Spectroscopic Characteristics of Human Melanin In Vivo
Open accessThe DOI matches its Crossref record.
Abstract
In this paper we present the absorption characteristics of human melanin in the visible range of wavelengths and specifically in the range 620-720 nm. The spectroscopy of melanin is studied by measuring remittance spectra of normal skin and vitiligo-involved skin of volunteers-patients. It is assumed that the spectral differences between adjacent areas of normally pigmented skin, and to some degree amelanotic skin, can only be due to the variations of the melanin filter. The ratio of the remittance spectrum of the vitiligo-involved skin with the spectrum of the normal skin in the range 620-720 nm can be fitted with a straight line for all the volunteers. A very strong correlation is obtained between the intercept and the slope for all the volunteers, which leads us to conclude that it is indeed melanin that we are measuring in all the volunteers and that it is the same substance spectroscopically for all the volunteers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Back to the Future: Achieving Health Equity Through Health Informatics and Digital Health
Brewer, L. C., Fortuna, K. L., Jones, C., Walker, R., Hayes, S. N., Patten, C. A., & Cooper, L. A. (2020) · JMIR mHealth and uHealth · doi:10.2196/14512 · Cited by 367
“Although there has been scant media attention surrounding this issue, it is well documented in the scientific literature that the inherent optical sensors or green lights of these devices are readily absorbed by melanin (skin pigment), presenting a problematic challenge to accurate monitoring of heart rate [7-10].”
BackgroundSkin Color Measurements in Terms of CIELAB Color Space Values
Weatherall, I. L., & Coombs, B. D. (1992) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12616156 · Cited by 365
From Extraction to Advanced Analytical Methods: The Challenges of Melanin Analysis
Pralea, I.-E., Moldovan, R.-C., Petrache, A.-M., Ilieș, M., Hegheș, S.-C., Ielciu, I., Nicoară, R., Moldovan, M., Ene, M., Radu, M., et al. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20163943 · Cited by 282
Raman spectroscopy of in vivo cutaneous melanin
Huang, Z., Lui, H., Chen, X. K., Alajlan, A., McLean, D. I., & Zeng, H. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1805553 · Cited by 248
Zonios, G., Dimou, A., Bassukas, I., Galaris, D., Tsolakidis, A., & Kaxiras, E. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2844710 · Cited by 246
“9,10 The results from these studies provide important qualitative information regarding the melanin absorption properties in its native envi-1083-3668 ronment, but the empirical nature of data analysis calls for a more extensive study.”
BackgroundBoulton, M., Docchio, F., Dayhaw-Barker, P., Ramponi, R., & Cubeddu, R. (1990) · Vision Research · doi:10.1016/0042-6989(90)90003-4 · Cited by 235
EEMCO guidance for the assessment of skin colour
Piérard, G. (1998) · Journal of the European Academy of Dermatology and Venereology · doi:10.1016/s0926-9959(97)00183-9 · Cited by 228
Non‐Invasive Measurements of Skin Pigmentation In Situ
Stamatas, G. N., Zmudzka, B. Z., Kollias, N., & Beer, J. Z. (2004) · Pigment Cell Research · doi:10.1111/j.1600-0749.2004.00204.x · Cited by 222
Self-citationChromophore concentrations, absorption and scattering properties of human skin in-vivo
Tseng, S.-H., Bargo, P., Durkin, A., & Kollias, N. (2009) · Optics Express · doi:10.1364/oe.17.014599 · Cited by 217
Self-citationHuman pigmentation variation: evolution, genetic basis, and implications for public health
Parra, E. J. (2007) · American Journal of Physical Anthropology · doi:10.1002/ajpa.20727 · Cited by 191
“Kollias and Baqer (1985, 1987) have shown that the amount of melanin in the skin can be estimated by DRS from the slope of the absorbance spectrum in the region between 620 and 720 nm.”
BackgroundShriver, M. D., & Parra, E. J. (2000) · American Journal of Physical Anthropology · doi:10.1002/(sici)1096-8644(200005)112:1<17::aid-ajpa3>3.0.co;2-d · Cited by 186
“Melanin, both in vivo and in vitro, shows absorbance of light of all wavelengths, essentially a flat line sloping down from the lower wavelengths to the higher wavelengths (Kollias and Baqer, 1985).”
BackgroundGambichler, T., Regeniter, P., Bechara, F. G., Orlikov, A., Vasa, R., Moussa, G., Stücker, M., Altmeyer, P., & Hoffmann, K. (2007) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2007.05.029 · Cited by 175
Césarini, J. P., Michel, L., Maurette, J. M., Adhoute, H., & Béjot, M. (2003) · Photodermatology, Photoimmunology & Photomedicine · doi:10.1034/j.1600-0781.2003.00044.x · Cited by 143
Kollias, N., Malallah, Y. H., Al‐Ajmi, H., Baqer, A., Johnson, B. E., & González, S. (1996) · Photodermatology, Photoimmunology & Photomedicine · doi:10.1111/j.1600-0781.1996.tb00197.x · Cited by 64
Self-citationKostrna, J., Oparina, E., Palacios, C., Rodriguez, A. J., Pei, J., Ajmal, A., & Ramella-Roman, J. C. (2026) · Sensors · doi:10.3390/s26102922 · Cited by 5
Metadata
- Authors
- Kollias, N., & Baqer, A.
- Venue
- Journal of Investigative Dermatology
- Publisher
- Elsevier BV
- Published
- 1985-07
- Volume
- 85
- Issue
- 1
- Pages
- 38-42
- ISSN
- 0022-202X (ISSN-L)
- OpenAlex
- W2033127683
- Cited by
- 134
- References
- 0
- FWCI
- 0.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.