The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
RT‐LAMP for rapid diagnosis of coronavirus SARS‐CoV‐2
Open accessAbstract
Summary: The pandemic coronavirus SARS‐CoV‐2 in the world has caused a large infected population suffering from COVID‐19. To curb the spreading of the virus, WHO urgently demanded an extension of screening and testing; thus, a rapid and simple diagnostic method is needed. We applied a reverse transcription‐loop‐mediated isothermal amplification (RT‐LAMP) to achieve the detection of SARS‐CoV‐2 in 30 min. We designed four sets of LAMP primers (6 primers in each set), targeting the viral RNA of SARS‐CoV‐2 in the regions of orf1ab, S gene and N gene. A colorimetric change was used to report the results, which enables the outcome of viral RNA amplification to be read by the naked eye without the need of expensive or dedicated instrument. The sensitivity can be 80 copies of viral RNA per ml in a sample. We validated the RT‐LAMP method in a hospital in China, employing 16 clinic samples with 8 positives and 8 negatives. The testing results are consistent with the conventional RT‐qPCR. In addition, we also show that one‐step process without RNA extraction is feasible to achieve RNA amplification directly from a sample. This rapid, simple and sensitive RT‐LAMP method paves a way for a large screening at public domain and hospitals, particularly regional hospitals and medical centres in rural areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Structure, function and antigenicity of the SARS-CoV-2 spike glycoprotein
Walls, A. C., Park, Y.-J., Tortorici, M. A., Wall, A., McGuire, A. T., & Veesler, D. (2020) · doi:10.1101/2020.02.19.956581 · Cited by 8,586
A novel coronavirus outbreak of global health concern
Wang, C., Horby, P. W., Hayden, F. G., & Gao, G. F. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30185-9 · Cited by 7,700
Origin and evolution of pathogenic coronaviruses
Cui, J., Li, F., & Shi, Z.-L. (2019) · Nature Reviews Microbiology · doi:10.1038/s41579-018-0118-9 · Cited by 5,515
Accelerated reaction by loop-mediated isothermal amplification using loop primers
Nagamine, K., Hase, T., & Notomi, T. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0415 · Cited by 2,045
Tomita, N., Mori, Y., Kanda, H., & Notomi, T. (2008) · Nature Protocols · doi:10.1038/nprot.2008.57 · Cited by 1,867
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Law, J. W.-F., Ab Mutalib, N.-S., Chan, K.-G., & Lee, L.-H. (2015) · Frontiers in Microbiology · doi:10.3389/fmicb.2014.00770 · Cited by 1,205
Mori, Y., & Notomi, T. (2009) · Journal of Infection and Chemotherapy · doi:10.1007/s10156-009-0669-9 · Cited by 1,015
Coronavirus Genomics and Bioinformatics Analysis
Woo, P. C. Y., Huang, Y., Lau, S. K. P., & Yuen, K.-Y. (2010) · Viruses · doi:10.3390/v2081803 · Cited by 913
A SARS-like cluster of circulating bat coronaviruses shows potential for human emergence
Menachery, V. D., Yount, B. L., Debbink, K., Agnihothram, S., Gralinski, L. E., Plante, J. A., Graham, R. L., Scobey, T., Ge, X.-Y., Donaldson, E. F., et al. (2015) · Nature Medicine · doi:10.1038/nm.3985 · Cited by 901
Drosten, C., Göttig, S., Schilling, S., Asper, M., Panning, M., Schmitz, H., & Günther, S. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.7.2323-2330.2002 · Cited by 631
Thai, H. T. C., Le, M. Q., Vuong, C. D., Parida, M., Minekawa, H., Notomi, T., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.5.1956-1961.2004 · Cited by 422
Reboud, J., Xu, G., Garrett, A., Adriko, M., Yang, Z., Tukahebwa, E. M., Rowell, C., & Cooper, J. M. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1812296116 · Cited by 351
Boehme, C. C., Nabeta, P., Henostroza, G., Raqib, R., Rahim, Z., Gerhardt, M., Sanga, E., Hoelscher, M., Notomi, T., Hase, T., et al. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02352-06 · Cited by 341
Detection of Human Influenza A Viruses by Loop-Mediated Isothermal Amplification
Poon, L. L. M., Leung, C. S. W., Chan, K. H., Lee, J. H. C., Yuen, K. Y., Guan, Y., & Peiris, J. S. M. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.1.427-430.2005 · Cited by 159
Poole, C. B., Li, Z., Alhassan, A., Guelig, D., Diesburg, S., Tanner, N. A., Zhang, Y., Evans, T. C., LaBarre, P., Wanji, S., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0169011 · Cited by 117
A novel method to control carryover contamination in isothermal nucleic acid amplification
Ma, C., Wang, F., Wang, X., Han, L., Jing, H., Zhang, H., & Shi, C. (2017) · Chemical Communications · doi:10.1039/c7cc06469a · Cited by 46
A Proposed New Rule at the US EPA Is Transparency Taken Too Far
(2019) · Cell · doi:10.1016/j.cell.2019.12.001 · Cited by 26
Cited by
Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Deeks, J. J., Adriano, A., Berhane, S., Davenport, C., Dittrich, S., Emperador, D., Takwoingi, Y., Cunningham, J., Beese, S., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705 · Cited by 1,156
Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Deeks, J. J., Berhane, S., Taylor, M., Adriano, A., Davenport, C., Dittrich, S., Emperador, D., Takwoingi, Y., Cunningham, J., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705.pub2 · Cited by 591
Loop-Mediated Isothermal Amplification (LAMP): The Better Sibling of PCR?
Soroka, M., Wasowicz, B., & Rymaszewska, A. (2021) · Cells · doi:10.3390/cells10081931 · Cited by 473
Rapid electrochemical detection of coronavirus SARS-CoV-2
Chaibun, T., Puenpa, J., Ngamdee, T., Boonapatcharoen, N., Athamanolap, P., O’Mullane, A. P., Vongpunsawad, S., Poovorawan, Y., Lee, S. Y., & Lertanantawong, B. (2021) · Nature Communications · doi:10.1038/s41467-021-21121-7 · Cited by 405
Detection of COVID-19: A review of the current literature and future perspectives
Ji, T., Liu, Z., Wang, G., Guo, X., Akbar khan, S., Lai, C., Chen, H., Huang, S., Xia, S., Chen, B., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112455 · Cited by 383
Self-citation
Metadata
- Authors
- Huang, W. E., Lim, B., Hsu, C., Xiong, D., Wu, W., Yu, Y., Jia, H., Wang, Y., Zeng, Y., Ji, M., Chang, H., Zhang, X., Wang, H., & Cui, Z.
- Venue
- Microbial Biotechnology
- Publisher
- Wiley
- Published
- 2020-04-25
- Volume
- 13
- Issue
- 4
- Pages
- 950-961
- ISSN
- 1751-7915 (ISSN-L)
- OpenAlex
- W3017669300
- Cited by
- 497
- References
- 20
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.