CoChat

Artificial intelligence for detecting electrolyte imbalance using electrocardiography

Open access
Kwon, Joon‐myoung, Jung, Min‐Seung, Kim, Kyung‐Hee, Jo, Yong‐Yeon, Shin, Jae‐Hyun, Cho, Yong‐Hyeon, Lee, Yoon‐Ji, Ban, Jang‐Hyeon, Jeon, Ki‐Hyun, Lee, Soo Youn, Park, Jinsik, Oh, Byung‐Hee · 2021 · Annals of Noninvasive Electrocardiology
Cited by 62

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Introduction: The detection and monitoring of electrolyte imbalance is essential for appropriate management of many metabolic diseases; however, there is no tool that detects such imbalances reliably and noninvasively. In this study, we developed a deep learning model (DLM) using electrocardiography (ECG) for detecting electrolyte imbalance and validated its performance in a multicenter study. Methods and Results: This retrospective cohort study included two hospitals: 92,140 patients who underwent a laboratory electrolyte examination and an ECG within 30 min were included in this study. A DLM was developed using 83,449 ECGs of 48,356 patients; the internal validation included 12,091 ECGs of 12,091 patients. We conducted an external validation with 31,693 ECGs of 31,693 patients from another hospital, and the result was electrolyte imbalance detection. During internal, the area under the receiving operating characteristic curve (AUC) of a DLM using a 12‐lead ECG for detecting hyperkalemia, hypokalemia, hypernatremia, hyponatremia, hypercalcemia, and hypocalcemia were 0.945, 0.866, 0.944, 0.885, 0.905, and 0.901, respectively. The values during external validation of the AUC of hyperkalemia, hypokalemia, hypernatremia, hyponatremia, hypercalcemia, and hypocalcemia were 0.873, 0.857, 0.839, 0.856, 0.831, and 0.813 respectively. The DLM helped to visualize the important ECG region for detecting each electrolyte imbalance, and it showed how the P wave, QRS complex, or T wave differs in importance in detecting each electrolyte imbalance. Conclusion: The proposed DLM demonstrated high performance in detecting electrolyte imbalance. These results suggest that a DLM can be used for detecting and monitoring electrolyte imbalance using ECG on a daily basis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/anec.12839

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 62

Metadata

Authors
Kwon, J., Jung, M., Kim, K., Jo, Y., Shin, J., Cho, Y., Lee, Y., Ban, J., Jeon, K., Lee, S. Y., Park, J., & Oh, B.
Venue
Annals of Noninvasive Electrocardiology
Publisher
Wiley
Published
2021-03-15
Volume
26
Issue
3
Pages
e12839-e12839
ISSN
  • 1082-720X (ISSN-L)
  • 1542-474X
OpenAlex
W3136766298
Cited by
62
References
10
FWCI
7.03
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial intelligence for detecting electrolyte imbalance using electrocardiography. https://app.cochat.ai/papers/10.1111/anec.12839
The paper
Kwon, J., Jung, M., Kim, K., Jo, Y., Shin, J., Cho, Y., Lee, Y., Ban, J., Jeon, K., Lee, S. Y., Park, J., & Oh, B. (2021). Artificial intelligence for detecting electrolyte imbalance using electrocardiography. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.12839

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.