CoChat

Exenatide once weekly slows gastric emptying of solids and liquids in healthy, overweight people at steady‐state concentrations

Jones, Karen L., Huynh, Lian Q., Hatzinikolas, Seva, Rigda, Rachael S., Phillips, Liza K., Pham, Hung T., Marathe, Chinmay S., Wu, Tongzhi, Malbert, Charles H., Stevens, Julie E., Lange, Kylie, Rayner, Christopher K., Horowitz, Michael · 2020 · Diabetes, Obesity and Metabolism
Cited by 76

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Aims: To evaluate the effects of 8 weeks’ administration of exenatide (EXE) once weekly on gastric emptying of solids and liquids (using the “gold standard” technique, scintigraphy), glucose absorption and postprandial glycaemia in healthy people. Material and methods: A total of 32 healthy participants were randomized to receive either EXE once weekly (2 mg/wk subcutaneously; six men, 10 women, mean age 59.9 ± 0.9 years, mean body mass index [BMI] 29.6 ± 0.6 kg/m 2 ) or matching placebo (PBO; six men, 10 women, mean age 60.6 ± 1.2 years, mean BMI 29.5 ± 1.0 kg/m 2 ) for 8 weeks. Gastric emptying, nausea (visual analogue scale), and plasma glucose, insulin, C‐peptide and glucagon were measured for 120 min after a solid/liquid meal, comprising 100 g ground beef (radiolabelled with 20 MBq 99m Tc‐sulphur colloid) and 150 mL 10% glucose (radiolabelled with 7 MBq 67 Ga‐EDTA), and containing 5 g 3‐O‐methyl‐glucose (3‐OMG) as a marker of glucose absorption, at baseline and after 8 weeks’ treatment. Results: The study treatments were well tolerated. Scores for nausea were consistently low, with no difference between the EXE once weekly and PBO groups. EXE once weekly slowed gastric emptying of solids (area under the curve [AUC] 0–120min : P < 0.05) and liquids (AUC 0–120min : P = 0.01) substantially, and attenuated glucose absorption (3‐OMG incremental AUC [iAUC] 0–30min : P = 0.001) and the postprandial rise in plasma glucose (iAUC 0–30min : P = 0.008). Plasma glucagon at 2 h was reduced by EXE once weekly ( P = 0.001). The magnitude of the reduction in plasma glucose at t = 30 min from baseline to 8 weeks with EXE once weekly was related inversely to the 50% emptying time of the glucose drink ( r = −0.55, P = 0.03). Conclusions: In healthy participants, 8 weeks’ administration of the “long‐acting” glucagon‐like peptide‐1 receptor agonist EXE, slowed gastric emptying of solids and liquids substantially, with consequent reductions in glucose absorption and postprandial glycaemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/dom.13956

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

Metadata

Authors
Jones, K. L., Huynh, L. Q., Hatzinikolas, S., Rigda, R. S., Phillips, L. K., Pham, H. T., Marathe, C. S., Wu, T., Malbert, C. H., Stevens, J. E., Lange, K., Rayner, C. K., & Horowitz, M.
Venue
Diabetes, Obesity and Metabolism
Publisher
Wiley
Published
2020-01-28
Volume
22
Issue
5
Pages
788-797
ISSN
  • 1462-8902 (ISSN-L)
  • 1463-1326
OpenAlex
W2998516536
Cited by
76
References
19
FWCI
5.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.