CoChat

Continuous glucose monitoring in people with diabetes: the randomized controlled Glucose Level Awareness in Diabetes Study (GLADIS)

New, J. P., Ajjan, R., Pfeiffer, A. F. H., Freckmann, G. · 2015 · Diabetic Medicine
Cited by 80

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Aims: To investigate the best glucose monitoring strategy for maintaining euglycaemia by comparing self‐monitoring of blood glucose with continuous glucose monitoring, with or without an alarm function. Methods: A 100‐day, randomized controlled study was conducted at four European centres, enrolling 160 patients with Type 1 or Type 2 diabetes, on multiple daily insulin injections or continuous subcutaneous insulin infusion. Participants were randomized to continuous glucose monitoring without alarms (n = 48), continuous glucose monitoring with alarms (n = 49) or self‐monitoring of blood glucose (n = 48). Results: Time spent outside the glucose target during days 80–100 was 9.9 h/day for the continuous glucose monitoring without alarms group, 9.7 h/day for the continuous glucose monitoring with alarms group and 10.6 h/day for the self‐monitoring of blood glucose group (P = 0.18 and 0.08 compared with continuous glucose monitoring without and with alarms, respectively).The continuous glucose monitoring with alarms group spent less time in hypoglycaemia compared with the self‐monitoring of blood glucose group (1.0 h/day and 1.6 h/day, respectively; 95% CI −1.2 to −0.1; P = 0.030). Among those treated with continuous subcutaneous insulin infusion, time spent outside the glucose target was significantly different when comparing continuous glucose monitoring without alarms and self‐monitoring of blood glucose (−1.9 h/day; 95% CI −3.8 to 0.0; P = 0.0461) and when comparing continuous glucose monitoring with alarms and self‐monitoring of blood glucose (−2.4 h/day; 95% CI −4.1 to −0.5; P = 0.0134). There was no difference in HbA 1c reduction from baseline in the three groups; however, the proportion of participants with a reduction of ≥ 6 mmol/mol (≥ 0.5%) was higher in the continuous glucose monitoring without alarms (27%) and continuous glucose monitoring with alarms groups (25%) than in the self‐monitoring of blood glucose group (10.6%). Conclusions: This study shows that the use of continuous glucose monitoring reduces time spent outside glucose targets compared with self‐monitoring of blood glucose, especially among users of insulin pumps.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dme.12713

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
New, J. P., Ajjan, R., Pfeiffer, A. F. H., & Freckmann, G.
Venue
Diabetic Medicine
Publisher
Wiley
Published
2015-02-20
Volume
32
Issue
5
Pages
609-617
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W2030567268
Cited by
80
References
5
FWCI
6.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.