraschek, S. P., Margolis, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.069 · Cited by 199
“This overestimation of DBP may be less important because most people with AF are older, a population wherein SBP has more prognostic importance (100).”
BackgroundSelf-citationStergiou, G. S., Kyriakoulis, K. G., Stambolliu, E., Destounis, A., Karpettas, N., Kalogeropoulos, P., & Kollias, A. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002201 · Cited by 67
“An AF-specific algorithm has been developed for detecting AF during routine automated BP measurement (Microlife Afib; Microlife AG, Widnau, Switzerland) [7,64,65].”
BackgroundMethodSelf-citationBlood pressure measurement in special populations and circumstances
Stergiou, G. S., Dolan, E., Kollias, A., Poulter, N. R., Shennan, A., Staessen, J. A., Zhang, Z., & Weber, M. A. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13296 · Cited by 29
Self-citationXie, F., Xu, J., Xia, L.-L., Luo, X., Jiang, Z., Wu, Y., & Su, H. (2020) · Hypertension Research · doi:10.1038/s41440-019-0386-4 · Cited by 21
Park, S.-H., & Choi, Y.-K. (2020) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000414 · Cited by 14
Metadata
- Authors
- Kollias, A., & Stergiou, G. S.
- Venue
- Clinical and Experimental Pharmacology and Physiology
- Publisher
- Wiley
- Published
- 2013-12-30
- Volume
- 41
- Issue
- 1
- Pages
- 9-15
- ISSN
- 0305-1870 (ISSN-L)
- OpenAlex
- W2092404197
- Cited by
- 29
- References
- 8
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.